CoChat

Ambulatory Blood Pressure and Cardiovascular Outcome in Relation to Perceived Sleep Deprivation

Open access
Verdecchia, Paolo, Angeli, Fabio, Borgioni, Claudia, Gattobigio, Roberto, Reboldi, Gianpaolo · 2007 · Hypertension
Cited by 133

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Sleep deprivation induced by cuff inflations during overnight blood pressure (BP) monitoring might interfere with the prognostic significance of nighttime BP. In 2934 initially untreated hypertensive subjects, we assessed the perceived quantity of sleep during overnight BP monitoring. Overall, 58.7%, 27.7%, 9.7%, and 4.0% of subjects reported a sleep duration perceived as usual (group A), <2 hours less than usual (group B), 2 to 4 hours less than usual (group C), and >4 hours less than usual (group D). Daytime BP did not differ across the groups (all P s not significant). Nighttime BP increased from group A to D (124/75, 126/76, 128/77, and 129/79 mm Hg, respectively; all P s for trend <0.01). Over a median follow-up period of 7 years there were 356 major cardiovascular events and 176 all-cause deaths. Incidence of total cardiovascular events and deaths was higher in the subjects with a night/day ratio in systolic BP >10% compared with those with a greater day–night BP drop in the group with perceived sleep duration as usual or <2 hours less than usual (both P <0.01), not in the group with duration of sleep ≥2 hours less than usual (all P s not significant). In a Cox model, the independent prognostic value of nighttime BP for total cardiovascular end points and all-cause mortality disappeared in the subjects with perceived sleep deprivation ≥2 hours. In conclusion, nighttime BP rises and loses its prognostic significance in the hypertensive subjects who perceive a sleep deprivation by ≥2 hours during overnight monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.0000258215.26755.20

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 26

  1. 10.1056/NEJMra060433 · DOI · Paper page
  2. 10.1161/hyp.35.3.844 · doi:10.1161/hyp.35.3.844
  3. 10.1001/jama.295.24.2859 · DOI · Paper page
  4. Parati G, Pomidossi G, Casadei R, Malaspina D, Colombo A, Ravogli A, Mancia G. Ambulatory blood pressure monitoring does not interfere with the haemodynamic effects of sleep. J Hypertens. 1985; 3: S107–S109.
  5. Degaute JP, van de Borne P, Kerkhofs M, Dramaix M, Linkowski P. Does non-invasive ambulatory blood pressure monitoring disturb sleep? J Hypertens. 1992; 10: 879–885.
  6. Lederbogen F, Schredl M, Weber-Hamann B, Kniest A, Heuser I, Deuschle M. Effect of ambulatory blood pressure measurement on sleep in patients with a major depressive episode. Blood Press Monit. 2003; 8: 187–190.
  7. 10.1136/bmj.308.6932.820 · DOI · Paper page
  8. 10.1016/S0140-6736(88)92867-X · DOI · Paper page
  9. 10.3109/08037059509077600 · DOI · Paper page
  10. 10.1097/00004872-199715110-00006 · DOI · Paper page
  11. 10.1016/S0895-7061(01)02143-4 · DOI · Paper page
  12. 10.1161/01.hyp.24.6.793 · DOI · Paper page
  13. 10.1016/S0895-7061(03)00912-9 · DOI
  14. 10.2337/diacare.20.7.1183 · DOI · Paper page
  15. Mora-Macia J, Ocon Pujadas J. Validation of a model of an automatic device for the ambulatory monitoring of blood pressure: the Spacelab 5200. Med Clin (Barc). 1992; 99: 314.
  16. 10.1097/00004872-198900076-00251 · DOI
  17. 10.1097/00004872-199106000-00016 · DOI · Paper page
  18. 10.1097/00004872-199605000-00003 · DOI · Paper page
  19. Verdecchia P, Schillaci G, Boldrini F, Porcellati C. Quantitative assessment of day-to-day spontaneous variability in non-invasive ambulatory blood pressure measurements in essential hypertension. J Hypertens. 1991; 9 (suppl 6): S322–S323.
  20. 10.1161/str.19.5.3363586 · doi:10.1161/str.19.5.3363586
  21. Cox DR. Regression models and life-tables. J R Stat Soc (B). 1972; 34: 187–220. · DOI · Paper page
  22. 10.1097/00004872-199202000-00013 · DOI
  23. 10.1161/hyp.33.5.1099 · doi:10.1161/hyp.33.5.1099
  24. 10.1097/00126097-200506000-00003 · DOI · Paper page
  25. 10.1161/01.hyp.0000120155.48024.6f · DOI
  26. 10.1161/01.HYP.0000226145.49783.a9 · DOI

Cited by

See all 133

Metadata

Authors
Verdecchia, P., Angeli, F., Borgioni, C., Gattobigio, R., & Reboldi, G.
Venue
Hypertension
Published
2007-04
Volume
49
Issue
4
Pages
777-783
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2021175971
Cited by
133
References
6
FWCI
8.64
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory Blood Pressure and Cardiovascular Outcome in Relation to Perceived Sleep Deprivation. https://app.cochat.ai/papers/10.1161/01.hyp.0000258215.26755.20
The paper
Verdecchia, P., Angeli, F., Borgioni, C., Gattobigio, R., & Reboldi, G. (2007). Ambulatory Blood Pressure and Cardiovascular Outcome in Relation to Perceived Sleep Deprivation. Hypertension. https://doi.org/10.1161/01.hyp.0000258215.26755.20

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.