Magnetic Resonance Angiography Versus Duplex Sonography for Diagnosing Renovascular Disease
Open accessThe DOI matches its Crossref record.
Abstract
Abstract —Noninvasive testing for renovascular disease is required to identify patients who may benefit from revascularization procedures without exposing an unnecessary amount of patients to the risks of catheter angiography. All available methods of diagnosing renal artery stenosis have significant limitations. We compared a new technique, contrast-enhanced magnetic resonance angiography, with an established technique, duplex ultrasonography, for the detection of renal artery stenosis using catheter angiography as the standard of reference. Eighty-nine patients with clinically suspected renovascular disease underwent duplex renal scanning and contrast-enhanced magnetic resonance angiography. Sixty of these also underwent catheter angiography. All studies were interpreted for the presence of renal artery stenosis blinded to the results of the other imaging modalities. For detection of hemodynamically significant (≥60% diameter reduction) main renal artery stenosis, sensitivity and specificity were 90% and 86%, respectively, for magnetic resonance angiography and 81% and 87% for duplex sonography. Most false readings involved differential grading of stenoses detected with all 3 techniques. When patients with fibromuscular dysplasia were excluded from the analysis, the sensitivity of magnetic resonance angiography increased to 97%, with a negative predictive value of 98%. Magnetic resonance angiography detected 96% and duplex 5% of accessory renal arteries seen at catheter angiography. Contrast-enhanced magnetic resonance angiography is a useful technique for diagnosing atherosclerotic renovascular disease. It overcomes the major limitations of duplex renal scanning. However, duplex has the advantage of providing hemodynamic information and appears better suited for the assessment of patients with suspected fibromuscular dysplasia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
“(50) Since variability is the rule rather than the exception, researchers should explore possible sources of heterogeneity in results, within the limits of the available sample size.”
Diagnosis, management, and future developments of fibromuscular dysplasia
Olin, J. W., & Sealove, B. A. (2011) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2010.10.066 · Cited by 275
Magnetic Resonance Angiography for the Diagnosis of Renal Artery Stenosis: A Meta-analysis
Tan, K. T., van Beek, E. J. R., Brown, P. W. G., van Delden, O. M., Tijssen, J., & Ramsay, L. E. (2002) · Clinical Radiology · doi:10.1053/crad.2002.0941 · Cited by 202
Willmann, J. K., Wildermuth, S., Pfammatter, T., Roos, J. E., Seifert, B., Hilfiker, P. R., Marincek, B., & Weishaupt, D. (2003) · Radiology · doi:10.1148/radiol.2271020014 · Cited by 197
Self-citationWilliams, G. J., Macaskill, P., Chan, S. F., Karplus, T. E., Yung, W., Hodson, E. M., & Craig, J. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0355 · Cited by 185
“[73]a 1999 89 24–83 X X 50.”
Ruehm, S. G., Hany, T. F., Pfammatter, T., Schneider, E., Ladd, M., & Debatin, J. F. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1741127 · Cited by 177
Self-citation
Metadata
- Authors
- Leung, D. A., Hoffmann, U., Pfammatter, T., Hany, T. F., Rainoni, L., Hilfiker, P., Schneider, E., Zimmermann-Paul, G. G., & Debatin, J. F.
- Venue
- Hypertension
- Published
- 1999-02
- Volume
- 33
- Issue
- 2
- Pages
- 726-731
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2153517233
- Cited by
- 112
- References
- 0
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.