Cholinergic Atrial Fibrillation in a Computer Model of a Two-Dimensional Sheet of Canine Atrial Cells With Realistic Ionic Properties
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Classical concepts of atrial fibrillation (AF) have been rooted in Moe’s multiple-wavelet hypothesis and simple cellular-automaton computer model. Recent experimental work has raised questions about the multiple-wavelet mechanism, suggesting a discrete “driver region” underlying AF. We reexplored the theoretical basis for AF with a 2-dimensional computer model of a 5×10-cm sheet of atrial cells with realistic ionic and coupling properties. Vagal actions were formulated based on patch-clamp studies of acetylcholine (ACh) effects. In control, a single extrastimulus resulted in a highly meandering unstable spiral wave. Simulated electrograms showed fibrillatory activity, with a dominant frequency (DF, 6.5 Hz) that correlated with the mean rate. Uniform ACh reduced core meander of the spiral wave by ≈70% (as measured by the standard deviation of spiral-wave tip position) and accelerated the DF to 17.0 Hz. Simulated vagally induced refractoriness heterogeneity caused wavefront breakup as accelerated reentrant activity in regions of short refractoriness impinged on regions unable to respond in a 1:1 fashion because of longer refractoriness. In 7 simulations spanning the range of conditions giving sustained AF, 5 were maintained by single dominant spiral waves. On average, 3.0±1.3 wavelets were present (range, 1 to 7). Most wavelets were short-lived and did not contribute to AF maintenance. In contrast to predictions of the multiple-wavelet hypothesis, but in agreement with recent experimental evidence, our model indicates that AF can result from relatively stable primary spiral-wave generators and is significantly organized. Our results suggest that vagal AF may arise from ACh-induced stabilization of the primary spiral-wave generator and disorganization of the heterogeneous tissue response. The full text of this article is available at http://www.circresaha.org.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
A computer model of atrial fibrillation
Moe, G. K., Rheinboldt, W. C., & Abildskov, J. A. (1964) · American Heart Journal · doi:10.1016/0002-8703(64)90371-0 · Cited by 1,342
Promotion of Atrial Fibrillation by Heart Failure in Dogs: Atrial Remodeling of a Different Sort
Li, D., Fareh, S., Leung, T. K., & Nattel, S. (1999) · Circulation · doi:10.1161/01.cir.100.1.87 · Cited by 1,341
Self-citationCourtemanche, M., Ramirez, R. J., & Nattel, S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.1.h301 · Cited by 1,218
Self-citationA Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency Ablation
Jai¨s, P., Hai¨ssaguerre, M., Shah, D. C., Chouairi, S., Gencel, L., Hocini, M., & Cle´menty, J. (1997) · Circulation · doi:10.1161/01.cir.95.3.572 · Cited by 1,117
Allessie, M. A., Bonke, F. I., & Schopman, F. J. (1977) · Circulation Research · doi:10.1161/01.res.41.1.9 · Cited by 1,066
Morillo, C. A., Klein, G. J., Jones, D. L., & Guiraudon, C. M. (1995) · Circulation · doi:10.1161/01.cir.91.5.1588 · Cited by 1,037
On the multiple wavelet hypothesis o f atrial fibrillation.
Moe, G. K. (1962) · Medical Entomology and Zoology · Cited by 913
The Mechanism and Graphic Registration of the Heart Beat.
(1925) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1925.02670230064033 · Cited by 818
Ionic Remodeling Underlying Action Potential Changes in a Canine Model of Atrial Fibrillation
Yue, L., Feng, J., Gaspo, R., Li, G.-R., Wang, Z., & Nattel, S. (1997) · Circulation Research · doi:10.1161/01.res.81.4.512 · Cited by 813
Self-citation
Cited by
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
“(296) have demonstrated that ACh can sta-”
Atrial Remodeling and Atrial Fibrillation: Mechanisms and Implications
Nattel, S., Burstein, B., & Dobrev, D. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.107.754564 · Cited by 1,124
Self-citationNattel, S., Maguy, A., Le Bouter, S., & Yeh, Y.-H. (2007) · Physiological Reviews · doi:10.1152/physrev.00014.2006 · Cited by 858
Self-citationAtrial Fibrillation Pathophysiology: Implications for Management
Iwasaki, Y.-K., Nishida, K., Kato, T., & Nattel, S. (2011) · Circulation · doi:10.1161/circulationaha.111.019893 · Cited by 852
Self-citationAtrial Remodeling and Atrial Fibrillation
Nattel, S., & Harada, M. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.555 · Cited by 736
Self-citationDriver domains in persistent atrial fibrillation
Haissaguerre, M., Hocini, M., Denis, A., Shah, A. J., Komatsu, Y., Yamashita, S., Daly, M., Amraoui, S., Zellerhoff, S., Picat, M.-Q., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005421 · Cited by 734
Recent advances in the molecular pathophysiology of atrial fibrillation
Wakili, R., Voigt, N., Kääb, S., Dobrev, D., & Nattel, S. (2011) · Journal of Clinical Investigation · doi:10.1172/jci46315 · Cited by 545
Self-citationKalifa, J., Tanaka, K., Zaitsev, A. V., Warren, M., Vaidyanathan, R., Auerbach, D., Pandit, S., Vikstrom, K. L., Ploutz-Snyder, R., Talkachou, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.575340 · Cited by 414
Computational tools for modeling electrical activity in cardiac tissue
Vigmond, E. J., Hughes, M., Plank, G., & Leon, L. J. (2003) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2003.09.017 · Cited by 316
Self-citationPandit, S. V., Berenfeld, O., Anumonwo, J. M. B., Zaritski, R. M., Kneller, J., Nattel, S., & Jalife, J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.060459 · Cited by 247
“D model composed of canine atrial cells (Kneller et al., 2002).”
BackgroundSelf-citationMechanisms of Atrial Fibrillation: Lessons From Animal Models
Nattel, S., Shiroshita-Takeshita, A., Brundel, B. J. J. M., & Rivard, L. (2005) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2005.06.002 · Cited by 244
Self-citationCardiac Potassium Channel Subtypes: New Roles in Repolarization and Arrhythmia
Schmitt, N., Grunnet, M., & Olesen, S.-P. (2014) · Physiological Reviews · doi:10.1152/physrev.00022.2013 · Cited by 242
Noninvasive Panoramic Mapping of Human Atrial Fibrillation Mechanisms: A Feasibility Report
HAISSAGUERRE, M., HOCINI, M., SHAH, A. J., DERVAL, N., SACHER, F., JAIS, P., & DUBOIS, R. (2013) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12075 · Cited by 221
Lemola, K., Chartier, D., Yeh, Y.-H., Dubuc, M., Cartier, R., Armour, A., Ting, M., Sakabe, M., Shiroshita-Takeshita, A., Comtois, P., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.737023 · Cited by 213
Self-citationLocalized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation
Waldo, A. L. (2007) · Yearbook of Cardiology · doi:10.1016/s0145-4145(08)70275-2 · Cited by 193
Remodeling of cardiomyocyte ion channels in human atrial fibrillation
Dobrev, D., & Ravens, U. (2003) · Basic Research in Cardiology · doi:10.1007/s00395-003-0409-8 · Cited by 192
Sarmast, F. (2003) · Cardiovascular Research · doi:10.1016/s0008-6363(03)00540-6 · Cited by 171
Autonomic Mechanism to Explain Complex Fractionated Atrial Electrograms (CFAE)
LIN, J., SCHERLAG, B. J., ZHOU, J., LU, Z., PATTERSON, E., JACKMAN, W. M., LAZZARA, R., & PO, S. S. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00976.x · Cited by 170
Plank, G., Burton, R. A. B., Hales, P., Bishop, M., Mansoori, T., Bernabeu, M. O., Garny, A., Prassl, A. J., Bollensdorff, C., Mason, F., et al. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0056 · Cited by 158
“2006), two-dimensional sheets (Leon & Roberge 1990; Beaumont et al. 1998; Skouibine et al. 1999; Anderson & Trayanova 2001; Samie et al. 2001; Kneller et al. 2002; Weiss et al. 2005) and three-dimensional slabs (Vigmond & Leon 1999; Cherry et al.”
Vagal atrial fibrillation: What is it and should we treat it?
Carpenter, A., Frontera, A., Bond, R., Duncan, E., & Thomas, G. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.08.108 · Cited by 65
“Kneller and colleagues [42] used computer modelling based on the canine atrium to”
MethodCorrado, C., Williams, S., Karim, R., Plank, G., O’Neill, M., & Niederer, S. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.04.005 · Cited by 50
Metadata
- Authors
- Kneller, J., Zou, R., Vigmond, E. J., Wang, Z., Leon, L. J., & Nattel, S.
- Venue
- Circulation Research
- Published
- 2002-05-17
- Volume
- 90
- Issue
- 9
- Pages
- E73-87
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2110258428
- Cited by
- 288
- References
- 47
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.