The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Human Mesenchymal Stem Cells as a Gene Delivery System to Create Cardiac Pacemakers
Abstract
We tested the ability of human mesenchymal stem cells (hMSCs) to deliver a biological pacemaker to the heart. hMSCs transfected with a cardiac pacemaker gene, mHCN2, by electroporation expressed high levels of Cs + -sensitive current (31.1±3.8 pA/pF at −150 mV) activating in the diastolic potential range with reversal potential of −37.5±1.0 mV, confirming the expressed current as I f -like. The expressed current responded to isoproterenol with an 11-mV positive shift in activation. Acetylcholine had no direct effect, but in the presence of isoproterenol, shifted activation 15 mV negative. Transfected hMSCs influenced beating rate in vitro when plated onto a localized region of a coverslip and overlaid with neonatal rat ventricular myocytes. The coculture beating rate was 93±16 bpm when hMSCs were transfected with control plasmid (expressing only EGFP) and 161±4 bpm when hMSCs were expressing both EGFP+mHCN2 ( P <0.05). We next injected 10 6 hMSCs transfected with either control plasmid or mHCN2 gene construct subepicardially in the canine left ventricular wall in situ. During sinus arrest, all control (EGFP) hearts had spontaneous rhythms (45±1 bpm, 2 of right-sided origin and 2 of left). In the EGFP+mHCN2 group, 5 of 6 animals developed spontaneous rhythms of left-sided origin (rate=61±5 bpm; P <0.05). Moreover, immunostaining of the injected regions demonstrated the presence of hMSCs forming gap junctions with adjacent myocytes. These findings demonstrate that genetically modified hMSCs can express functional HCN2 channels in vitro and in vivo, mimicking overexpression of HCN2 genes in cardiac myocytes, and represent a novel delivery system for pacemaker genes into the heart or other electrical syncytia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liechty, K. W., MacKenzie, T. C., Shaaban, A. F., Radu, A., Moseley, A. B., Deans, R., Marshak, D. R., & Flake, A. W. (2000) · Nature Medicine · doi:10.1038/81395 · Cited by 1,215
Differentiation of Pluripotent Embryonic Stem Cells Into Cardiomyocytes
Boheler, K. R., Czyz, J., Tweedie, D., Yang, H.-T., Anisimov, S. V., & Wobus, A. M. (2002) · Circulation Research · doi:10.1161/01.res.0000027865.61704.32 · Cited by 737
Protein A, avidin, and biotin in immunohistochemistry.
Hsu, S. M., & Raine, L. (1981) · Journal of Histochemistry & Cytochemistry · doi:10.1177/29.11.6172466 · Cited by 641
Biological pacemaker created by gene transfer
Miake, J., Marbán, E., & Nuss, H. B. (2002) · Nature · doi:10.1038/419132b · Cited by 421
Moosmang, S., Stieber, J., Zong, X., Biel, M., Hofmann, F., & Ludwig, A. (2001) · European Journal of Biochemistry · doi:10.1046/j.1432-1033.2001.02036.x · Cited by 415
Stone, G. W., Rogers, C., Hermiller, J., Feldman, R., Hall, P., Haber, R., Masud, A., Cambier, P., Caputo, R. P., Turco, M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000080894.51311.0a · Cited by 384
Xu, S.-Z., & Beech, D. J. (2001) · Circulation Research · doi:10.1161/01.res.88.1.84 · Cited by 361
A study of the ionic nature of the pace‐maker current in calf Purkinje fibres.
DiFrancesco, D. (1981) · The Journal of Physiology · doi:10.1113/jphysiol.1981.sp013714 · Cited by 343
Zhou, Y.-Y., Wang, S.-Q., Zhu, W.-Z., Chruscinski, A., Kobilka, B. K., Ziman, B., Wang, S., Lakatta, E. G., Cheng, H., & Xiao, R.-P. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.1.h429 · Cited by 280
Efficient Transfection Method for Primary Cells
Hamm, A., Krott, N., Breibach, I., Blindt, R., & Bosserhoff, A. K. (2002) · Tissue Engineering · doi:10.1089/107632702753725003 · Cited by 271
Cited by
Genesis and Regulation of the Heart Automaticity
Mangoni, M. E., & Nargeot, J. (2008) · Physiological Reviews · doi:10.1152/physrev.00018.2007 · Cited by 600
The Role of the Funny Current in Pacemaker Activity
DiFrancesco, D. (2010) · Circulation Research · doi:10.1161/circresaha.109.208041 · Cited by 587
Xue, T., Cho, H. C., Akar, F. G., Tsang, S.-Y., Jones, S. P., Marbán, E., Tomaselli, G. F., & Li, R. A. (2005) · Circulation · doi:10.1161/01.cir.0000151313.18547.a2 · Cited by 480
Molecular Architecture of the Human Sinus Node: Insights Into the Function of the Cardiac Pacemaker
Chandler, N. J., Greener, I. D., Tellez, J. O., Inada, S., Musa, H., Molenaar, P., DiFrancesco, D., Baruscotti, M., Longhi, R., Anderson, R. H., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.804369 · Cited by 396
Next-generation pacemakers: from small devices to biological pacemakers
Cingolani, E., Goldhaber, J. I., & Marbán, E. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.165 · Cited by 194
Metadata
- Authors
- Potapova, I., Plotnikov, A., Lu, Z., Danilo, P., Valiunas, V., Qu, J., Doronin, S., Zuckerman, J., Shlapakova, I. N., Gao, J., Pan, Z., Herron, A. J., Robinson, R. B., Brink, P. R., Rosen, M. R., & Cohen, I. S.
- Venue
- Circulation Research
- Published
- 2004-04-16
- Volume
- 94
- Issue
- 7
- Pages
- 952-959
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2131862797
- Cited by
- 285
- References
- 24
- FWCI
- 20.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Mesenchymal Stem Cells as a Gene Delivery System to Create Cardiac Pacemakers. https://app.cochat.ai/papers/10.1161/01.res.0000123827.60210.72
- The paper
- Potapova, I., Plotnikov, A., Lu, Z., Danilo, P., Valiunas, V., Qu, J., Doronin, S., Zuckerman, J., Shlapakova, I. N., Gao, J., Pan, Z., Herron, A. J., Robinson, R. B., Brink, P. R., Rosen, M. R., & Cohen, I. S. (2004). Human Mesenchymal Stem Cells as a Gene Delivery System to Create Cardiac Pacemakers. Circulation Research. https://doi.org/10.1161/01.res.0000123827.60210.72
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.