Heart Valve Tissue Engineering
Open accessThe DOI matches its Crossref record; 96 of the 96 references it cites were found in a registry or an index.
Abstract
Tissue-engineered heart valves have been proposed by physicians and scientists alike to be the ultimate solution for treating valvular heart disease. Rather than replacing a diseased or defective native valve with a mechanical or animal tissue–derived artificial valve, a tissue-engineered valve would be a living organ, able to respond to growth and physiological forces in the same way that the native aortic valve does. Two main approaches have been attempted over the past 10 to 15 years: regeneration and repopulation. Regeneration involves the implantation of a resorbable matrix that is expected to remodel in vivo and yield a functional valve composed of the cells and connective tissue proteins of the patient. Repopulation involves implanting a whole porcine aortic valve that has been previously cleaned of all pig cells, leaving an intact, mechanically sound connective tissue matrix. The cells of the patients are expected to repopulate and revitalize the acellular matrix, creating living tissue that already has the complex microstructure necessary for proper function and durability. Regrettably, neither of the 2 approaches has fared well in animal experiments, and the only clinical experience with tissue-engineered valves resulted in a number of early failures and patient death. This article reviews the technological details of the 2 main approaches, their rationale, their strengths and weaknesses, and the likely mechanisms for their failure. Alternative approaches to valvular tissue engineering, as well as the role of industry in shaping this field in the future, are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Rheinwatd, J. G., & Green, H. (1975) · Cell · doi:10.1016/s0092-8674(75)80001-8 · Cited by 4,537
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Bell, E., Ivarsson, B., & Merrill, C. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.3.1274 · Cited by 2,067
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Growth of cultured human epidermal cells into multiple epithelia suitable for grafting.
Green, H., Kehinde, O., & Thomas, J. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.11.5665 · Cited by 1,250
Fibroblasts, myofibroblasts, and wound contraction
Grinnell, F. (1994) · The Journal of cell biology · doi:10.1083/jcb.124.4.401 · Cited by 1,145
Fibroblast biology in three-dimensional collagen matrices
Grinnell, F. (2003) · Trends in Cell Biology · doi:10.1016/s0962-8924(03)00057-6 · Cited by 819
Calcification of Tissue Heart Valve Substitutes: Progress Toward Understanding and Prevention
Schoen, F. J., & Levy, R. J. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.06.033 · Cited by 725
Molecular Regulation of Atrioventricular Valvuloseptal Morphogenesis
Eisenberg, L. M., & Markwald, R. R. (1995) · Circulation Research · doi:10.1161/01.res.77.1.1 · Cited by 648
Cited by
3D Bioprinting of heterogeneous aortic valve conduits with alginate/gelatin hydrogels
Duan, B., Hockaday, L. A., Kang, K. H., & Butcher, J. T. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34420 · Cited by 1,002
Mikos, A. G., Herring, S. W., Ochareon, P., Elisseeff, J., Lu, H. H., Kandel, R., Schoen, F. J., Toner, M., Mooney, D., Atala, A., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3307 · Cited by 598
Atala, A., Kasper, F. K., & Mikos, A. G. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004890 · Cited by 544
Schoen, F. J. (2008) · Circulation · doi:10.1161/circulationaha.108.805911 · Cited by 421
Tissue Engineering Based on Cell Sheet Technology
Matsuda, N., Shimizu, T., Yamato, M., & Okano, T. (2007) · Advanced Materials · doi:10.1002/adma.200701978 · Cited by 398
Biomaterials in cardiac tissue engineering: Ten years of research survey
Chen, Q.-Z., Harding, S. E., Ali, N. N., Lyon, A. R., & Boccaccini, A. R. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.08.001 · Cited by 382
Heart Valve Tissue Engineering: Concepts, Approaches, Progress, and Challenges
Mendelson, K., & Schoen, F. J. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9163-z · Cited by 328
Liao, J., Joyce, E. M., & Sacks, M. S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.007 · Cited by 304
Clinical Application of Tissue Engineered Human Heart Valves Using Autologous Progenitor Cells
Cebotari, S., Lichtenberg, A., Tudorache, I., Hilfiker, A., Mertsching, H., Leyh, R., Breymann, T., Kallenbach, K., Maniuc, L., Batrinac, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.001065 · Cited by 299
Biomechanical properties of native and tissue engineered heart valve constructs
Hasan, A., Ragaert, K., Swieszkowski, W., Selimović, Š., Paul, A., Camci-Unal, G., Mofrad, M. R. K., & Khademhosseini, A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.023 · Cited by 279
Bioengineering Challenges for Heart Valve Tissue Engineering
Sacks, M. S., Schoen, F. J., & Mayer, J. E. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124903 · Cited by 256
Insights Into Degenerative Aortic Valve Disease
Goldbarg, S. H., Elmariah, S., Miller, M. A., & Fuster, V. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.024 · Cited by 233
Lincoln, J., Lange, A. W., & Yutzey, K. E. (2006) · Developmental Biology · doi:10.1016/j.ydbio.2006.03.027 · Cited by 231
Cell delivery in regenerative medicine: The cell sheet engineering approach
Yang, J., Yamato, M., Nishida, K., Ohki, T., Kanzaki, M., Sekine, H., Shimizu, T., & Okano, T. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.06.022 · Cited by 215
Mendoza-Novelo, B., Avila, E. E., Cauich-Rodríguez, J. V., Jorge-Herrero, E., Rojo, F. J., Guinea, G. V., & Mata-Mata, J. L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.017 · Cited by 196
Heart muscle engineering: An update on cardiac muscle replacement therapy
ZIMMERMANN, W., DIDIE, M., DOKER, S., MELNYCHENKO, I., NAITO, H., ROGGE, C., TIBURCY, M., & ESCHENHAGEN, T. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.03.023 · Cited by 169
Potential impact of the non‐human sialic acid N‐glycolylneuraminic acid on transplant rejection risk
Padler‐Karavani, V., & Varki, A. (2011) · Xenotransplantation · doi:10.1111/j.1399-3089.2011.00622.x · Cited by 162
Flanagan, T. C., Sachweh, J. S., Frese, J., Schnöring, H., Gronloh, N., Koch, S., Tolba, R. H., Schmitz-Rode, T., & Jockenhoevel, S. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0018 · Cited by 160
Matrix-dependent adhesion of vascular and valvular endothelial cells in microfluidic channels
Young, E. W. K., Wheeler, A. R., & Simmons, C. A. (2007) · Lab on a Chip · doi:10.1039/b712486d · Cited by 159
Outcome after aortic valve replacement in children: A systematic review and meta-analysis
Etnel, J. R. G., Elmont, L. C., Ertekin, E., Mokhles, M. M., Heuvelman, H. J., Roos-Hesselink, J. W., de Jong, P. L., Helbing, W. A., Bogers, A. J. J. C., & Takkenberg, J. J. M. (2016) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2015.09.083 · Cited by 140
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
The use of thermal techniques for the characterization and selection of natural biomaterials
Samouillan, V., Delaunay, F., Dandurand, J., Merbahi, N., Gardou, J.-P., Yousfi, M., Gandaglia, A., Spina, M., & Lacabanne, C. (2011) · Journal of Functional Biomaterials · doi:10.3390/jfb2030230 · Cited by 111
Bayrak, A., Tyralla, M., Ladhoff, J., Schleicher, M., Stock, U. A., Volk, H.-D., & Seifert, M. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.120 · Cited by 96
A sterilization method for decellularized xenogeneic cardiovascular scaffolds
Fidalgo, C., Iop, L., Sciro, M., Harder, M., Mavrilas, D., Korossis, S., Bagno, A., Palù, G., Aguiari, P., & Gerosa, G. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.035 · Cited by 71
Bastian, F., Stelzmüller, M.-E., Kratochwill, K., Kasimir, M.-T., Simon, P., & Weigel, G. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.005 · Cited by 47
Vinci, M. C., Tessitore, G., Castiglioni, L., Prandi, F., Soncini, M., Santoro, R., Consolo, F., Colazzo, F., Micheli, B., Sironi, L., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064769 · Cited by 42
Liu, C., Qiao, W., Cao, H., Dai, J., Li, F., Shi, J., & Dong, N. (2020) · Biomaterials Science · doi:10.1039/c9bm01956a · Cited by 38
Dalgliesh, A. J., Liu, Z. Z., & Griffiths, L. G. (2017) · Tissue Engineering Part A · doi:10.1089/ten.tea.2016.0405 · Cited by 7
Metadata
- Authors
- Vesely, I.
- Venue
- Circulation Research
- Published
- 2005-10-14
- Volume
- 97
- Issue
- 8
- Pages
- 743-755
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2028624725
- Cited by
- 309
- References
- 96
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.