The DOI matches its Crossref record.
Relationship between blood flow direction and endothelial cell orientation at arterial branch sites in rabbits and mice.
Open accessAbstract
The orientation of endothelial cells near arterial branch sites has been compared with flow streamlines near the arterial wall. We detected cell orientation by examining cell impressions in vascular casts of rabbit and mouse arterial branch sites. Flow streamlines were assessed in glass models with flow parameters approximating mean in vivo values. At high Reynolds numbers (large arteries), secondary flow develop near branch sites, and this was reflected in the pattern of streamlines near the vessel wall. At symmetrical Y bifurcations, streamlines originating near the inner wall of the branches are directed toward the lateral wall; thus they appear to wind around the daughter vessels and merge on the lateral wall. A similar phenomenon was observed on a 90 degree side branch. When flow conditions in the Y bifurcation and side branch models approximated those at the iliac bifurcation and renal artery origin, respectively, the streamlines near the walls were almost identical to the patterns of endothelial cell orientation. At very low Reynolds numbers, no secondary flow phenomena occurred and streamlines followed branch geometry. This mimicked endothelial cell orientation in very small vessels. Hence the influence of mean blood flow on endothelial cell was well predicted by the model studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cardiac Malformation in Neonatal Mice Lacking Connexin43
Reaume, A. G., de Sousa, P. A., Kulkarni, S., Langille, B. L., Zhu, D., Davies, T. C., Juneja, S. C., Kidder, G. M., & Rossant, J. (1995) · Science · doi:10.1126/science.7892609 · Cited by 1,244
Self-citationPiezo1 integration of vascular architecture with physiological force
Li, J., Hou, B., Tumova, S., Muraki, K., Bruns, A., Ludlow, M. J., Sedo, A., Hyman, A. J., McKeown, L., Young, R. S., et al. (2014) · Nature · doi:10.1038/nature13701 · Cited by 1,223
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Turbulent fluid shear stress induces vascular endothelial cell turnover in vitro.
Davies, P. F., Remuzzi, A., Gordon, E. J., Dewey, C. F., & Gimbrone, M. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.7.2114 · Cited by 847
Metadata
- Authors
- Langille, B. L., & Adamson, S. L.
- Venue
- Circulation Research
- Published
- 1981-04
- Volume
- 48
- Issue
- 4
- Pages
- 481-488
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1982383521
- Cited by
- 219
- References
- 0
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship between blood flow direction and endothelial cell orientation at arterial branch sites in rabbits and mice. https://app.cochat.ai/papers/10.1161/01.res.48.4.481
- The paper
- Langille, B. L., & Adamson, S. L. (1981). Relationship between blood flow direction and endothelial cell orientation at arterial branch sites in rabbits and mice. Circulation Research. https://doi.org/10.1161/01.res.48.4.481
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.