Electrotonically mediated delayed conduction and reentry in relation to "slow responses" in mammalian ventricular conducting tissue.
Open accessThe DOI matches its Crossref record.
Abstract
A narrow zone of block in isolated false tendon preparations was created by perfusion of the central compartment (gap) of a three-compartment tissue bath with either an isotonic sucrose solution or a solution designed to mimic the extracellular milieu in ischemic tissue. Driven responses on the proximal side of the gap were transmitted to the distal side after long delays. The characteristics of the "ischemic" gap model were found to be qualitatively similar to those of the sucrose gap model in which impulse transmission is electrotonically mediated. In both models, the effects of driven action potentials were mimicked by electrotonic displacement of membrane potential by current pulses passed across the gap. Foot-potentials representative of electrotonic potentials bringing the distal membrane to threshold were present in all cases and were found to be largely unaffected by the slow channel-blocking agent, verapamil. Transmembrane activity recorded from the central portion of the gap segment was shown to be electrotonic in nature. Ectopic activity in the form of reflected reentry was readily demonstrable in the ischemic gap model in the presence or absence of verapamil as well as in the sucrose gap model. When propagation across the gap was mediated by "slow" responses, transmission was relatively prompt and reentry did not occur. Our observations suggest that very slow conduction through ischemic areas may result from step delays imposed by electrotonic transmission of impulses across inexcitable segments of cable rather than from uniform slow conduction of propagated action potentials with slow upstrokes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overview of Basic Mechanisms of Cardiac Arrhythmia
Antzelevitch, C., & Burashnikov, A. (2011) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2010.10.012 · Cited by 464
Self-citationMechanisms of cardiac arrhythmias
Tse, G. (2016) · Journal of Arrhythmia · doi:10.1016/j.joa.2015.11.003 · Cited by 269
“extracellular milieu that is present during ischemia [57].”
BackgroundInitiating Reentry: The Role of Nonuniform Anisotropy in Small Circuits
SPACH, M. S., & JOSEPHSON, M. E. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01157.x · Cited by 266
Current status of monophasic action potential recording: theories, measurements and interpretations
Franz, M. (1999) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00268-5 · Cited by 173
Lesh, M. D., Pring, M., & Spear, J. F. (1989) · Circulation Research · doi:10.1161/01.res.65.5.1426 · Cited by 171
Animal models of ventricular arrhythmias
Hamlin, R. L. (2007) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2006.08.006 · Cited by 60
Metadata
- Authors
- Antzelevitch, C., & Moe, G. K.
- Venue
- Circulation Research
- Published
- 1981-11
- Volume
- 49
- Issue
- 5
- Pages
- 1129-1139
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2051176285
- Cited by
- 89
- References
- 0
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.