Restricted distribution of connexin40, a gap junctional protein, in mammalian heart.
The DOI matches its Crossref record.
Abstract
Connexin40 (Cx40) is a member of the connexin family of gap junction proteins. Its mRNA, abundant in lung, is also present in mammalian heart, although in lower amount. Rabbit antipeptide antibodies directed to the COOH terminus (residues 335 to 356) of rat Cx40 were characterized to investigate the distribution of Cx40 in rat and guinea pig cardiac tissues. The affinity-purified antibodies detect specifically a major protein (M(r), 40,000) in immunoblots of total extracts from rat lung and rat and guinea pig heart. In sections of guinea pig atrial tissue treated for immunofluorescence, a strong labeling associated with myocytes was seen with a distribution consistent with that of intercalated disks. The results of immunoelectron microscopy carried out with guinea pig atrial tissue showed that epitopes recognized by these antibodies were exclusively associated with gap junctions. These results, added to those of control experiments, demonstrate that antibodies 335-356 are specific for Cx40. Double-labeling experiments carried out with lung sections using anti-factor VIII and anti-Cx40 antibodies suggest that Cx40 is expressed in blood vessel endothelial cells. In guinea pig and rat heart sections, investigated using both immunofluorescence and immunoperoxidase techniques, a signal was also found to be associated with vascular walls. In guinea pig heart, only atrial myocytes are Cx40-positive. No labeling was detected in ventricular myocytes, including those of the His bundle and the bundle branches, which otherwise do express connexin43 (Cx43). In rat heart Cx40-expressing myocytes are localized in branches, and the Purkinje fibers. Cx43 is not detected either in the His bundle or in the proximal parts of the bundle branches, and consequently, Cx40 is the first connexin demonstrated in this region of the rat conduction system. Cx40 was not detected in the working ventricular myocytes. Double-labeling experiments carried out with hen anti-Cx43 antibodies and rabbit anti-Cx40 antibodies demonstrated that, in tissues expressing both Cx43 and Cx40, these two connexins were localized in the same immunoreactive sites. A few sites, however, appear to contain only one or the other of these two connexins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Connections with Connexins: the Molecular Basis of Direct Intercellular Signaling
Bruzzone, R., White, T. W., & Paul, D. L. (1996) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1996.0001q.x · Cited by 1,302
Cardiac Malformation in Neonatal Mice Lacking Connexin43
Reaume, A. G., de Sousa, P. A., Kulkarni, S., Langille, B. L., Zhu, D., Davies, T. C., Juneja, S. C., Kidder, G. M., & Rossant, J. (1995) · Science · doi:10.1126/science.7892609 · Cited by 1,244
Plasma Membrane Channels Formed by Connexins: Their Regulation and Functions
SÁEZ, J. C., BERTHOUD, V. M., BRAÑES, M. C., MARTÍNEZ, A. D., & BEYER, E. C. (2003) · Physiological Reviews · doi:10.1152/physrev.00007.2003 · Cited by 1,170
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
“Cx40 plays an important role in the atria, the atrioventricular node, and the specific ventricular conducting system (15, 39, 64, 120, 121, 289).”
BackgroundRemodelling of gap junctions and connexin expression in diseased myocardium
Severs, N. J., Bruce, A. F., Dupont, E., & Rothery, S. (2008) · Cardiovascular Research · doi:10.1093/cvr/cvn133 · Cited by 560
Schram, G., Pourrier, M., Melnyk, P., & Nattel, S. (2002) · Circulation Research · doi:10.1161/01.res.0000018627.89528.6f · Cited by 427
Gap Junctions in Cardiovascular Disease
Jongsma, H. J., & Wilders, R. (2000) · Circulation Research · doi:10.1161/01.res.86.12.1193 · Cited by 403
Self-citationGENETIC DISEASES AND GENE KNOCKOUTS REVEAL DIVERSE CONNEXIN FUNCTIONS
White, T. W., & Paul, D. L. (1999) · Annual Review of Physiology · doi:10.1146/annurev.physiol.61.1.283 · Cited by 392
Nielsen, M. S., Nygaard Axelsen, L., Sorgen, P. L., Verma, V., Delmar, M., & Holstein‐Rathlou, N. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110051 · Cited by 386
Simon, A. M., Goodenough, D. A., & Paul, D. L. (1998) · Current Biology · doi:10.1016/s0960-9822(98)70113-7 · Cited by 385
Slow ventricular conduction in mice heterozygous for a connexin43 null mutation.
Guerrero, P. A., Schuessler, R. B., Davis, L. M., Beyer, E. C., Johnson, C. M., Yamada, K. A., & Saffitz, J. E. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119367 · Cited by 314
Altered Connexin Expression in Human Congestive Heart Failure
Dupont, E., Matsushita, T., Kaba, R. A., Vozzi, C., Coppen, S. R., Khan, N., Kaprielian, R., Yacoub, M. H., & Severs, N. J. (2001) · Journal of Molecular and Cellular Cardiology · doi:10.1006/jmcc.2000.1308 · Cited by 312
Hagendorff, A., Schumacher, B., Kirchhoff, S., Lüderitz, B., & Willecke, K. (1999) · Circulation · doi:10.1161/01.cir.99.11.1508 · Cited by 309
Gap junction alterations in human cardiac disease
Severs, N. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2003.12.007 · Cited by 294
Effects of chronic atrial fibrillation on gap junction distribution in human and rat atria
Polontchouk, L., Haefliger, J.-A., Ebelt, B., Schaefer, T., Stuhlmann, D., Mehlhorn, U., Kuhn-Regnier, F., De Vivie, E. R., & Dhein, S. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01443-7 · Cited by 292
Development of the Cardiac Conduction System
Moorman, A. F. M., de Jong, F., Denyn, M. M. F. J., & Lamers, W. H. (1998) · Circulation Research · doi:10.1161/01.res.82.6.629 · Cited by 290
Self-citationThe Cardiomyocyte Circadian Clock: Emerging Roles in Health and Disease
Durgan, D. J., & Young, M. E. (2010) · Circulation Research · doi:10.1161/circresaha.109.209957 · Cited by 277
Thomas, S. A., Schuessler, R. B., Berul, C. I., Beardslee, M. A., Beyer, E. C., Mendelsohn, M. E., & Saffitz, J. E. (1998) · Circulation · doi:10.1161/01.cir.97.7.686 · Cited by 248
“muscle and components of the specialized cardiac conduction system.(8,9,14) The identical atrial conduction velocities observed in Cx43 and 1/1 mice suggest that the presence of Cx40 can”
BackgroundLi, J., Patel, V. V., Kostetskii, I., Xiong, Y., Chu, A. F., Jacobson, J. T., Yu, C., Morley, G. E., Molkentin, J. D., & Radice, G. L. (2005) · Circulation Research · doi:10.1161/01.res.0000181132.11393.18 · Cited by 223
Gourdie, R. G., Mima, T., Thompson, R. P., & Mikawa, T. (1995) · Development · doi:10.1242/dev.121.5.1423 · Cited by 217
Gap Junction Protein Phenotypes of the Human Heart and Conduction System
DAVIS, L. M., RODEFELD, M. E., GREEN, K., BEYER, E. C., & SAFFITZ, J. E. (1995) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1995.tb00357.x · Cited by 216
Altered Pattern of Vascular Connexin Expression in Atherosclerotic Plaques
Kwak, B. R., Mulhaupt, F., Veillard, N., Gros, D. B., & Mach, F. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/hq0102.104125 · Cited by 213
Self-citationDelorme, B., Dahl, E., Jarry‐guichard, T., Marics, I., Briand, J., Willecke, K., Gros, D., & Théveniau‐Ruissy, M. (1995) · Developmental Dynamics · doi:10.1002/aja.1002040403 · Cited by 173
Self-citationElectrophysiological features of the mouse sinoatrial node in relation to connexin distribution
Verheijck, E. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(01)00364-9 · Cited by 172
Metadata
- Authors
- Gros, D., Jarry-Guichard, T., Ten Velde, I., de Maziere, A., van Kempen, M. J., Davoust, J., Briand, J. P., Moorman, A. F., & Jongsma, H. J.
- Venue
- Circulation Research
- Published
- 1994-05
- Volume
- 74
- Issue
- 5
- Pages
- 839-851
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2144556755
- Cited by
- 219
- References
- 0
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.