CoChat

Chronic Inhalation of Nitric Oxide Inhibits Neointimal Formation After Balloon-Induced Arterial Injury

Lee, Joon S., Adrie, Christophe, Jacob, Howard J., Roberts, Jesse D., Zapol, Warren M., Bloch, Kenneth D. · 1996 · Circulation Research
Cited by 113

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Abstract Systemic and local intravascular NO administration inhibits neointimal formation after vascular injury in animal models. NO appears to attenuate smooth muscle proliferation both directly and indirectly by preventing the release of growth factors. Inhalation of low concentrations of NO dilates pulmonary vascular smooth muscle but does not cause systemic vasodilatation. Recently, NO inhalation was found to inhibit platelet function in vivo. We studied the effects of NO inhalation on neointimal formation after balloon-induced injury of the adult rat carotid artery. Beginning 60 minutes before carotid injury, rats breathed either air with 0 or 80 ppm NO for 14 days. Rats were killed, carotid arteries were fixed and paraffin-embedded, and neointimal formation was measured by analyzing the ratio of intimal to medial areas (I/M ratio) in carotid artery cross sections. Intimal hyperplasia was evident in both groups of animals, but I/M ratios were 43% less in animals breathing 80 ppm NO for 2 weeks than in animals breathing air alone (0.78±0.12 and 1.37±0.11 [mean±SE], respectively; P <.02). Similarly, 1 week after carotid injury, neointimal formation was less in rats breathing 80 ppm NO than in rats breathing air alone (I/M ratio, 0.39±0.11 versus 0.76±0.06; P <.02). Breathing 20 ppm NO for 2 weeks or 80 ppm NO for 1 week followed by air alone for 1 week did not attenuate neointimal formation measured at 14 days. In anesthetized rats breathing 80 ppm NO or air alone for 1 hour, neither systemic blood pressure nor bleeding time differed. These observations demonstrate that inhaling 80 ppm NO inhibits neointimal formation after balloon-induced carotid artery injury in rats. NO inhalation may represent a safe and novel method of preventing restenosis after percutaneous angioplasty.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.78.2.337

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 113

Metadata

Authors
Lee, J. S., Adrie, C., Jacob, H. J., Roberts, J. D., Zapol, W. M., & Bloch, K. D.
Venue
Circulation Research
Published
1996-02
Volume
78
Issue
2
Pages
337-342
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2124270277
Cited by
113
References
3
FWCI
9.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.