The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Identification of Distinct Luminal Domains for Macromolecules, Erythrocytes, and Leukocytes Within Mammalian Capillaries
Abstract
A thick endothelial surface coat consisting of the glycocalyx and associated plasma proteins has been hypothesized to reduce functional capillary volume available for flowing plasma macromolecules and blood cells. The purpose of this study was to compare anatomic and functional capillary diameters available for macromolecules, RBCs, and WBCs in hamster cremaster muscle capillaries. Bright-field and fluorescence microscopy provided similar estimates (mean±SE) of the anatomic capillary diameter: 5.1±0.1 μm (bright field, 39 capillaries in 10 animals) and 5.1±0.2 μm (membrane dye PKH26, 18 capillaries in 2 animals). Estimates of functional diameters were obtained by measuring the width of RBCs and WBCs and the intracapillary distribution of systemically injected fluorescein isothiocyanate (FITC)–dextran 70. WBCs (5.1±0.2 μm) fully occupied the anatomic capillary cross section. In contrast, the widths of RBCs (3.9±0.2 μm, 21 capillaries in 8 animals) and FITC-dextran (4.3±0.2 μm, 21 capillaries in 8 animals) were significantly smaller than the anatomic capillary diameter. Continuous (1- to 5-minute) excitation of fluorochromes in the capillary lumen (light-dye treatment) increased the width of RBCs passing the treated site from 3.6±0.3 to 4.4±0.3 μm (6 capillaries in 4 animals) and the width of the FITC-dextran column from 4.1±0.2 to 4.6±0.3 μm (10 capillaries in 7 animals). Furthermore, light-dye treatment increased capillary tube hematocrit by 60% in 40-μm-long capillary segments compared with untreated sites in the same capillaries. It is concluded that the wall of skeletal muscle capillaries is decorated with a 0.4- to 0.5-μm-thick endothelial surface coat, which may represent the true active interface between blood and the capillary wall.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MORPHOLOGICAL ASPECTS OF EXTRACELLULAR POLYSACCHARIDES
BENNETT, H. S. (1963) · Journal of Histochemistry & Cytochemistry · doi:10.1177/11.1.14 · Cited by 643
Resistance to blood flow in microvessels in vivo.
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994) · Circulation Research · doi:10.1161/01.res.75.5.904 · Cited by 616
Fine structures of capillary and endocapillary layer as revealed by ruthenium red.
Luft, J. H. (1966) · PubMed · Cited by 504
An open cremaster muscle preparation for the study of blood vessels by in vivo microscopy
Baez, S. (1973) · Microvascular Research · doi:10.1016/0026-2862(73)90054-x · Cited by 498
A fiber matrix model of capillary permeability
Curry, F. E., & Michel, C. C. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90024-2 · Cited by 391
Microvascular hematocrit and red cell flow in resting and contracting striated muscle
Klitzman, B., & Duling, B. R. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.4.h481 · Cited by 352
Self-citationMertens, G., Cassiman, J. J., Van den Berghe, H., Vermylen, J., & David, G. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)88721-5 · Cited by 242
Desjardins, C., & Duling, B. R. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.258.3.h647 · Cited by 221
Self-citationSchnitzer, J. E. (1992) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1992.262.1.h246 · Cited by 217
Role of heparan sulfate in immune system-blood vessel interactions
Ihrcke, N. S., Wrenshall, L. E., Lindman, B. J., & Platt, J. L. (1993) · Immunology Today · doi:10.1016/0167-5699(93)90265-m · Cited by 200
Endothelial cell gene expression in response to injury
Gerritsen, M. E., & Bloor, C. M. (1993) · The FASEB Journal · doi:10.1096/fasebj.7.6.8472891 · Cited by 191
Plasma proteins modify the endothelial cell glycocalyx of frog mesenteric microvessels.
Adamson, R. H., & Clough, G. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp018934 · Cited by 190
Bayer, M. E., & Thurow, H. (1977) · Journal of Bacteriology · doi:10.1128/jb.130.2.911-936.1977 · Cited by 173
Fåhraeus, R. (1928) · Journal of Molecular Medicine · doi:10.1007/bf01738786 · Cited by 132
Mechanics of fluid movement across single capillaries in the rabbit
Zweifach, B. W., & Intaglietta, M. (1968) · Microvascular Research · doi:10.1016/0026-2862(68)90008-3 · Cited by 131
Functions of the Endothelial Cell Surface
Simionescu, M., & Simionescu, N. (1986) · Annual Review of Physiology · doi:10.1146/annurev.ph.48.030186.001431 · Cited by 109
Specific albumin binding to microvascular endothelium in culture
Schnitzer, J. E., Carley, W. W., & Palade, G. E. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.3.h425 · Cited by 100
Damiano, E. R., Duling, B. R., Ley, K. F., & Skalak, T. C. (1996) · Journal of Fluid Mechanics · doi:10.1017/s0022112096000274 · Cited by 96
Self-citationTurner, M. R., Clough, G. F., & Michel, C. C. (1983) · Microvascular Research · doi:10.1016/0026-2862(83)90016-x · Cited by 95
Red blood cell mechanics and capillary blood rheology
Secomb, T. W. (1991) · Cell Biophysics · doi:10.1007/bf02989816 · Cited by 80
Permeability of single capillaries to intermediate-sized colored solutes
CURRY, F. E., Huxley, V. H., & Adamson, R. H. (1983) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1983.245.3.h495 · Cited by 51
Differentiation of light-dye effects in the microcirculation
Miller, F. N., Sims, D., Schuschke, D. A., & Abney, D. L. (1992) · Microvascular Research · doi:10.1016/0026-2862(92)90078-4 · Cited by 39
Determination of capillary tube hematocrit during arteriolar microperfusion
Keller, M. W., Damon, D. N., & Duling, B. R. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.266.6.h2229 · Cited by 28
Self-citationPiepkorn, M. W., Hovingh, P., & Linker, A. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91712-l · Cited by 14
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Self-citationSignaling Mechanisms Regulating Endothelial Permeability
Mehta, D., & Malik, A. B. (2006) · Physiological Reviews · doi:10.1152/physrev.00012.2005 · Cited by 1,720
Hemodynamic shear stress and the endothelium in cardiovascular pathophysiology
Davies, P. F. (2009) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1397 · Cited by 1,209
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
Metadata
- Authors
- Vink, H., & Duling, B. R.
- Venue
- Circulation Research
- Published
- 1996-09
- Volume
- 79
- Issue
- 3
- Pages
- 581-589
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2156156866
- Cited by
- 615
- References
- 24
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.