The DOI matches its Crossref record.
Novel Vascular Graft Grown Within Recipient’s Own Peritoneal Cavity
Open accessAbstract
Abstract —A method by which to overcome the clinical symptoms of atherosclerosis is the insertion of a graft to bypass an artery blocked or impeded by plaque. However, there may be insufficient autologous mammary artery for multiple or repeat bypass, saphenous vein may have varicose degenerative alterations that can lead to aneurysm in high-pressure sites, and small-caliber synthetic grafts are prone to thrombus induction and occlusion. Therefore, the aim of the present study was to develop an artificial blood conduit of any required length and diameter from the cells of the host for autologous transplantation. Silastic tubing, of variable length and diameter, was inserted into the peritoneal cavity of rats or rabbits. By 2 weeks, it had become covered by several layers of myofibroblasts, collagen matrix, and a single layer of mesothelium. The Silastic tubing was removed from the harvested implants, and the tube of living tissue was everted such that it now resembled a blood vessel with an inner lining of nonthrombotic mesothelial cells (the “intima”), with a “media” of smooth muscle–like cells (myofibroblasts), collagen, and elastin, and with an outer collagenous “adventitia.” The tube of tissue (10 to 20 mm long) was successfully grafted by end-to-end anastomoses into the severed carotid artery or abdominal aorta of the same animal in which they were grown. The transplant remained patent for at least 4 months and developed structures resembling elastic lamellae. The myofibroblasts gained a higher volume fraction of myofilaments and became responsive to contractile agonists, similar to the vessel into which they had been grafted. It is suggested that these nonthrombogenic tubes of living tissue, grown in the peritoneal cavity of the host, may be developed as autologous coronary artery bypass grafts or as arteriovenous access fistulae for hemodialysis patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shimizu, K., Sugiyama, S., Aikawa, M., Fukumoto, Y., Rabkin, E., Libby, P., & Mitchell, R. N. (2001) · Nature Medicine · doi:10.1038/89121 · Cited by 494
Chlupáč, J., Filová, E., & Bačáková, L. (2009) · Physiological Research · doi:10.33549/physiolres.931918 · Cited by 408
Tissue Engineering of Small Diameter Vascular Grafts
Teebken, O. E., & Haverich, A. (2002) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2002.1654 · Cited by 268
Tissue engineering of blood vessel
Zhang, W. J., Liu, W., Cui, L., & Cao, Y. (2007) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2007.00099.x · Cited by 217
Implant Fibrosis and the Underappreciated Role of Myofibroblasts in the Foreign Body Reaction
Noskovicova, N., Hinz, B., & Pakshir, P. (2021) · Cells · doi:10.3390/cells10071794 · Cited by 184
Metadata
- Authors
- Campbell, J. H., Efendy, J. L., & Campbell, G. R.
- Venue
- Circulation Research
- Published
- 1999-12-03
- Volume
- 85
- Issue
- 12
- Pages
- 1173-1178
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2103409893
- Cited by
- 293
- References
- 0
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel Vascular Graft Grown Within Recipient’s Own Peritoneal Cavity. https://app.cochat.ai/papers/10.1161/01.res.85.12.1173
- The paper
- Campbell, J. H., Efendy, J. L., & Campbell, G. R. (1999). Novel Vascular Graft Grown Within Recipient’s Own Peritoneal Cavity. Circulation Research. https://doi.org/10.1161/01.res.85.12.1173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.