Novel Vascular Graft Grown Within Recipient’s Own Peritoneal Cavity
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Abstract —A method by which to overcome the clinical symptoms of atherosclerosis is the insertion of a graft to bypass an artery blocked or impeded by plaque. However, there may be insufficient autologous mammary artery for multiple or repeat bypass, saphenous vein may have varicose degenerative alterations that can lead to aneurysm in high-pressure sites, and small-caliber synthetic grafts are prone to thrombus induction and occlusion. Therefore, the aim of the present study was to develop an artificial blood conduit of any required length and diameter from the cells of the host for autologous transplantation. Silastic tubing, of variable length and diameter, was inserted into the peritoneal cavity of rats or rabbits. By 2 weeks, it had become covered by several layers of myofibroblasts, collagen matrix, and a single layer of mesothelium. The Silastic tubing was removed from the harvested implants, and the tube of living tissue was everted such that it now resembled a blood vessel with an inner lining of nonthrombotic mesothelial cells (the “intima”), with a “media” of smooth muscle–like cells (myofibroblasts), collagen, and elastin, and with an outer collagenous “adventitia.” The tube of tissue (10 to 20 mm long) was successfully grafted by end-to-end anastomoses into the severed carotid artery or abdominal aorta of the same animal in which they were grown. The transplant remained patent for at least 4 months and developed structures resembling elastic lamellae. The myofibroblasts gained a higher volume fraction of myofilaments and became responsive to contractile agonists, similar to the vessel into which they had been grafted. It is suggested that these nonthrombogenic tubes of living tissue, grown in the peritoneal cavity of the host, may be developed as autologous coronary artery bypass grafts or as arteriovenous access fistulae for hemodialysis patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Myofibroblasts in an avascular fibrous tissue.
Ryan, G. B., Cliff, W. J., Gabbiani, G., Irlé, C., Statkov, P. R., & Majno, G. (1973) · PubMed · Cited by 103
Origin of myofibroblasts in the avascular capsule around free-floating intraperitoneal blood clots
CAMPBELL, G. R., & Ryan, G. B. (1983) · Pathology · doi:10.3109/00313028309083503 · Cited by 75
Self-citationVenous response to endothelial denudation
Manderson, J. A., & CAMPBELL, G. R. (1986) · Pathology · doi:10.3109/00313028609090832 · Cited by 40
Self-citationT Lymphocytes Affect Smooth Muscle Cell Phenotype and Proliferation
Rolfe, B. E., Campbell, J. H., Smith, N. J., Cheong, M. W., & CAMPBELL, G. R. (1995) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.15.8.1204 · Cited by 32
Self-citationMosse, P. R. L., CAMPBELL, G. R., & Ryan, G. B. (1985) · Pathology · doi:10.3109/00313028509105492 · Cited by 14
Self-citation
Cited by
Small-diameter vascular tissue engineering
Seifu, D. G., Purnama, A., Mequanint, K., & Mantovani, D. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.77 · Cited by 501
Shimizu, K., Sugiyama, S., Aikawa, M., Fukumoto, Y., Rabkin, E., Libby, P., & Mitchell, R. N. (2001) · Nature Medicine · doi:10.1038/89121 · Cited by 494
Chlupáč, J., Filová, E., & Bačáková, L. (2009) · Physiological Research · doi:10.33549/physiolres.931918 · Cited by 408
Biomaterials for Vascular Tissue Engineering
Ravi, S., & Chaikof, E. L. (2010) · Regenerative Medicine · doi:10.2217/rme.09.77 · Cited by 387
Tissue engineering: a 21st century solution to surgical reconstruction
Fuchs, J. R., Nasseri, B. A., & Vacanti, J. P. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)02820-x · Cited by 376
Immunomodulatory Biomaterials for Tissue Repair
Whitaker, R., Hernaez-Estrada, B., Hernandez, R. M., Santos-Vizcaino, E., & Spiller, K. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00895 · Cited by 338
Ullah, H., Wahid, F., Santos, H. A., & Khan, T. (2016) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2016.05.029 · Cited by 330
Elastin biosynthesis: The missing link in tissue-engineered blood vessels
PATEL, A., FINE, B., SANDIG, M., & MEQUANINT, K. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.02.021 · Cited by 328
Zhu, M., Li, W., Dong, X., Yuan, X., Midgley, A. C., Chang, H., Wang, Y., Wang, H., Wang, K., Ma, P. X., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12545-3 · Cited by 315
L'Heureux, N., Dusserre, N., Marini, A., Garrido, S., de la Fuente, L., & McAllister, T. (2007) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0930 · Cited by 292
Tissue Engineering of Small Diameter Vascular Grafts
Teebken, O. E., & Haverich, A. (2002) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2002.1654 · Cited by 268
Brinkman, W. T., Nagapudi, K., Thomas, B. S., & Chaikof, E. L. (2003) · Biomacromolecules · doi:10.1021/bm0257412 · Cited by 246
Seifalian, A. M., Tiwari, A., Hamilton, G., & Salacinski, H. J. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06841.x · Cited by 225
Tissue engineering of blood vessel
Zhang, W. J., Liu, W., Cui, L., & Cao, Y. (2007) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2007.00099.x · Cited by 217
Small-diameter biodegradable scaffolds for functional vascular tissue engineering in the mouse model
Roh, J. D., Nelson, G. N., Brennan, M. P., Mirensky, T. L., Yi, T., Hazlett, T. F., Tellides, G., Sinusas, A. J., Pober, J. S., Saltzman, W. M., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.041 · Cited by 192
“Tissue engineering and regenerative medicine have made significant progress toward the creation of autologous vascular grafts for the repair of damaged or malformed vessels [1–5].”
BackgroundKelm, J. M., Lorber, V., Snedeker, J. G., Schmidt, D., Broggini-Tenzer, A., Weisstanner, M., Odermatt, B., Mol, A., Zünd, G., & Hoerstrup, S. P. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.03.002 · Cited by 191
Implant Fibrosis and the Underappreciated Role of Myofibroblasts in the Foreign Body Reaction
Noskovicova, N., Hinz, B., & Pakshir, P. (2021) · Cells · doi:10.3390/cells10071794 · Cited by 184
Bioreactors for Cardiovascular Cell and Tissue Growth: A Review
Barron, V., Lyons, E., Stenson-Cox, C., McHugh, P. E., & Pandit, A. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1603260 · Cited by 182
The Evolution of Vascular Tissue Engineering and Current State of the Art
Peck, M., Gebhart, D., Dusserre, N., McAllister, T. N., & L’Heureux, N. (2012) · Cells Tissues Organs · doi:10.1159/000331406 · Cited by 181
Tissue Engineering Therapy for Cardiovascular Disease
Nugent, H. M., & Edelman, E. R. (2003) · Circulation Research · doi:10.1161/01.res.0000073844.41372.38 · Cited by 172
Vascular tissue engineering: from in vitro to in situ
Li, S., Sengupta, D., & Chien, S. (2014) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1246 · Cited by 164
Tissue-Engineered Blood Vessels: Alternative to Autologous Grafts?
Hoenig, M. R., Campbell, G. R., Rolfe, B. E., & Campbell, J. H. (2005) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000158996.03867.72 · Cited by 161
Self-citationHuman vascular microphysiological system for in vitro drug screening
Fernandez, C. E., Yen, R. W., Perez, S. M., Bedell, H. W., Povsic, T. J., Reichert, W. M., & Truskey, G. A. (2016) · Scientific Reports · doi:10.1038/srep21579 · Cited by 93
Polymeric Materials for Tissue Engineering of Arterial Substitutes
Ravi, S., Qu, Z., & Chaikof, E. L. (2009) · Vascular · doi:10.2310/6670.2008.00084 · Cited by 91
“After 2 to 3 weeks, the tubing was removed, and the mesothelium-lined, myofibroblast-rich construct was grafted into the carotid artery (rabbit), abdominal aorta (rat), or femoral artery (dog) of the animal in which it was grown.(156,157) Remodeling of the autologous grafts included differentiation of myofibroblasts t…”
MethodCellular Plasticity of Inflammatory Myeloid Cells in the Peritoneal Foreign Body Response
Mooney, J. E., Rolfe, B. E., Osborne, G. W., Sester, D. P., van Rooijen, N., Campbell, G. R., Hume, D. A., & Campbell, J. H. (2010) · The American Journal of Pathology · doi:10.2353/ajpath.2010.090545 · Cited by 87
Self-citationDevelopment and evaluation of in vivo tissue engineered blood vessels in a porcine model
Rothuizen, T. C., Damanik, F. F. R., Lavrijsen, T., Visser, M. J. T., Hamming, J. F., Lalai, R. A., Duijs, J. M. G. J., van Zonneveld, A. J., Hoefer, I. E., van Blitterswijk, C. A., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.10.023 · Cited by 84
“Importantly, not all rods implanted in the peritoneal cavity were encapsulated by a tissue capsule [55,56], making it necessary to implant multiple rods.”
Background
Metadata
- Authors
- Campbell, J. H., Efendy, J. L., & Campbell, G. R.
- Venue
- Circulation Research
- Published
- 1999-12-03
- Volume
- 85
- Issue
- 12
- Pages
- 1173-1178
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2103409893
- Cited by
- 293
- References
- 6
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.