The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
CT and Diffusion-Weighted MR Imaging in Randomized Order: Diffusion-Weighted Imaging Results in Higher Accuracy and Lower Interrater Variability in the Diagnosis of Hyperacute Ischemic Stroke
Open accessAbstract
Background and Purpose— Diffusion-weighted MRI (DWI) has become a commonly used imaging modality in stroke centers. The value of this method as a routine procedure is still being discussed. In previous studies, CT was always performed before DWI. Therefore, infarct progression could be a reason for the better result in DWI. Methods— All hyperacute (<6 hours) stroke patients admitted to our emergency department with a National Institutes of Health Stroke Scale (NIHSS) score >3 were prospectively randomized for the order in which CT and MRI were performed. Five stroke experts and 4 residents blinded to clinical data judged stroke signs and lesion size on the images. To determine the interrater variability, we calculated κ values for both rating groups. Results— A total of 50 patients with ischemic stroke and 4 patients with transient symptoms of acute stroke (median NIHSS score, 11; range, 3 to 27) were analyzed. Of the 50 patients, 55% were examined with DWI first. The mean delay from symptom onset until CT was 180 minutes; that from symptom onset until DWI was 189 minutes. The mean delay between DWI and CT was 30 minutes. The sensitivity of infarct detection by the experts was significantly better when based on DWI (CT/DWI, 61/91%). Accuracy was 91% when based on DWI (CT, 61%). Interrater variability of lesion detection was also significantly better for DWI (CT/DWI, κ=0.51/0.84). The assessment of lesion extent was less homogeneous on CT (CT/DWI, κ=0.38/0.62). The differences between the 2 modalities were stronger in the residents’ ratings (CT/DWI: sensitivity, 46/81%; κ=0.38/0.76). Conclusions— CT and DWI performed with the same delay after onset of ischemic stroke resulted in significant differences in diagnostic accuracy. DWI gives good interrater homogeneity and has a substantially better sensitivity and accuracy than CT even if the raters have limited experience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Measuring nominal scale agreement among many raters.
Fleiss, J. L. (1971) · Psychological Bulletin · doi:10.1037/h0031619 · Cited by 8,733
Hacke, W., Kaste, M., Fieschi, C., von Kummer, R., Davalos, A., Meier, D., Larrue, V., Bluhmki, E., Davis, S., Donnan, G., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(98)08020-9 · Cited by 3,662
Self-citationBarber, P. A., Demchuk, A. M., Zhang, J., & Buchan, A. M. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02237-6 · Cited by 2,668
Hacke, W. (1995) · JAMA · doi:10.1001/jama.1995.03530130023023 · Cited by 2,403
Self-citationPexman, J. H. W., Barber, P. A., Hill, M. D., Sevick, R. J., Demchuk, A. M., Hudon, M. E., Hu, W. Y., & Buchan, A. M. (2001) · PubMed · Cited by 1,092
Kidwell, C. S., Saver, J. L., Mattiello, J., Starkman, S., Vinuela, F., Duckwiler, G., Gobin, Y. P., Jahan, R., Vespa, P., Kalafut, M., et al. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200004)47:4<462::aid-ana9>3.0.co;2-y · Cited by 692
González, R. G., Schaefer, P. W., Buonanno, F. S., Schwamm, L. H., Budzik, R. F., Rordorf, G., Wang, B., Sorensen, A. G., & Koroshetz, W. J. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja02155 · Cited by 599
Diffusion MRI in Patients With Transient Ischemic Attacks
Kidwell, C. S., Alger, J. R., Di Salle, F., Starkman, S., Villablanca, P., Bentson, J., & Saver, J. L. (1999) · Stroke · doi:10.1161/01.str.30.6.1174 · Cited by 590
Prediction of stroke outcome with echoplanar perfusion- and diffusion-weighted MRI
Barber, P. A., Darby, D. G., Desmond, P. M., Yang, Q., Gerraty, R. P., Jolley, D., Donnan, G. A., Tress, B. M., & Davis, S. M. (1998) · Neurology · doi:10.1212/wnl.51.2.418 · Cited by 559
Hemorrhagic Transformation of Ischemic Brain Tissue: Asymptomatic or Symptomatic?
Berger, C., Fiorelli, M., Steiner, T., Schäbitz, W.-R., Bozzao, L., Bluhmki, E., Hacke, W., & von Kummer, R. (2001) · Stroke · doi:10.1161/01.str.32.6.1330 · Cited by 552
Self-citationMagnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Tong, D. C., Yenari, M. A., Albers, G. W., O'Brien, M., Marks, M. P., & Moseley, M. E. (1998) · Neurology · doi:10.1212/wnl.50.4.864 · Cited by 444
Early Prediction of Irreversible Brain Damage after Ischemic Stroke at CT
von Kummer, R., Bourquain, H., Bastianello, S., Bozzao, L., Manelfe, C., Meier, D., & Hacke, W. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap0695 · Cited by 343
Self-citationComparison of diffusion-weighted MRI and CT in acute stroke
Lansberg, M. G., Albers, G. W., Beaulieu, C., & Marks, M. P. (2000) · Neurology · doi:10.1212/wnl.54.8.1557 · Cited by 299
Early recanalisation in acute ischaemic stroke saves tissue at risk defined by MRI
Jansen, O., Schellinger, P., Fiebach, J., Hacke, W., & Sartor, K. (1999) · The Lancet · doi:10.1016/s0140-6736(99)01146-0 · Cited by 258
Self-citationStroke magnetic resonance imaging within 6 hours after onset of hyperacute cerebral ischemia
Schellinger, P. D., Fiebach, J. B., Jansen, O., Ringleb, P. A., Mohr, A., Steiner, T., Heiland, S., Schwab, S., Pohlers, O., Ryssel, H., et al. (2001) · Annals of Neurology · doi:10.1002/ana.95 · Cited by 226
Self-citationSchellinger, P. D., Jansen, O., Fiebach, J. B., Heiland, S., Steiner, T., Schwab, S., Pohlers, O., Ryssel, H., Sartor, K., & Hacke, W. (2000) · Stroke · doi:10.1161/01.str.31.6.1318 · Cited by 188
Self-citationSchellinger, P. D., Jansen, O., Fiebach, J. B., Pohlers, O., Ryssel, H., Heiland, S., Steiner, T., Hacke, W., & Sartor, K. J. (2000) · PubMed · Cited by 154
Self-citationTomsick, T. A., Brott, T. G., Chambers, A. A., Fox, A. J., Gaskill, M. F., Lukin, R. R., Pleatman, C. W., Wiot, J. G., & Bourekas, E. C. (1990) · PubMed Central · Cited by 115
Röther, J., de Crespigny, A. J., D'Arceuil, H. E., Iwai, K., & Moseley, M. E. (1996) · Stroke · doi:10.1161/01.str.27.5.980 · Cited by 89
Thrombolytic therapy for ischemic stroke—A review. Part I—Intravenous thrombolysis
Schellinger, P. D., Fiebach, J. B., Mohr, A., Ringleb, P. A., Jansen, O., & Hacke, W. (2001) · Critical Care Medicine · doi:10.1097/00003246-200109000-00027 · Cited by 80
Self-citationFiehler, J., Knab, R., Reichenbach, J. R., Fitzek, C., Weiller, C., & Röther, J. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200105000-00012 · Cited by 64
Interobserver Reliability in the Interpretation of Computed Tomographic Scans of Stroke Patients
Shinar, D., Gross, C. R., Hier, D. B., Caplan, L. R., Mohr, J. P., Price, T. R., Wolf, P. A., Kase, C. S., Fishman, I. G., Barwick, J. A., et al. (1987) · Archives of Neurology · doi:10.1001/archneur.1987.00520140021012 · Cited by 49
Powers, W. J. (2000) · Neurology · doi:10.1212/wnl.54.8.1549 · Cited by 43
Poststroke depression and emotional incontinence
Spalletta, G., Angelis, D. D., & Caltagirone, C. (2000) · Neurology · doi:10.1212/wnl.55.11.1760-a · Cited by 17
Cited by
Jauch, E. C., Saver, J. L., Adams, H. P., Bruno, A., Connors, J. J. (., Demaerschalk, B. M., Khatri, P., McMullan, P. W., Qureshi, A. I., Rosenfield, K., et al. (2013) · Stroke · doi:10.1161/str.0b013e318284056a · Cited by 7,634
Adams, H. P., del Zoppo, G., Alberts, M. J., Bhatt, D. L., Brass, L., Furlan, A., Grubb, R. L., Higashida, R. T., Jauch, E. C., Kidwell, C., et al. (2007) · Stroke · doi:10.1161/strokeaha.107.181486 · Cited by 2,475
Donnan, G. A., Fisher, M., Macleod, M., & Davis, S. M. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60694-7 · Cited by 2,218
Chalela, J. A., Kidwell, C. S., Nentwich, L. M., Luby, M., Butman, J. A., Demchuk, A. M., Hill, M. D., Patronas, N., Latour, L., & Warach, S. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60151-2 · Cited by 1,301
Adams, H. P., del Zoppo, G., Alberts, M. J., Bhatt, D. L., Brass, L., Furlan, A., Grubb, R. L., Higashida, R. T., Jauch, E. C., Kidwell, C., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181486 · Cited by 904
Metadata
- Authors
- Fiebach, J. B., Schellinger, P. D., Jansen, O., Meyer, M., Wilde, P., Bender, J., Schramm, P., Jüttler, E., Oehler, J., Hartmann, M., Hähnel, S., Knauth, M., Hacke, W., & Sartor, K.
- Venue
- Stroke
- Published
- 2002-09
- Volume
- 33
- Issue
- 9
- Pages
- 2206-2210
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2018151989
- Cited by
- 507
- References
- 27
- FWCI
- 15.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.