Comparison of Perfusion Computed Tomography and Computed Tomography Angiography Source Images With Perfusion-Weighted Imaging and Diffusion-Weighted Imaging in Patients With Acute Stroke of Less Than 6 Hours’ Duration

Open access
Schramm, Peter, Schellinger, Peter D., Klotz, Ernst, Kallenberg, Kai, Fiebach, Jochen B., Külkens, Sonja, Heiland, Sabine, Knauth, Michael, Sartor, Klaus·2004·Stroke

Abstract

Background and Purpose— We aimed to determine the diagnostic value of perfusion computed tomography (PCT) and CT angiography (CTA) including CTA source images (CTA-SI) in comparison with perfusion-weighted magnetic resonance imaging (MRI) (PWI) and diffusion-weighted MRI (DWI) in acute stroke <6 hours. Methods— Noncontrast-enhanced CT, PCT, CTA, stroke MRI, including PWI and DWI, and MR angiography (MRA), were performed in patients with symptoms of acute stroke lasting <6 hours. We analyzed ischemic lesion volumes on patients’ arrival as shown on NECT, PCT, CTA-SI, DWI, and PWI (Wilcoxon, Spearman, Bland-Altman) and compared them to the infarct extent as shown on day 5 NECT. Results— Twenty-two stroke patients underwent CT and MRI scanning within 6 hours. PCT time to peak (PCT-TTP) volumes did not differ from PWI-TTP ( P =0.686 for patients who did not undergo thrombolysis/ P =0.328 for patients who underwent thrombolysis), nor did PCT cerebral blood volume (PCT-CBV) differ from PWI-CBV ( P =0.893/ P =0.169). CTA-SI volumes did not differ from DWI volumes ( P =0.465/ P =0.086). Lesion volumes measured in PCT maps significantly correlated with lesion volumes on PWI ( P =0.0047, r =1.0/ P =0.0019, r =0.897 for TTP; P =0.0054, r =0.983/ P =0.0026, r =0.871 for CBV). Also, PCT-CBV lesion volumes significantly correlated with follow-up CT lesion volumes ( P =0.0047, r =1.0/ P =0.0046, r =0.819). Conclusions— In hyperacute stroke, the combination of PCT and CTA can render important diagnostic information regarding the infarct extent and the perfusion deficit. Lesions on PCT-TTP and PCT-CBV do not differ from lesions on PWI-TTP and PWI-CBV; lesions on CTA source images do not differ from lesions on DWI. The combination of noncontrast-enhanced CT (NECT), perfusion CT (PCT), and CT angiography (CTA) can render additional information within <15 minutes and may help in therapeutic decision-making if PWI and DWI are not available or cannot be performed on specific patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000131271.54098.22

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 312

Metadata

Authors
Schramm, P., Schellinger, P. D., Klotz, E., Kallenberg, K., Fiebach, J. B., Külkens, S., Heiland, S., Knauth, M., & Sartor, K.
Venue
Stroke
Published
2004-07
Volume
35
Issue
7
Pages
1652-1658
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2014427287
Cited by
312
References
21
FWCI
14.63
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Perfusion Computed Tomography and Computed Tomography Angiography Source Images With Perfusion-Weighted Imaging and Diffusion-Weighted Imaging in Patients With Acute Stroke of Less Than 6 Hours’ Duration. https://app.cochat.ai/papers/10.1161/01.str.0000131271.54098.22
The paper
Schramm, P., Schellinger, P. D., Klotz, E., Kallenberg, K., Fiebach, J. B., Külkens, S., Heiland, S., Knauth, M., & Sartor, K. (2004). Comparison of Perfusion Computed Tomography and Computed Tomography Angiography Source Images With Perfusion-Weighted Imaging and Diffusion-Weighted Imaging in Patients With Acute Stroke of Less Than 6 Hours’ Duration. Stroke. https://doi.org/10.1161/01.str.0000131271.54098.22

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.