The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Comparison of Admission Perfusion Computed Tomography and Qualitative Diffusion- and Perfusion-Weighted Magnetic Resonance Imaging in Acute Stroke Patients
Open accessAbstract
Background and Purpose — Besides classic criteria, cerebral perfusion imaging could improve patient selection for thrombolytic therapy. The purpose of this study was to compare quantitative perfusion CT imaging and qualitative diffusion- and perfusion-weighted MRI (DWI and PWI) in acute stroke patients at the time of their emergency evaluation. Methods — Thirteen acute stroke patients underwent perfusion CT and DWI or PWI on admission. The size of infarct and ischemic lesion (infarct plus penumbra) on the admission perfusion CT was compared with that of the MR abnormalities as shown on the DWI trace and on the relative cerebral blood volume, cerebral blood flow, time to peak, and mean transit time maps calculated from PWI studies. Results — The most significant correlation was found between infarct size on the admission perfusion CT and abnormality size on the admission DWI map ( r =0.968, P <0.001). A significant correlation was also observed between the size of the ischemic lesion (infarct plus penumbra) on the admission perfusion CT and the abnormality size on the mean transit time map calculated from admission PWI ( r =0.946, P <0.001). Information about cerebral infarct and total ischemia (infarct plus penumbra) carried by both imaging techniques was similar, with slopes of 0.913 and 0.905, respectively. Conclusions — An imaging technique may be helpful in the identification of cerebral penumbra in acute stroke patients and thus in the selection of patients for thrombolytic therapy. Perfusion CT and DWI/PWI are equivalent in this task.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hacke, W., Kaste, M., Fieschi, C., von Kummer, R., Davalos, A., Meier, D., Larrue, V., Bluhmki, E., Davis, S., Donnan, G., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(98)08020-9 · Cited by 3,662
Thresholds in cerebral ischemia - the ischemic penumbra.
Astrup, J., Siesjö, B. K., & Symon, L. (1981) · Stroke · doi:10.1161/01.str.12.6.723 · Cited by 2,820
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Viability thresholds and the penumbra of focal ischemia
Hossmann, K. (1994) · Annals of Neurology · doi:10.1002/ana.410360404 · Cited by 1,370
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging
Warach, S., Gaa, J., Siewert, B., Wielopolski, P., & Edelman, R. R. (1995) · Annals of Neurology · doi:10.1002/ana.410370214 · Cited by 1,004
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Sorensen, A. G., Buonanno, F. S., Gonzalez, R. G., Schwamm, L. H., Lev, M. H., Huang-Hellinger, F. R., Reese, T. G., Weisskoff, R. M., Davis, T. L., Suwanwela, N., et al. (1996) · Radiology · doi:10.1148/radiology.199.2.8668784 · Cited by 730
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715
Cited by
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Self-citationReal‐time diffusion‐perfusion mismatch analysis in acute stroke
Straka, M., Albers, G. W., & Bammer, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22338 · Cited by 401
Schramm, P., Schellinger, P. D., Klotz, E., Kallenberg, K., Fiebach, J. B., Külkens, S., Heiland, S., Knauth, M., & Sartor, K. (2004) · Stroke · doi:10.1161/01.str.0000131271.54098.22 · Cited by 312
Murphy, B. D., Fox, A. J., Lee, D. H., Sahlas, D. J., Black, S. E., Hogan, M. J., Coutts, S. B., Demchuk, A. M., Goyal, M., Aviv, R. I., et al. (2006) · Stroke · doi:10.1161/01.str.0000227243.96808.53 · Cited by 294
Markus, H. S. (2004) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2003.025825 · Cited by 293
Metadata
- Authors
- Wintermark, M., Reichhart, M., Cuisenaire, O., Maeder, P., Thiran, J.-P., Schnyder, P., Bogousslavsky, J., & Meuli, R.
- Venue
- Stroke
- Published
- 2002-08
- Volume
- 33
- Issue
- 8
- Pages
- 2025-2031
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2119201710
- Cited by
- 345
- References
- 38
- FWCI
- 16.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Admission Perfusion Computed Tomography and Qualitative Diffusion- and Perfusion-Weighted Magnetic Resonance Imaging in Acute Stroke Patients. https://app.cochat.ai/papers/10.1161/01.str.0000023579.61630.ac
- The paper
- Wintermark, M., Reichhart, M., Cuisenaire, O., Maeder, P., Thiran, J.-P., Schnyder, P., Bogousslavsky, J., & Meuli, R. (2002). Comparison of Admission Perfusion Computed Tomography and Qualitative Diffusion- and Perfusion-Weighted Magnetic Resonance Imaging in Acute Stroke Patients. Stroke. https://doi.org/10.1161/01.str.0000023579.61630.ac
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.