Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 414

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Transcranial Low-Frequency Ultrasound-Mediated Thrombolysis in Brain Ischemia: Increased Risk of Hemorrhage With Combined Ultrasound and Tissue Plasminogen Activator: Results of a Phase II Clinical Trial

Daffertshofer, Michael, Gass, Achim, Ringleb, Peter, Sitzer, Matthias, Sliwka, Ulrich, Els, Thomas, Sedlaczek, Oliver, Koroshetz, Walter J., Hennerici, Michael G.·2005·Stroke

Abstract

Background— Clinical studies using ultrasound at diagnostic frequencies in transcranial Doppler devices provided encouraging results in enhancing thrombolysis with tissue plasminogen activator (tPA) in acute stroke. Low-frequency ultrasound does not require complex positioning procedures, penetrates through the skull better, and has been demonstrated to accelerate thrombolysis with tPA in animal experiments in wide cerebrovascular territories without hemorrhagic side effects. We therefore conducted the first multicenter clinical trial to investigate safety of tPA plus low-frequency ultrasound (300 kHz). Methods— Acute stroke patients within a 6-hour time window were included (National Institutes of Health Stroke Scale scores >4). Magnetic resonance imaging (MRI) was used to document vascular occlusion and to rule out cerebral hemorrhage. Patients were allocated to combination therapy alternately; the first patient received tPA only, the second patient received tPA plus ultrasound, etc. Follow-up included serial MRI directly thereafter and 24 hours later to confirm recanalization and tissue imaging. Clinical recovery was measured after treatment and 3 months later. Results— 26 patients (70.4±9.7 years) entered the trial (12 tPA, 14 tPA plus ultrasound). The study was prematurely stopped because 5 of 12 patients from the tPA only group but 13 of 14 patients treated with the tPA plus ultrasound showed signs of bleeding in MRI ( P <0.01). Within 3 days of treatment, 5 symptomatic hemorrhages occurred within the tPA plus ultrasound group. At 3 months, neither morbidity nor treatment-related mortality or recanalization rates differed between both groups. Conclusions— This study demonstrated bioeffects from low-frequency ultrasound that caused an increased rate of cerebral hemorrhages in patients concomitantly treated with intravenous tPA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000170707.86793.1a

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 414

Metadata

Authors
Daffertshofer, M., Gass, A., Ringleb, P., Sitzer, M., Sliwka, U., Els, T., Sedlaczek, O., Koroshetz, W. J., & Hennerici, M. G.
Venue
Stroke
Published
2005-07
Volume
36
Issue
7
Pages
1441-1446
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2123412262
Cited by
414
References
15
FWCI
19.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcranial Low-Frequency Ultrasound-Mediated Thrombolysis in Brain Ischemia: Increased Risk of Hemorrhage With Combined Ultrasound and Tissue Plasminogen Activator: Results of a Phase II Clinical Trial. https://app.cochat.ai/papers/10.1161/01.str.0000170707.86793.1a
The paper
Daffertshofer, M., Gass, A., Ringleb, P., Sitzer, M., Sliwka, U., Els, T., Sedlaczek, O., Koroshetz, W. J., & Hennerici, M. G. (2005). Transcranial Low-Frequency Ultrasound-Mediated Thrombolysis in Brain Ischemia: Increased Risk of Hemorrhage With Combined Ultrasound and Tissue Plasminogen Activator: Results of a Phase II Clinical Trial. Stroke. https://doi.org/10.1161/01.str.0000170707.86793.1a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.