Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

The four-vessel occlusion rat model: method for complete occlusion of vertebral arteries and control of collateral circulation.

Open access
Pulsinelli, W A, Buchan, A M·1988·Stroke

Abstract

F our-vessel occlusion in rats was introduced approximately 10 years ago 1 to provide a rodent model of reversible forebrain ischemia.The model presented several advantages, which included ease of preparation, a high rate of predictable ischemic neuronal damage, a low incidence of seizures, and the absence of anesthesia.However, two issues concerning the efficient use of the four-vessel occlusion rat model as originally described by us'-3 require clarification.First, several groups 4 -7 have reported difficulty assuring complete occlusion of the vertebral arteries by electrocauterization through the alar foramina of the first cervical vertebra.Because this difficulty may stem partly from our failure to have adequately described details of this method in our original article, the following is provided to facilitate more effective use of the model.It is important to position the anesthetized rat's head in stereotactic ear bars with the head tilted down at approximately 30° to the horizontal.The cervical spine is gently stretched by placing tension on the rat's tail with a rubber band anchored to the table.These steps stabilize and rotate the first cervical vertebra such that the alar wings are horizontal to the table; the full perimeters of the alar foramina can therefore be seen.The alar foramina (see Figure 1 in Reference 1) are easily approached via a midline dorsal neck incision.A pivoting, dissection microscope with through-the-lens or direct lighting is essential to carry out the following procedure.Once the alar foramina are visualized with the microscope, a small (<1 mm) electrocautery needle is inserted vertically through the alar foramina and down into the bony tunnel of the first vertebra, through which the vertebral arteries travel.Brief, intermittent application of current to the needle tip will cauterize the vertebral arteries and avert bleeding in the majority of rats.In those rats

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.19.7.913

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 260

Metadata

Authors
Pulsinelli, W. A., & Buchan, A. M.
Venue
Stroke
Published
1988-07
Volume
19
Issue
7
Pages
913-914
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1986582031
Cited by
260
References
5
FWCI
3.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The four-vessel occlusion rat model: method for complete occlusion of vertebral arteries and control of collateral circulation. https://app.cochat.ai/papers/10.1161/01.str.19.7.913
The paper
Pulsinelli, W. A., & Buchan, A. M. (1988). The four-vessel occlusion rat model: method for complete occlusion of vertebral arteries and control of collateral circulation. Stroke. https://doi.org/10.1161/01.str.19.7.913

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.