Matrix Metalloproteinase Expression After Human Cardioembolic Stroke: Temporal Profile and Relation to Neurological Impairment

Montaner, Joan, Alvarez-Sabín, José, Molina, Carlos, Anglés, Ana, Abilleira, Sonia, Arenillas, Juan, González, Miguel Angel, Monasterio, Jasone·2001·Stroke

Abstract

Background and Purpose — Uncontrolled expression of matrix metalloproteinases (MMPs) can result in tissue injury and inflammation. In animal models of cerebral ischemia, the expression of MMP-2 and MMP-9 was significantly increased. However, their role in human stroke in vivo remains unknown. Therefore, we sought to determine the temporal profile of MMP expression in patients with acute ischemic stroke and to investigate its relationship to stroke severity, location of arterial occlusion, and total infarct volume. Methods — Serial MMP-2 and MMP-9 determinations were made in 39 patients with cardioembolic strokes that involved the middle cerebral artery territory by means of enzyme-linked immunosorbent assay. Blood samples, transcranial Doppler recordings, and National Institutes of Health Stroke Scale (NIHSS) scores were obtained at baseline and at 12, 24, and 48 hours after stroke onset. Infarct volume was measured with CT scanning at 48 hours. Results — No correlation was found between MMP-2 and NIHSS score at any time point, although a close relation appeared between mean MMP-9 and final NIHSS score ( r =0.486, P =0.002). MMP-9 value was the only factor associated with the final NIHSS score in the multiple logistic regression model (OR 4.54, 95% CI 1.5 to 13.75). A cut-point of MMP-9 142.18 ng/mL had a positive predictive value of 94.4% to assess a patient’s NIHSS (<8 or ≥8) by the end of the study. Final MMP-2 and MMP-9 levels were significantly lower when recanalization occurred (528±144.3 versus 681.4±239.2 ng/mL, P =0.031 for MMP-2; 110.2±100.9 versus 244.8±130 ng/mL, P =0.004 for MMP-9). A positive correlation was found between mean MMP-9 and infarct volume ( r =0.385, P =0.022). Conclusions — MMPs are involved in the acute phase of human ischemic stroke. MMP-9 levels are associated with neurological deficit, middle cerebral artery occlusion, and infarct volume.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.32.8.1759

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 350

Metadata

Authors
Montaner, J., Alvarez-Sabín, J., Molina, C., Anglés, A., Abilleira, S., Arenillas, J., González, M. A., & Monasterio, J.
Venue
Stroke
Published
2001-08
Volume
32
Issue
8
Pages
1759-1766
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2096976767
Cited by
350
References
28
FWCI
8.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Matrix Metalloproteinase Expression After Human Cardioembolic Stroke: Temporal Profile and Relation to Neurological Impairment. https://app.cochat.ai/papers/10.1161/01.str.32.8.1759
The paper
Montaner, J., Alvarez-Sabín, J., Molina, C., Anglés, A., Abilleira, S., Arenillas, J., González, M. A., & Monasterio, J. (2001). Matrix Metalloproteinase Expression After Human Cardioembolic Stroke: Temporal Profile and Relation to Neurological Impairment. Stroke. https://doi.org/10.1161/01.str.32.8.1759

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.