Pulmonary Vein Isolation for the Maintenance of Sinus Rhythm in Patients With Atrial Fibrillation: A Meta-Analysis of Randomized, Controlled Trials
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Background— Catheter ablation is an established yet evolving nonpharmacologic intervention for the maintenance of sinus rhythm in patients with atrial fibrillation (AF). The efficacy and safety of pulmonary vein isolation (PVI) compared with medical therapy remain in question. Methods and Results— We conducted a meta-analysis of all randomized, controlled trials comparing PVI and medical therapy for the maintenance of sinus rhythm. The primary end point in this analysis was freedom from recurrent AF at 12 months. The relative efficacy of PVI was estimated using random-effects modeling according to intention to treat. We identified 6 trials that randomized a total of 693 patients with AF to PVI or control. PVI was associated with markedly increased odds of freedom from AF at 12 months of follow-up (n=266/344 [77%] versus n=102/346 [29%]; odds ratio, 9.74; 95% CI, 3.98 to 23.87). When we excluded the trial that only enrolled patients with persistent AF (Q-statistic, 2.485; P =0.647 after exclusion), PVI was associated with even greater odds of AF-free survival (15.78; 95% CI, 10.07 to 24.73). PVI was associated with a decreased hospitalization for cardiovascular causes (14 versus 93 per 100 person-years; rate ratio, 0.15; 95% CI, 0.10 to 0.23). Among those randomly assigned to PVI, 17% required a repeat PVI ablation before 12 months. The rate of major complications was 2.6% (n=9/344) in the catheter ablation group. Conclusions— Compared with a nonablation treatment strategy, PVI results in dramatically increased freedom from AF at 1 year. Although the procedure can be associated with major complications, the risk of these complications is comparable to other interventional procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Packer, D., & Skanes, A. (2005) · Circulation · doi:10.1161/01.cir.0000157153.30978.67 · Cited by 1,305
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.009 · Cited by 1,158
Cited by
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Guidelines for the management of atrial fibrillation
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · EP Europace · doi:10.1093/europace/euq350 · Cited by 1,747
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Wann, L. S., Curtis, A. B., January, C. T., Ellenbogen, K. A., Lowe, J. E., Estes, N. A. M., Page, R. L., Ezekowitz, M. D., Slotwiner, D. J., Jackman, W. M., et al. (2011) · Circulation · doi:10.1161/cir.0b013e3181fa3cf4 · Cited by 1,336
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Ganesan, A. N., Shipp, N. J., Brooks, A. G., Kuklik, P., Lau, D. H., Lim, H. S., Sullivan, T., Roberts‐Thomson, K. C., & Sanders, P. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.004549 · Cited by 800
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.021 · Cited by 576
Verma, A., Cairns, J. A., Mitchell, L. B., Macle, L., Stiell, I. G., Gladstone, D., McMurtry, M. S., Connolly, S., Cox, J. L., Dorian, P., et al. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.08.001 · Cited by 477
Wann, L. S., Curtis, A. B., Ellenbogen, K. A., Estes, N. A. M., Ezekowitz, M. D., Jackman, W. M., January, C. T., Lowe, J. E., Page, R. L., Slotwiner, D. J., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.01.032 · Cited by 395
Lip, G. Y., Tse, H. F., & Lane, D. A. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61514-6 · Cited by 338
Hakalahti, A., Biancari, F., Nielsen, J. C., & Raatikainen, M. J. P. (2015) · Europace · doi:10.1093/europace/euu376 · Cited by 191
Wynn, G. J., Das, M., Bonnett, L. J., Panikker, S., Wong, T., & Gupta, D. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001759 · Cited by 146
SCHMIDT, M., DORWARTH, U., ANDRESEN, D., BRACHMANN, J., KUCK, K., KUNISS, M., LEWALTER, T., SPITZER, S., WILLEMS, S., SENGES, J., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12267 · Cited by 126
Metadata
- Authors
- Piccini, J. P., Lopes, R. D., Kong, M. H., Hasselblad, V., Jackson, K., & Al-Khatib, S. M.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2009-12
- Volume
- 2
- Issue
- 6
- Pages
- 626-633
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2162622568
- Cited by
- 290
- References
- 31
- FWCI
- 15.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.