Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 412

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Endocardial Unipolar Voltage Mapping to Detect Epicardial Ventricular Tachycardia Substrate in Patients With Nonischemic Left Ventricular Cardiomyopathy

Open access
Hutchinson, Mathew D., Gerstenfeld, Edward P., Desjardins, Benoit, Bala, Rupa, Riley, Michael P., Garcia, Fermin C., Dixit, Sanjay, Lin, David, Tzou, Wendy S., Cooper, Joshua M., Verdino, Ralph J., Callans, David J., Marchlinski, Francis E. · 2011 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Patients with nonischemic left ventricular cardiomyopathy (LVCM) and ventricular tachycardia (V t ) have complex 3-dimensional substrate with variable involvement of the endocardium (ENDO) and epicardium (EPI). The purpose of this study was to determine whether ENDO unipolar (UNI) mapping with a larger electric field of view could identify EPI low bipolar (BIP) voltage regions in patients with LVCM undergoing V t ablation. Methods and Results—: The reference value for normal ENDO unipolar voltage was determined from 6 patients without structural heart disease. Consecutive patients undergoing V t ablation over an 8-year period with detailed (>100 points) LV ENDO and EPI mapping and normal LV ENDO BIP voltage were identified. From this cohort, we compared patients with structurally normal hearts and normal EPI BIP voltage (EPI−, group 1) with patients with LVCM and low LV EPI BIP voltage regions present (EPI+, group 2). Confluent regions of ENDO UNI and EPI BIP low voltage (>2 cm 2 ) were measured. The normal signal amplitude was >8.27 mV for LV ENDO UNI electrograms. Detailed LV ENDO-EPI maps in 5 EPI− patients were compared with 11 EPI+ patients. Confluent ENDO UNI low-voltage regions were seen in 9 of 11 (82%) of the EPI+ (group 2) patients compared with none of 5 EPI− (group 1) patients ( P <0.001). In all 9 patients with ENDO UNI low voltage, the ENDO UNI low-voltage regions were directly opposite to an area of EPI BIP low voltage (61% ENDO UNI-EPI BIP low-voltage area overlap). Conclusions—: EPI arrhythmia substrate can be reliably identified in most patients with LVCM using ENDO UNI voltage mapping in the absence of ENDO BIP abnormalities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.110.959957

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 412

Metadata

Authors
Hutchinson, M. D., Gerstenfeld, E. P., Desjardins, B., Bala, R., Riley, M. P., Garcia, F. C., Dixit, S., Lin, D., Tzou, W. S., Cooper, J. M., Verdino, R. J., Callans, D. J., & Marchlinski, F. E.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2011-02
Volume
4
Issue
1
Pages
49-55
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2121838979
Cited by
412
References
9
FWCI
11.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Endocardial Unipolar Voltage Mapping to Detect Epicardial Ventricular Tachycardia Substrate in Patients With Nonischemic Left Ventricular Cardiomyopathy. https://app.cochat.ai/papers/10.1161/circep.110.959957
The paper
Hutchinson, M. D., Gerstenfeld, E. P., Desjardins, B., Bala, R., Riley, M. P., Garcia, F. C., Dixit, S., Lin, D., Tzou, W. S., Cooper, J. M., Verdino, R. J., Callans, D. J., & Marchlinski, F. E. (2011). Endocardial Unipolar Voltage Mapping to Detect Epicardial Ventricular Tachycardia Substrate in Patients With Nonischemic Left Ventricular Cardiomyopathy. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.110.959957

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.