The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment: Results From the EFFICAS I Study
Abstract
Background—: Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up. Method and Results—: A radiofrequency ablation catheter with integrated CF sensor (TactiCath, Endosense, Geneva, Switzerland) was used to perform pulmonary vein isolation in 46 patients with paroxysmal atrial fibrillation. During the ablation procedure, the operator was blinded to CF information. At follow-up, an interventional diagnostic procedure was performed to assess gap location as correlated to index procedure ablation parameters. At follow-up, 65% (26/40) of patients showed ≥1 gaps. Ablations with minimum Force–Time Integral (FTI) <400 gs showed increased likelihood for reconnection ( P <0.001). Reconnection correlated strongly with minimum CF ( P <0.0001) and minimum FTI ( P =0.0007) at the site of gap. Gap occurrence showed a strong trend with lower average CF and average FTI. CF and FTI are generally higher on the right side, although the left anterior segment presents a unique challenge to achieve stable position with good CF. Conclusions—: Minimum CF and minimum FTI values are strong predictors of gap formation. Optimal CF parameter recommendations are a target CF of 20 g and a minimum FTI of 400 gs for each new lesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationWilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
Self-citationOuyang, F., Tilz, R., Chun, J., Schmidt, B., Wissner, E., Zerm, T., Neven, K., Köktürk, B., Konstantinidou, M., Metzner, A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.946806 · Cited by 706
Self-citationYokoyama, K., Nakagawa, H., Shah, D. C., Lambert, H., Leo, G., Aeby, N., Ikeda, A., Pitha, J. V., Sharma, T., Lazzara, R., et al. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.803650 · Cited by 624
Self-citationReddy, V. Y., Shah, D., Kautzner, J., Schmidt, B., Saoudi, N., Herrera, C., Jaïs, P., Hindricks, G., Peichl, P., Yulzari, A., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.016 · Cited by 484
Self-citationVenice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Self-citationA novel radiofrequency ablation catheter using contact force sensing: Toccata study
Kuck, K.-H., Reddy, V. Y., Schmidt, B., Natale, A., Neuzil, P., Saoudi, N., Kautzner, J., Herrera, C., Hindricks, G., Jaïs, P., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.08.021 · Cited by 311
Self-citationKISTLER, P. M., HO, S. Y., RAJAPPAN, K., MORPER, M., HARRIS, S., ABRAMS, D., SPORTON, S. C., & SCHILLING, R. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00981.x · Cited by 290
Natural History and Long-Term Outcomes of Ablated Atrial Fibrillation
Hussein, A. A., Saliba, W. I., Martin, D. O., Bhargava, M., Sherman, M., Magnelli-Reyes, C., Chamsi-Pasha, M., John, S., Williams-Adrews, M., Baranowski, B., et al. (2011) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.111.962100 · Cited by 165
Radiofrequency Ablation of Atrial Fibrillation
Pratola, C., BALDO, E., Notarstefano, P., Toselli, T., & Ferrari, R. (2007) · Circulation · doi:10.1161/circulationaha.106.678789 · Cited by 106
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Self-citationAndrade, J. G., Champagne, J., Dubuc, M., Deyell, M. W., Verma, A., Macle, L., Leong-Sit, P., Novak, P., Badra-Verdu, M., Sapp, J., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.042622 · Cited by 570
Pulsed Field Ablation of Paroxysmal Atrial Fibrillation
Reddy, V. Y., Dukkipati, S. R., Neuzil, P., Anic, A., Petru, J., Funasako, M., Cochet, H., Minami, K., Breskovic, T., Sikiric, I., et al. (2021) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.02.014 · Cited by 558
Self-citation
Metadata
- Authors
- Neuzil, P., Reddy, V. Y., Kautzner, J., Petru, J., Wichterle, D., Shah, D., Lambert, H., Yulzari, A., Wissner, E., & Kuck, K.-H.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2013-04
- Volume
- 6
- Issue
- 2
- Pages
- 327-333
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2625253140
- Cited by
- 434
- References
- 11
- FWCI
- 31.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment: Results From the EFFICAS I Study. https://app.cochat.ai/papers/10.1161/circep.113.000374
- The paper
- Neuzil, P., Reddy, V. Y., Kautzner, J., Petru, J., Wichterle, D., Shah, D., Lambert, H., Yulzari, A., Wissner, E., & Kuck, K.-H. (2013). Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment: Results From the EFFICAS I Study. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.113.000374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.