A Randomized Controlled Trial of Catheter Ablation Versus Medical Treatment of Atrial Fibrillation in Heart Failure (The CAMTAF Trial)

Hunter, Ross J., Berriman, Thomas J., Diab, Ihab, Kamdar, Ravindu, Richmond, Laura, Baker, Victoria, Goromonzi, Farai, Sawhney, Vinit, Duncan, Edward, Page, Stephen P., Ullah, Waqas, Unsworth, Beth, Mayet, Jamil, Dhinoja, Mehul, Earley, Mark J., Sporton, Simon, Schilling, Richard J.·2014·Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Restoring sinus rhythm in patients with heart failure (HF) and atrial fibrillation (AF) may improve left ventricular (LV) function and HF symptoms. We sought to compare the effect of a catheter ablation strategy with that of a medical rate control strategy in patients with persistent AF and HF. Methods and Results—: Patients with persistent AF, symptomatic HF, and LV ejection fraction <50% were randomized to catheter ablation or medical rate control. The primary end-point was the difference between groups in LV ejection fraction at 6 months. Baseline LV ejection fraction was 32±8% in the ablation group and 34±12% in the medical group. Twenty-six patients underwent catheter ablation, and 24 patients were rate controlled. Freedom from AF was achieved in 21/26 (81%) at 6 months off antiarrhythmic drugs. LV ejection fraction at 6 months in the ablation group was 40±12% compared with 31±13% in the rate control group ( P =0.015). Ablation was associated with better peak oxygen consumption (22±6 versus 18±6 mL/kg per minute; P =0.014) and Minnesota living with HF questionnaire score (24±22 versus 47±22; P =0.001) compared with rate control. Conclusions—: Catheter ablation is effective in restoring sinus rhythm in selected patients with persistent AF and HF, and can improve LV function, functional capacity, and HF symptoms compared with rate control. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01411371

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.113.000806

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 44 references

Cited by

See all 505

Metadata

Authors
Hunter, R. J., Berriman, T. J., Diab, I., Kamdar, R., Richmond, L., Baker, V., Goromonzi, F., Sawhney, V., Duncan, E., Page, S. P., Ullah, W., Unsworth, B., Mayet, J., Dhinoja, M., Earley, M. J., Sporton, S., & Schilling, R. J.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2014-02
Volume
7
Issue
1
Pages
31-38
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2115347173
Cited by
505
References
44
FWCI
20.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Randomized Controlled Trial of Catheter Ablation Versus Medical Treatment of Atrial Fibrillation in Heart Failure (The CAMTAF Trial). https://app.cochat.ai/papers/10.1161/circep.113.000806
The paper
Hunter, R. J., Berriman, T. J., Diab, I., Kamdar, R., Richmond, L., Baker, V., Goromonzi, F., Sawhney, V., Duncan, E., Page, S. P., Ullah, W., Unsworth, B., Mayet, J., Dhinoja, M., Earley, M. J., Sporton, S., & Schilling, R. J. (2014). A Randomized Controlled Trial of Catheter Ablation Versus Medical Treatment of Atrial Fibrillation in Heart Failure (The CAMTAF Trial). Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.113.000806

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.