Tailored Atrial Substrate Modification Based on Low-Voltage Areas in Catheter Ablation of Atrial Fibrillation

Rolf, Sascha, Kircher, Simon, Arya, Arash, Eitel, Charlotte, Sommer, Philipp, Richter, Sergio, Gaspar, Thomas, Bollmann, Andreas, Altmann, David, Piedra, Carlos, Hindricks, Gerhard, Piorkowski, Christopher·2014·Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Reduced electrogram amplitude has been shown to correlate with diseased myocardium. We describe a novel individualized approach for catheter ablation of atrial fibrillation (AF) based on low-voltage areas (LVAs) in the left atrium (LA). We sought to assess (1) the incidence of LVAs in patients undergoing AF catheter ablation, (2) the distribution of LVAs within the LA, and (3) the effect of an individualized ablation strategy on long-term rhythm outcomes. Methods and Results—: In 178 patients with paroxysmal or persistent AF, LA voltage maps were created during sinus rhythm after circumferential pulmonary vein isolation. Subsequent substrate modification was confined to the presence of LVA (<0.5 mV) and inducible regular atrial tachycardias. LVAs were identified in 35% and 10% of patients with persistent and paroxysmal AF, respectively. The LA roof and the anterior, septal, and posterior wall LA were most often affected. The 12-month atrial tachycardias/AF-free survival was 62% for patients without LVAs and 70% for patients with LVAs and tailored substrate modification ( P =0.3). Success rate in a comparison group of 26 LVA patients without further substrate modification was 27%. Conclusions—: LVAs can be found at preferred sites in 10% of patients with paroxysmal AF and in 35% of patients with persistent AF. This is the first clinical report describing a consistent voltage-based approach for substrate modification in addition to circumferential pulmonary vein isolation irrespective of AF type. Application of this limited individualized approach may have the potential to compensate for the impaired 12-month outcome of patients with endocardial structural defects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.113.001251

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 561

Metadata

Authors
Rolf, S., Kircher, S., Arya, A., Eitel, C., Sommer, P., Richter, S., Gaspar, T., Bollmann, A., Altmann, D., Piedra, C., Hindricks, G., & Piorkowski, C.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2014-10
Volume
7
Issue
5
Pages
825-833
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2136673459
Cited by
561
References
21
FWCI
25.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tailored Atrial Substrate Modification Based on Low-Voltage Areas in Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circep.113.001251
The paper
Rolf, S., Kircher, S., Arya, A., Eitel, C., Sommer, P., Richter, S., Gaspar, T., Bollmann, A., Altmann, D., Piedra, C., Hindricks, G., & Piorkowski, C. (2014). Tailored Atrial Substrate Modification Based on Low-Voltage Areas in Catheter Ablation of Atrial Fibrillation. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.113.001251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.