Quantitative Analysis of Localized Sources Identified by Focal Impulse and Rotor Modulation Mapping in Atrial Fibrillation
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Background—: New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM) mapping, and initial results reported with this technique have been favorable. We sought to independently evaluate the approach by analyzing quantitative characteristics of atrial electrograms used to identify rotors and describe acute procedural outcomes of FIRM-guided ablation. Methods and Results—: All FIRM-guided ablation procedures (n=24; 50% paroxysmal) at University of California, Los Angeles Medical Center were included for analysis. During AF, unipolar atrial electrograms collected from a 64-pole basket catheter were used to construct phase maps and identify putative AF sources. These sites were targeted for ablation, in conjunction with pulmonary vein isolation in most patients (n=19; 79%). All patients had rotors identified (mean, 2.3±0.9 per patient; 72% in left atrium). Prespecified acute procedural end point was achieved in 12 of 24 (50%) patients: AF termination (n=1), organization (n=3), or >10% slowing of AF cycle length (n=8). Basket electrodes were within 1 cm of 54% of left atrial surface area, and a mean of 31 electrodes per patient showed interpretable atrial electrograms. Offline analysis revealed no differences between rotor and distant sites in dominant frequency or Shannon entropy. Electroanatomic mapping showed no rotational activation at FIRM-identified rotor sites in 23 of 24 patients (96%). Conclusions—: FIRM-identified rotor sites did not exhibit quantitative atrial electrogram characteristics expected from rotors and did not differ quantitatively from surrounding tissue. Catheter ablation at these sites, in conjunction with pulmonary vein isolation, resulted in AF termination or organization in a minority of patients (4/24; 17%). Further validation of this approach is necessary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Treatment of Atrial Fibrillation by the Ablation of Localized Sources
Narayan, S. M., Krummen, D. E., Shivkumar, K., Clopton, P., Rappel, W.-J., & Miller, J. M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.022 · Cited by 1,117
Self-citationSpatial and temporal organization during cardiac fibrillation
Gray, R. A., Pertsov, A. M., & Jalife, J. (1998) · Nature · doi:10.1038/32164 · Cited by 958
Driver domains in persistent atrial fibrillation
Haissaguerre, M., Hocini, M., Denis, A., Shah, A. J., Komatsu, Y., Yamashita, S., Daly, M., Amraoui, S., Zellerhoff, S., Picat, M.-Q., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005421 · Cited by 734 · cited 1×
“More recently, physiologic mapping of AF has been utilized to identify areas of the atrium that may be responsible for maintaining AF, in an attempt to identify patient-specific drivers to design tailored ablation strategies.(6-9) One such method with promising results is focal impulse and rotor modulation (FIRM).”
Stable Microreentrant Sources as a Mechanism of Atrial Fibrillation in the Isolated Sheep Heart
Mandapati, R., Skanes, A., Chen, J., Berenfeld, O., & Jalife, J. (2000) · Circulation · doi:10.1161/01.cir.101.2.194 · Cited by 725 · cited 1×
“In animal models, rotors characterized by a series of stable high-frequency electrograms around the repetitive circular path have been described.(15) We did not see regular, monomorphic electric activity in any of the FIRM-identified rotor areas.”
Self-citationPiccini, J. P., Hammill, B. G., Sinner, M. F., Jensen, P. N., Hernandez, A. F., Heckbert, S. R., Benjamin, E. J., & Curtis, L. H. (2012) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.111.962688 · Cited by 565 · cited 1×
“3 Background Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in adults, and is associated with thromboembolic complications, myocardial and neuronal remodeling and increased mortality.(1) Surgical and percutaneous treatments involve ablative therapy targeted at isolating or eliminating putativ…”
Outcomes of long-standing persistent atrial fibrillation ablation: A systematic review
Brooks, A. G., Stiles, M. K., Laborderie, J., Lau, D. H., Kuklik, P., Shipp, N. J., Hsu, L.-F., & Sanders, P. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.01.017 · Cited by 487 · cited 1×
“Ablation results are particularly disappointing for longstanding persistent AF, in which complex substrate and patient-specific sustaining mechanisms have been reported.(3,4) This has led to a wide range of procedural approaches to persistent AF ablation, with most operators targeting atrial substrate in addition to p…”
Spatiotemporal Periodicity During Atrial Fibrillation in the Isolated Sheep Heart
Skanes, A. C., Mandapati, R., Berenfeld, O., Davidenko, J. M., & Jalife, J. (1998) · Circulation · doi:10.1161/01.cir.98.12.1236 · Cited by 479
Self-citationCatheter Ablation of Long-Standing Persistent Atrial Fibrillation
Tilz, R. R., Rillig, A., Thum, A.-M., Arya, A., Wohlmuth, P., Metzner, A., Mathew, S., Yoshiga, Y., Wissner, E., Kuck, K.-H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.04.060 · Cited by 469 · cited 1×
“Ablation results are particularly disappointing for longstanding persistent AF, in which complex substrate and patient-specific sustaining mechanisms have been reported.(3,4) This has led to a wide range of procedural approaches to persistent AF ablation, with most operators targeting atrial substrate in addition to p…”
de Groot, N. M. S., Houben, R. P. M., Smeets, J. L., Boersma, E., Schotten, U., Schalij, M. J., Crijns, H., & Allessie, M. A. (2010) · Circulation · doi:10.1161/circulationaha.109.910901 · Cited by 357
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Calkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux275 · Cited by 509
Buch, E., Share, M., Tung, R., Benharash, P., Sharma, P., Koneru, J., Mandapati, R., Ellenbogen, K. A., & Shivkumar, K. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.10.031 · Cited by 220
Self-citation
Metadata
- Authors
- Benharash, P., Buch, E., Frank, P., Share, M., Tung, R., Shivkumar, K., & Mandapati, R.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2015-06
- Volume
- 8
- Issue
- 3
- Pages
- 554-561
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2060299481
- Cited by
- 179
- References
- 22
- FWCI
- 27.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.