The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Uncovering Atrial Fibrillation Beyond Short-Term Monitoring in Cryptogenic Stroke Patients: Three-Year Results From the Cryptogenic Stroke and Underlying Atrial Fibrillation Trial
Abstract
Background—: Atrial fibrillation (AF) can be a cause of previously diagnosed cryptogenic stroke. However, AF can be paroxysmal and asymptomatic, thereby making detection with routine ECG methods difficult. Oral anticoagulation is highly effective in reducing recurrent stroke in patients with AF, but its initiation is dependent on the detection of AF. Cryptogenic Stroke and Underlying Atrial Fibrillation (CRYSTAL AF) is the first randomized study to report the detection of AF in cryptogenic stroke patients using continuous long-term monitoring via insertable cardiac monitors (ICM). Methods and Results—: Patients with prior cryptogenic stroke were randomized to control (n=220) or ICM (n=221) and followed for ≤36 months. Cumulative AF detection rates in the ICM arm increased progressively during this period (3.7%, 8.9%, 12.4%, and 30.0% at 1, 6, 12, and 36 months, respectively), but remained low in the control arm (3.0% at 36 months). This resulted in oral anticoagulation prescription in 94.7% of ICM patients with AF detected at 6 months, 96.6% at 12 months, and 90.5% at 36 months. Among ICM patients with AF detected, the median time to AF detection was 8.4 months, 81.0% of first AF episodes were asymptomatic, and 94.9% had at least 1 day with >6 minutes of AF. Conclusions—: Three-year monitoring by ICM in cryptogenic stroke patients demonstrated a significantly higher AF detection rate compared with routine care. Given the frequency of asymptomatic first episodes and the long median time to detection, these findings highlight the limitations of using traditional AF detection methods. The majority of patients with AF were prescribed oral anticoagulation therapy. Clinical Trial Registration—: Clinicaltrials.gov ; Unique identifier: NCT00924638.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kernan, W. N., Ovbiagele, B., Black, H. R., Bravata, D. M., Chimowitz, M. I., Ezekowitz, M. D., Fang, M. C., Fisher, M., Furie, K. L., Heck, D. V., et al. (2014) · Stroke · doi:10.1161/str.0000000000000024 · Cited by 5,170
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Self-citationSubclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Self-citationGlotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750 · cited 1×
“The Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial (ASSERT), performed in patients without stroke and carriers of a cardiac implantable electronic device, found that AF episodes lasting >6 minutes were associated with an increased…”
ResultTemporal relationship between subclinical atrial fibrillation and embolic events
Brambatti, M., Connolly, S. J., Gold, M. R., Morillo, C. A., Capucci, A., Muto, C., Lau, C. P., Van Gelder, I. C., Hohnloser, S. H., Carlson, M., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.007825 · Cited by 676
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Daoud, E. G., Glotzer, T. V., Wyse, D. G., Ezekowitz, M. D., Hilker, C., Koehler, J., & Ziegler, P. D. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.022 · Cited by 326
Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke
Cotter, P. E., Martin, P. J., Ring, L., Warburton, E. A., Belham, M., & Pugh, P. J. (2013) · Neurology · doi:10.1212/wnl.0b013e31828f1828 · Cited by 254
Flint, A. C., Banki, N. M., Ren, X., Rao, V. A., & Go, A. S. (2012) · Stroke · doi:10.1161/strokeaha.112.665844 · Cited by 187
Cited by
Heart Disease and Stroke Statistics—2020 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Delling, F. N., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000757 · Cited by 9,175
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2019) · Stroke · doi:10.1161/str.0000000000000211 · Cited by 7,468
Heart disease and stroke statistics-2018 update: a report from the american heart association
Benjamin, E. J., Virani, S. S., Callaway, C. W., Chamberlain, A. M., Chang, A. R., Cheng, S., Chiuve, S. E., Cushman, M., Delling, F. N., Deo, R., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000558 · Cited by 7,146
Self-citation
Metadata
- Authors
- Brachmann, J., Morillo, C. A., Sanna, T., Di Lazzaro, V., Diener, H.-C., Bernstein, R. A., Rymer, M., Ziegler, P. D., Liu, S., & Passman, R. S.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2016-01
- Volume
- 9
- Issue
- 1
- Pages
- e003333-e003333
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2548480191
- Cited by
- 182
- References
- 10
- FWCI
- 17.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uncovering Atrial Fibrillation Beyond Short-Term Monitoring in Cryptogenic Stroke Patients: Three-Year Results From the Cryptogenic Stroke and Underlying Atrial Fibrillation Trial. https://app.cochat.ai/papers/10.1161/circep.115.003333
- The paper
- Brachmann, J., Morillo, C. A., Sanna, T., Di Lazzaro, V., Diener, H.-C., Bernstein, R. A., Rymer, M., Ziegler, P. D., Liu, S., & Passman, R. S. (2016). Uncovering Atrial Fibrillation Beyond Short-Term Monitoring in Cryptogenic Stroke Patients: Three-Year Results From the Cryptogenic Stroke and Underlying Atrial Fibrillation Trial. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.115.003333
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.