The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Evaluating Real-World Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology: Final 2-Year Outcome Data of the EWOLUTION Trial Focusing on History of Stroke and Hemorrhage
Open accessAbstract
Background: Left atrial appendage occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. Evaluating real-life clinical outcomes in atrial fibrillation patients receiving the WATCHMAN left atrial appendage closure technology was designed to collect prospective multicenter outcomes of thromboembolic events, bleeding, and mortality for patients implanted with a WATCHMAN in routine daily practice. Methods: One thousand twenty patients with a WATCHMAN implant procedure were prospectively followed in 47 centers. Left atrial appendage occlusion indication was based on the European Society of Cardiology guidelines. Follow-up and imaging were performed per local practice up to a median follow-up of 2 years. Results: Included population was old (age 73.4±8.9 years), at high risk for stroke (311 prior ischemic stroke/transient ischemic attack and 153 prior hemorrhagic stroke) and bleeding (318 prior major bleeding), with CHA 2 DS 2 -VASc score ≥5 in 49%, hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, Labile international normalized ratio, elderly, drugs/alcohol concomitantly ≥3 in 40% and oral anticoagulation contraindication in 72%. During follow-up, 161 patients (16.4%) died, 22 strokes were observed (1.3/100 patient-years, 83% reduction versus historic data), and 47 major nonprocedural bleeding events (2.7/100 patient-years, 46% reduction versus historic data). Stroke and bleeding rates were consistently lower than historic data in those with prior ischemic (−76% and −41%) or hemorrhagic (−81% and 67%) stroke and prior bleeding (−85% and −30%). Lowest bleeding rates were seen in patients with early discontinuation of dual antiplatelet therapy. Patients with early discontinuation of antithrombotic therapy showed lower bleeding rates, while they were highest for those with prior bleeding. Device thrombus was observed in 34 patients (4.1%) and was not correlated to drug regimen during follow-up ( P =0.28). Conclusions: During the complete 2-year follow-up of Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology, patients with a WATCHMAN left atrial appendage occlusion device had consistently low rates of stroke and nonprocedural bleeding, although most were contraindicated to oral anticoagulation and used only single antiplatelet therapy or nothing. Clinical Trial Registration: URL: https://clinicaltrials.gov . Unique identifier: NCT01972282.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Mehran, R., Rao, S. V., Bhatt, D. L., Gibson, C. M., Caixeta, A., Eikelboom, J., Kaul, S., Wiviott, S. D., Menon, V., Nikolsky, E., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.009449 · Cited by 4,476
Apixaban in patients with atrial fibrillation
Connolly, S. J., Eikelboom, J., Joyner, C., Diener, H.-C., Hart, R., Golitsyn, S., Flaker, G., Avezum, A., Hohnloser, S. H., Diaz, R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1007432 · Cited by 2,483
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationFriberg, L., Rosenqvist, M., & Lip, G. Y. H. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr488 · Cited by 1,192
Lip, G. Y. H., Frison, L., Halperin, J. L., & Lane, D. A. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.024 · Cited by 1,080
5-Year Outcomes After Left Atrial Appendage Closure
Reddy, V. Y., Doshi, S. K., Kar, S., Gibson, D. N., Price, M. J., Huber, K., Horton, R. P., Buchbinder, M., Neuzil, P., Gordon, N. T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.021 · Cited by 1,032
Rivaroxaban for Stroke Prevention after Embolic Stroke of Undetermined Source
Hart, R. G., Sharma, M., Mundl, H., Kasner, S. E., Bangdiwala, S. I., Berkowitz, S. D., Swaminathan, B., Lavados, P., Wang, Y., Wang, Y., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1802686 · Cited by 1,028
Boersma, L. V. A., Schmidt, B., Betts, T. R., Sievert, H., Tamburino, C., Teiger, E., Pokushalov, E., Kische, S., Schmitz, T., Stein, K. M., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv730 · Cited by 522
Self-citationDevice-Related Thrombus After Left Atrial Appendage Closure: Incidence, Predictors, and Outcomes
Dukkipati, S. R., Kar, S., Holmes, D. R., Doshi, S. K., Swarup, V., Gibson, D. N., Maini, B., Gordon, N. T., Main, M. L., & Reddy, V. Y. (2018) · Circulation · doi:10.1161/circulationaha.118.035090 · Cited by 451
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Self-citationCampbell, B. C. V., & Khatri, P. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31179-x · Cited by 1,116
Osmancik, P., Herman, D., Neuzil, P., Hala, P., Taborsky, M., Kala, P., Poloczek, M., Stasek, J., Haman, L., Branny, M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.04.067 · Cited by 646
Chao, T.-F., Joung, B., Takahashi, Y., Lim, T. W., Choi, E.-K., Chan, Y.-H., Guo, Y., Sriratanasathavorn, C., Oh, S., Okumura, K., et al. (2022) · Thrombosis and Haemostasis · doi:10.1055/s-0041-1739411 · Cited by 473
Kar, S., Doshi, S. K., Sadhu, A., Horton, R., Osorio, J., Ellis, C., Stone, J., Shah, M., Dukkipati, S. R., Adler, S., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.050117 · Cited by 414
Metadata
- Authors
- Boersma, L. V., Ince, H., Kische, S., Pokushalov, E., Schmitz, T., Schmidt, B., Gori, T., Meincke, F., Protopopov, A. V., Betts, T., Mazzone, P., Foley, D., Grygier, M., Sievert, H., De Potter, T., Vireca, E., Stein, K., Bergmann, M. W., for the EWOLUTION Investigators, Al Nooryani, A., Fiedler, T., Senatore, G., Brigadeau, F., Defaye, P., Teiger, E., Bonnet, J.-L., Wald, C., Szili-Torok, T., Tschishow, W., Crossland, D., Vahanian, A., Cruz-Gonzalez, I., Thambo, J.-B., Al Smadi, F., Mudra, H., Molitoris, R., Folkeringa, R., Stevenhagen, Y., Gras, D., Tamburino, C., Molon, G., Spence, M., Infante Oliveira, E., Merkulov, E., Sukiennik, A., Wong, T., Busch, M., Boldt, L.-H., Nickenig, G., & Neef, M.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2019-04
- Volume
- 12
- Issue
- 4
- Pages
- e006841-e006841
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2930842499
- Cited by
- 288
- References
- 24
- FWCI
- 24.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluating Real-World Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology: Final 2-Year Outcome Data of the EWOLUTION Trial Focusing on History of Stroke and Hemorrhage. https://app.cochat.ai/papers/10.1161/circep.118.006841
- The paper
- Boersma, L. V., Ince, H., Kische, S., Pokushalov, E., Schmitz, T., Schmidt, B., Gori, T., Meincke, F., Protopopov, A. V., Betts, T., Mazzone, P., Foley, D., Grygier, M., Sievert, H., De Potter, T., Vireca, E., Stein, K., Bergmann, M. W., for the EWOLUTION Investigators, . . . Neef, M. (2019). Evaluating Real-World Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology: Final 2-Year Outcome Data of the EWOLUTION Trial Focusing on History of Stroke and Hemorrhage. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.118.006841
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.