The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study
Open accessAbstract
Background: Left bundle branch pacing (LBBP) is a novel pacing method and has been observed to have low and stable pacing thresholds in prior small short-term studies. The objective of this study was to evaluate the feasibility and safety of LBBP in a large consecutive diverse group of patients with long-term follow-up. Methods: This study prospectively enrolled 632 consecutive pacemaker patients with attempted LBBP from April 2017 to July 2019. Pacing parameters, complications, ECG, and echocardiographic measurements were assessed at implant and during follow-up of 1, 6, 12, and 24 months. Results: LBBP was successful in 618/632 (97.8%) patients according to strict criteria for LBB capture. Mean follow-up time was 18.6±6.7 months. Two hundred thirty-one patients had follow-up over 2 years. LBB capture threshold at implant was 0.65±0.27 mV at 0.5 ms and 0.69±0.24 mV at 0.5 ms at 2-year follow-up. A significant decrease in QRS duration was observed in patients with left bundle branch block (167.22±18.99 versus 124.02±24.15 ms, P <0.001). Postimplantation left ventricular ejection fraction improved in patients with QRS≥120 ms (48.82±17.78% versus 58.12±13.04%, P <0.001). The number of patients with moderate and severe tricuspid regurgitation decreased at 1 year. Permanent right bundle branch injury occurred in 55 (8.9%) patients. LBB capture threshold increased to >3 V or loss of bundle capture in 6 patients (1%), 2 patients of them had a loss of conduction system capture. Two patients required lead revision due to dislodgement. Conclusions: This large observational study suggests that LBBP is feasible with high success rates and low complication rates during long-term follow-up. Therefore, LBBP appears to be a reliable method for physiological pacing for patients with either a bradycardia or heart failure pacing indication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., Leon, A., Yee, R., Marinchak, R. A., Flaker, G., Schron, E., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 997
Self-citationBiventricular Pacing for Atrioventricular Block and Systolic Dysfunction
Curtis, A. B., Worley, S. J., Adamson, P. B., Chung, E. S., Niazi, I., Sherfesee, L., Shinn, T., & St. John Sutton, M. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1210356 · Cited by 854
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., & Ellenbogen, K. A. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.09.013 · Cited by 736
Self-citationA beginner's guide to permanent left bundle branch pacing
Huang, W., Chen, X., Su, L., Wu, S., Xia, X., & Vijayaraman, P. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.06.016 · Cited by 651
Self-citationClinical Outcomes of His Bundle Pacing Compared to Right Ventricular Pacing
Abdelrahman, M., Subzposh, F. A., Beer, D., Durr, B., Naperkowski, A., Sun, H., Oren, J. W., Dandamudi, G., & Vijayaraman, P. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.02.048 · Cited by 589
Lustgarten, D. L., Crespo, E. M., Arkhipova-Jenkins, I., Lobel, R., Winget, J., Koehler, J., Liberman, E., & Sheldon, T. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.03.048 · Cited by 415
Vijayaraman, P., Subzposh, F. A., Naperkowski, A., Panikkath, R., John, K., Mascarenhas, V., Bauch, T. D., & Huang, W. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.05.011 · Cited by 396
Self-citationUpadhyay, G. A., Cherian, T., Shatz, D. Y., Beaser, A. D., Aziz, Z., Ozcan, C., Broman, M. T., Nayak, H. M., & Tung, R. (2019) · Circulation · doi:10.1161/circulationaha.118.038648 · Cited by 350
Huang, W., Wu, S., Vijayaraman, P., Su, L., Chen, X., Cai, B., Zou, J., Lan, R., Fu, G., Mao, G., et al. (2020) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2020.04.011 · Cited by 287
Self-citationLong-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., Mao, G., Vijayaraman, P., & Ellenbogen, K. A. (2019) · Heart · doi:10.1136/heartjnl-2018-313415 · Cited by 268
Self-citationPermanent His-bundle pacing: a systematic literature review and meta-analysis
Zanon, F., Ellenbogen, K. A., Dandamudi, G., Sharma, P. S., Huang, W., Lustgarten, D. L., Tung, R., Tada, H., Koneru, J. N., Bergemann, T., et al. (2018) · EP Europace · doi:10.1093/europace/euy058 · Cited by 263
Self-citationWu, S., Su, L., Vijayaraman, P., Zheng, R., Cai, M., Xu, L., Shi, R., Huang, Z., Whinnett, Z. I., & Huang, W. (2021) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.04.037 · Cited by 263
Self-citationLi, X., Li, H., Ma, W., Ning, X., Liang, E., Pang, K., Yao, Y., Hua, W., Zhang, S., & Fan, X. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.04.043 · Cited by 246
Arnold, A. D., Shun-Shin, M. J., Keene, D., Howard, J. P., Sohaib, S. M. A., Wright, I. J., Cole, G. D., Qureshi, N. A., Lefroy, D. C., Koa-Wing, M., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.073 · Cited by 237
Self-citationHou, X., Qian, Z., Wang, Y., Qiu, Y., Chen, X., Jiang, H., Jiang, Z., Wu, H., Zhao, Z., Zhou, W., et al. (2019) · EP Europace · doi:10.1093/europace/euz188 · Cited by 229
Self-citationAjijola, O. A., Upadhyay, G. A., Macias, C., Shivkumar, K., & Tung, R. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.04.003 · Cited by 210
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., & Ellenbogen, K. A. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.116.005309 · Cited by 208
Self-citationComputer Three-Dimensional Reconstruction of the Sinoatrial Node
Dobrzynski, H., Li, J., Tellez, J., Greener, I. D., Nikolski, V. P., Wright, S. E., Parson, S. H., Jones, S. A., Lancaster, M. K., Yamamoto, M., et al. (2005) · Circulation · doi:10.1161/01.cir.0000152100.04087.db · Cited by 181
Keene, D., Arnold, A. D., Jastrzębski, M., Burri, H., Zweibel, S., Crespo, E., Chandrasekaran, B., Bassi, S., Joghetaei, N., Swift, M., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14064 · Cited by 176
Self-citationElectrophysiologic Insights Into Site of Atrioventricular Block
Vijayaraman, P., Naperkowski, A., Ellenbogen, K. A., & Dandamudi, G. (2015) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2015.09.012 · Cited by 173
Self-citationSharma, P. S., Naperkowski, A., Bauch, T. D., Chan, J. Y. S., Arnold, A. D., Whinnett, Z. I., Ellenbogen, K. A., & Vijayaraman, P. (2018) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006613 · Cited by 170
Self-citationChen, X., Wu, S., Su, L., Su, Y., & Huang, W. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13956 · Cited by 150
Self-citationShan, P., Su, L., Zhou, X., Wu, S., Xu, L., Xiao, F., Zhou, X., Ellenbogen, K. A., & Huang, W. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.10.031 · Cited by 118
Self-citationLeft bundle branch pacing is the best approach to physiological pacing
Padala, S. K., & Ellenbogen, K. A. (2020) · Heart Rhythm O2 · doi:10.1016/j.hroo.2020.03.002 · Cited by 118
Self-citationVijayaraman, P., Dandamudi, G., Worsnick, S. A., & Ellenbogen, K. A. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12571 · Cited by 113
Self-citationWang, S., Wu, S., Xu, L., Xiao, F., Whinnett, Z. I., Vijayaraman, P., Su, L., & Huang, W. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.014253 · Cited by 95
Self-citationSu, L., Xu, T., Cai, M., Xu, L., Vijayaraman, P., Sharma, P. S., Chen, X., Zheng, R., Wu, S., & Huang, W. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14377 · Cited by 70
Self-citationWu, S., Sharma, P. S., & Huang, W. (2020) · EP Europace · doi:10.1093/europace/euaa297 · Cited by 67
Self-citationSu, L., Wu, S., Wang, S., Wang, Z., Xiao, F., Shan, P., Zhou, H., Huang, Z., Xu, L., & Huang, W. (2018) · EP Europace · doi:10.1093/europace/euy281 · Cited by 65
Self-citationShort‐term and intermediate‐term performance and safety of left bundle branch pacing
Guo, J., Li, L., Meng, F., Su, M., Huang, X., Chen, S., Li, Q., Chang, D., & Cai, B. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14463 · Cited by 34
His-bundle pacing is the best approach to physiological pacing
Upadhyay, G. A., Razminia, P., & Tung, R. H. (2020) · Heart Rhythm O2 · doi:10.1016/j.hroo.2020.03.001 · Cited by 25
Cited by
Chung, M. K., Patton, K. K., Lau, C.-P., Dal Forno, A. R. J., Al-Khatib, S. M., Arora, V., Birgersdotter-Green, U. M., Cha, Y.-M., Chung, E. H., Cronin, E. M., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1538 · Cited by 548
Self-citationLeft bundle branch area pacing outcomes: the multicentre European MELOS study
Jastrzębski, M., Kiełbasa, G., Cano, O., Curila, K., Heckman, L., De Pooter, J., Chovanec, M., Rademakers, L., Huybrechts, W., Grieco, D., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac445 · Cited by 517
Self-citationBurri, H., Jastrzebski, M., Cano, Ó., Čurila, K., de Pooter, J., Huang, W., Israel, C., Joza, J., Romero, J., Vernooy, K., et al. (2023) · Europace · doi:10.1093/europace/euad043 · Cited by 432
Self-citationSharma, P. S., Patel, N. R., Ravi, V., Zalavadia, D. V., Dommaraju, S., Garg, V., Larsen, T. R., Naperkowski, A. M., Wasserlauf, J., Krishnan, K., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2021.08.033 · Cited by 255
Metadata
- Authors
- Su, L., Wang, S., Wu, S., Xu, L., Huang, Z., Chen, X., Zheng, R., Jiang, L., Ellenbogen, K. A., Whinnett, Z. I., & Huang, W.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2021-02
- Volume
- 14
- Issue
- 2
- Pages
- e009261-e009261
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W3119843763
- Cited by
- 327
- References
- 31
- FWCI
- 38.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.