CoChat

Pulsatility and the Risk of Nonsurgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate II

Open access
Wever-Pinzon, Omar, Selzman, Craig H., Drakos, Stavros G., Saidi, Abdulfattah, Stoddard, Gregory J., Gilbert, Edward M., Labedi, Mohamed, Reid, Bruce B., Davis, Erin S., Kfoury, Abdallah G., Li, Dean Y., Stehlik, Josef, Bader, Feras · 2013 · Circulation: Heart Failure
Cited by 233

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Background—: Bleeding is an important cause of morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs). Reduced pulsatility has been implicated as a contributing cause. The aim of this study was to assess the effects of different degrees of pulsatility on the incidence of nonsurgical bleeding. Methods and Results—: The Utah Transplantation Affiliated Hospitals (U.T.A.H.) heart failure and transplant program databases were queried for patients with end-stage heart failure who required support with the continuous-flow LVAD HeartMate II (Thoratec Corp, Pleasanton, CA) between 2004 and 2012. Pulsatility was evaluated by means of the LVAD parameter pulsatility index (PI) and by the echocardiographic assessment of aortic valve opening during the first 3 months of LVAD support. PI was analyzed as a continuous variable and also stratified according to tertiles of all the PI measurements during the study period (low PI: <4.6, intermediate PI: 4.6–5.2, and high PI: >5.2). Major nonsurgical bleeding associated with a decrease in hemoglobin ≥2 g/dL (in the absence of hemolysis) was the primary end point. A total of 134 patients (median age of 60 [interquartile range: 49–68] years, 78% men) were included. Major bleeding occurred in 33 (25%) patients (70% gastrointestinal, 21% epistaxis, 3% genitourinary, and 6% intracranial). In multivariable analysis, PI examined either as a categorical variable, low versus high PI (hazard ratio, 4.06; 95% confidence interval, 1.35–12.21; P =0.04), or as a continuous variable (hazard ratio, 0.60; 95% confidence interval, 0.40–0.92; P =0.02) was associated with an increased risk of bleeding. Conclusions—: Reduced pulsatility in patients supported with the continuous-flow LVAD HeartMate II is associated with an increased risk of nonsurgical bleeding, as evaluated by PI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.112.000206

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 233

Metadata

Authors
Wever-Pinzon, O., Selzman, C. H., Drakos, S. G., Saidi, A., Stoddard, G. J., Gilbert, E. M., Labedi, M., Reid, B. B., Davis, E. S., Kfoury, A. G., Li, D. Y., Stehlik, J., & Bader, F.
Venue
Circulation: Heart Failure
Published
2013-05
Volume
6
Issue
3
Pages
517-526
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2121626542
Cited by
233
References
23
FWCI
12.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulsatility and the Risk of Nonsurgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate II. https://app.cochat.ai/papers/10.1161/circheartfailure.112.000206
The paper
Wever-Pinzon, O., Selzman, C. H., Drakos, S. G., Saidi, A., Stoddard, G. J., Gilbert, E. M., Labedi, M., Reid, B. B., Davis, E. S., Kfoury, A. G., Li, D. Y., Stehlik, J., & Bader, F. (2013). Pulsatility and the Risk of Nonsurgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate II. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.112.000206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.