Pulsatility and the Risk of Nonsurgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate II
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background—: Bleeding is an important cause of morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs). Reduced pulsatility has been implicated as a contributing cause. The aim of this study was to assess the effects of different degrees of pulsatility on the incidence of nonsurgical bleeding. Methods and Results—: The Utah Transplantation Affiliated Hospitals (U.T.A.H.) heart failure and transplant program databases were queried for patients with end-stage heart failure who required support with the continuous-flow LVAD HeartMate II (Thoratec Corp, Pleasanton, CA) between 2004 and 2012. Pulsatility was evaluated by means of the LVAD parameter pulsatility index (PI) and by the echocardiographic assessment of aortic valve opening during the first 3 months of LVAD support. PI was analyzed as a continuous variable and also stratified according to tertiles of all the PI measurements during the study period (low PI: <4.6, intermediate PI: 4.6–5.2, and high PI: >5.2). Major nonsurgical bleeding associated with a decrease in hemoglobin ≥2 g/dL (in the absence of hemolysis) was the primary end point. A total of 134 patients (median age of 60 [interquartile range: 49–68] years, 78% men) were included. Major bleeding occurred in 33 (25%) patients (70% gastrointestinal, 21% epistaxis, 3% genitourinary, and 6% intracranial). In multivariable analysis, PI examined either as a categorical variable, low versus high PI (hazard ratio, 4.06; 95% confidence interval, 1.35–12.21; P =0.04), or as a continuous variable (hazard ratio, 0.60; 95% confidence interval, 0.40–0.92; P =0.02) was associated with an increased risk of bleeding. Conclusions—: Reduced pulsatility in patients supported with the continuous-flow LVAD HeartMate II is associated with an increased risk of nonsurgical bleeding, as evaluated by PI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181 · cited 1×
“Cumulative survival free from nonsurgical bleeding were estimated using Kaplan–Meier survival analysis and compared between groups with the log-rank test.(26,27) Survival free from nonsurgical bleeding was evaluated for the first 3 months after LVAD implantation.”
MethodRegression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Evaluation of survival data and two new rank order statistics arising in its consideration.
Mantel, N. (1966) · PubMed · Cited by 7,519
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Eikelboom, J. W., Wallentin, L., Connolly, S. J., Ezekowitz, M., Healey, J. S., Oldgren, J., Yang, S., Alings, M., Kaatz, S., Hohnloser, S. H., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.004747 · Cited by 1,081
Uriel, N. Y., Pak, S., Jorde, U. P., Jude, B., Susen, S., Vincentelli, A., Ennezat, P. V., Cappleman, S., Naka, Y., & MANCINI, D. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.016 · Cited by 607
Crow, S., John, R., Boyle, A., Shumway, S., Liao, K., Colvin-Adams, M., Toninato, C., Missov, E., Pritzker, M., Martin, C., et al. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.07.032 · Cited by 486 · cited 1×
“8 events/100 years).(31) However, the incidence of”
Starling, R. C., Naka, Y., Boyle, A. J., Gonzalez-Stawinski, G., John, R., Jorde, U., Russell, S. D., Conte, J. V., Aaronson, K. D., McGee, E. C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.062 · Cited by 452
The Fourth INTERMACS Annual Report: 4,000 implants and counting
Kirklin, J. K., Naftel, D. C., Kormos, R. L., Stevenson, L. W., Pagani, F. D., Miller, M. A., Baldwin, J. T., & Young, J. B. (2012) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2011.12.001 · Cited by 392
Acquired von Willebrand Syndrome in Continuous-Flow Ventricular Assist Device Recipients
Crow, S. S., Chen, D., Milano, C. A., Thomas, W., Joyce, L. D., Piacentino, V., Sharma, R., Wu, J. R., Arepally, G. M., Bowles, D. E., et al. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.04.099 · Cited by 388 · cited 1×
“This phenomenon, while frequently observed in patients with CF-LVADs (and almost universal in axial-flow LVADs), does not by itself explain the high variability of bleeding events among different patients on CF-LVAD support, suggesting that additional mechanisms might be involved.(14) We believe that one such mechanis…”
BackgroundSecond INTERMACS annual report: More than 1,000 primary left ventricular assist device implants
Kirklin, J. K., Naftel, D. C., Kormos, R. L., Stevenson, L. W., Pagani, F. D., Miller, M. A., Ulisney, K. L., Baldwin, J. T., & Young, J. B. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2009.10.009 · Cited by 386
The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients
Cowger, J., Pagani, F. D., Haft, J. W., Romano, M. A., Aaronson, K. D., & Kolias, T. J. (2010) · Circulation: Heart Failure · doi:10.1161/circheartfailure.109.917765 · Cited by 361
Demirozu, Z. T., Radovancevic, R., Hochman, L. F., Gregoric, I. D., Letsou, G. V., Kar, B., Bogaev, R. C., & Frazier, O. H. (2011) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2011.03.008 · Cited by 356 · cited 5×
“Similar to other studies, we observed a high incidence of bleeding complications in patients with CF-LVADs.11,18,19,29,30 Twenty-five percent of our patients were affected by a major bleeding event.”
BackgroundResultInfluentialGeisen, U., Heilmann, C., Beyersdorf, F., Benk, C., Berchtold-Herz, M., Schlensak, C., Budde, U., & Zieger, B. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2007.12.047 · Cited by 331
Multicenter Evaluation of an Intrapericardial Left Ventricular Assist System
Strueber, M., O’Driscoll, G., Jansz, P., Khaghani, A., Levy, W. C., & Wieselthaler, G. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.040 · Cited by 266
Letsou, G. V., Shah, N., Gregoric, I. D., Myers, T. J., Delgado, R., & Frazier, O. H. (2005) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2003.10.018 · Cited by 217
Souto, J. C., Almasy, L., Muñiz-Diaz, E., Soria, J. M., Borrell, M., Bayén, L., Mateo, J., Madoz, P., Stone, W., Blangero, J., et al. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.8.2024 · Cited by 210 · cited 1×
“It has been previously shown that patients with blood type O have lower levels of measured von Willebrand factor and factor VIII; however, in our study the presence of blood type O was not associated with an increased risk of bleeding.(40) Although not significant after multivariable adjustment, the following addition…”
ResultWinkelmayer, W. C., Levin, R., & Avorn, J. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2003.50026 · Cited by 72 · cited 1×
“Patient age and history of chronic kidney disease have been previously linked with an increased bleeding risk in different clinical settings.(41,42) The association between severe RV dysfunction and increased bleeding risk could be related to a more advanced stage of HF in patients with severe RV dysfunction.”
BackgroundMidterm experience with the Jarvik 2000 axial flow left ventricular assist device
Haj‐Yahia, S., Birks, E. J., Rogers, P., Bowles, C. T., Hipkins, M., George, R. S., Amrani, M., Petrou, M., Pepper, J., Dreyfus, G., et al. (2007) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.01.002 · Cited by 67
Cited by
Cardiac Recovery During Long-Term Left Ventricular Assist Device Support
Wever-Pinzon, O., Drakos, S. G., McKellar, S. H., Horne, B. D., Caine, W. T., Kfoury, A. G., Li, D. Y., Fang, J. C., Stehlik, J., & Selzman, C. H. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.07.743 · Cited by 208
Self-citationThe vexing problem of thrombosis in long-term mechanical circulatory support
Mehra, M. R., Stewart, G. C., & Uber, P. A. (2014) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2013.12.002 · Cited by 185
Metadata
- Authors
- Wever-Pinzon, O., Selzman, C. H., Drakos, S. G., Saidi, A., Stoddard, G. J., Gilbert, E. M., Labedi, M., Reid, B. B., Davis, E. S., Kfoury, A. G., Li, D. Y., Stehlik, J., & Bader, F.
- Venue
- Circulation: Heart Failure
- Published
- 2013-05
- Volume
- 6
- Issue
- 3
- Pages
- 517-526
- ISSN
- 1941-3289 (ISSN-L)
- 1941-3297
- OpenAlex
- W2121626542
- Cited by
- 233
- References
- 23
- FWCI
- 12.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.