The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Novel Wearable Seismocardiography and Machine Learning Algorithms Can Assess Clinical Status of Heart Failure Patients
Open accessAbstract
Background: Remote monitoring of patients with heart failure (HF) using wearable devices can allow patient-specific adjustments to treatments and thereby potentially reduce hospitalizations. We aimed to assess HF state using wearable measurements of electrical and mechanical aspects of cardiac function in the context of exercise. Methods and Results: Patients with compensated (outpatient) and decompensated (hospitalized) HF were fitted with a wearable ECG and seismocardiogram sensing patch. Patients stood at rest for an initial recording, performed a 6-minute walk test, and then stood at rest for 5 minutes of recovery. The protocol was performed at the time of outpatient visit or at 2 time points (admission and discharge) during an HF hospitalization. To assess patient state, we devised a method based on comparing the similarity of the structure of seismocardiogram signals after exercise compared with rest using graph mining (graph similarity score). We found that graph similarity score can assess HF patient state and correlates to clinical improvement in 45 patients (13 decompensated, 32 compensated). A significant difference was found between the groups in the graph similarity score metric (44.4±4.9 [decompensated HF] versus 35.2±10.5 [compensated HF]; P <0.001). In the 6 decompensated patients with longitudinal data, we found a significant change in graph similarity score from admission (decompensated) to discharge (compensated; 44±4.1 [admitted] versus 35±3.9 [discharged]; P <0.05). Conclusions: Wearable technologies recording cardiac function and machine learning algorithms can assess compensated and decompensated HF states by analyzing cardiac response to submaximal exercise. These techniques can be tested in the future to track the clinical status of outpatients with HF and their response to pharmacological interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The fundamental frequency of 410.7 ± 47.9 (Supplementary Fig.24e) is consistent with published results46.”
From Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units (2020) · cites this paper as [46]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jain, A. K., Murty, M. N., & Flynn, P. J. (1999) · ACM Computing Surveys · doi:10.1145/331499.331504 · Cited by 13,925
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
(2006) · Springer eBooks · Cited by 8,123
The fast Fourier transform and its applications
(1989) · Choice Reviews Online · doi:10.5860/choice.26-3285 · Cited by 2,118
Cleland, J. G. F. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00823-0 · Cited by 1,553
Dharmarajan, K., Hsieh, A., Lin, Z., Bueno, H., Ross, J. S., Horwitz, L. I., Barreto-Filho, J. A. S., Kim, N. V., Bernheim, S. M., Suter, L. G., et al. (2013) · JAMA · doi:10.1001/jama.2012.216476 · Cited by 1,059
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Self-citationCahalin, L. P., Mathier, M. A., Semigran, M. J., Dec, G. W., & DiSalvo, T. G. (1996) · CHEST Journal · doi:10.1378/chest.110.2.325 · Cited by 761
Intrathoracic Impedance Monitoring in Patients With Heart Failure
Yu, C., Wang, L., Chau, E. M. C., Chan, R. H.-W., Kong, S., TANG, M., Christensen, J., Stadler, R. W., & Lau, C. (2005) · Circulation · doi:10.1161/circulationaha.104.492207 · Cited by 708
Research works printed but not linked: 2
- Brigham EOThe Fast Fourier Transform a nd Its Applications. Englewood Cliffs, NJ: Prentice Hall; 1988.
- Bishop CMPattern R ecognition and Machine Learning (Information Science and Statistics). New York, NY: Springer-Verlag; 2006.
Cited by
Sorted by citations
Items 201–207 of 207
Neural Style Transfer-Based Denoising of Seismocardiogram Signals Under Dynamic Conditions
Moradi, D., Kizir, B., & Semiz, B. (2026) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2026.3688416
Teckchandani, T. A., Neary, J. P., Norrie, H. J., Flegel, K. P., Maguire, K. Q., Krätzig, G. P., & Carleton, R. N. (2026) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/cjpp-2026-0116
Singh, Y. O., Singha, S., Sharma, L. N., & Dandapat, S. (2026) · IEEE Guwahati Subsection Conference (GCON) · doi:10.1109/gcon69192.2026.11648431
Singha, S., Sharma, L. N., & Dandapat, S. (2026) · IEEE Guwahati Subsection Conference (GCON) · doi:10.1109/gcon69192.2026.11648849
Sieciński, S. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-37739-5_21
Gamage, P. T., Weerasinghe, Y., Weerasinghe, P., & Kaya, M. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04366-5
Metadata
- Authors
- Inan, O. T., Baran Pouyan, M., Javaid, A. Q., Dowling, S., Etemadi, M., Dorier, A., Heller, J. A., Bicen, A. O., Roy, S., De Marco, T., & Klein, L.
- Affiliations
- Northwestern University (US)
- From the School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta (O.T.I., M.B.P., A.Q.J., A.D., A.O.B.); Division of Cardiology (S.D., T.D.M., L.K.) and Department of Bioengineering and Therapeutic Sciences (S.R.), University of California, San Francisco; and Department of Anesthesiology and Department of Biomedical Engineering, Northwestern University, Chicago, IL (M.E., J.A.H.).
- ORCID
- Venue
- Circulation: Heart Failure
- Published
- 2018-01
- Volume
- 11
- Issue
- 1
- Pages
- e004313-e004313
- ISSN
- 1941-3289 (ISSN-L)
- 1941-3297
- PMC
- PMC5769154
- OpenAlex
- W2783795641
- Cited by
- 207
- References
- 33
- Citations by year
- 2026: 8 · 2025: 23 · 2024: 26 · 2023: 21 · 2022: 36 · 2021: 29 · 2020: 39 · 2019: 18 · 2018: 7
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Circulation Heart Failure (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Institute on Aging (R56AG048458)
- National Heart, Lung, and Blood Institute (R01HL130619)
- National Institute of General Medical Sciences (T32GM007618)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- heart failure, seismocardiography, wearable sensors, remote patient monitoring, acute decompensated heart failure, submaximal exercise, 6-minute walk test, cardiac function, machine learning
- MeSH terms
- Machine Learning, Wearable Electronic Devices, Adult, Aged, Algorithms, Electrocardiography, Equipment Design, Female, Heart Failure, Humans, Kinetocardiography, Male, Middle Aged, Exercise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›