The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Rapid 3D Phenotyping of Cardiovascular Development in Mouse Embryos by Micro-CT With Iodine Staining
Open accessAbstract
Background— Microcomputed tomography (micro-CT) has been used extensively in research to generate high-resolution 3D images of calcified tissues in small animals nondestructively. It has been especially useful for the characterization of skeletal mutations but limited in its utility for the analysis of soft tissue such as the cardiovascular system. Visualization of the cardiovascular system has been largely restricted to structures that can be filled with radiopaque intravascular contrast agents in adult animals. Recent ex vivo studies using osmium tetroxide, iodinated contrast agents, inorganic iodine, and phosphotungstic acid have demonstrated the ability to stain soft tissues differentially, allowing for high intertissue contrast in micro-CT images. In the present study, we demonstrate the application of this technology for visualization of cardiovascular structures in developing mouse embryos using Lugol solution (aqueous potassium iodide plus iodine). Methods and Results— We show the optimization of this method to obtain ex vivo micro-CT images of embryonic and neonatal mice with excellent soft-tissue contrast. We demonstrate the utility of this method to visualize key structures during cardiovascular development at various stages of embryogenesis. Our method benefits from the ease of sample preparation, low toxicity, and low cost. Furthermore, we show how multiple cardiac defects can be demonstrated by micro-CT in a single specimen with a known genetic lesion. Indeed, a previously undescribed cardiac venous abnormality is revealed in a PlexinD1 mutant mouse. Conclusions— Micro-CT of iodine-stained tissue is a valuable technique for the characterization of cardiovascular development and defects in mouse models of congenital heart disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crank, J. (1956) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,978
The incidence of congenital heart disease.
Hoffman, J. I. E., & Kaplan, S. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01886-7 · Cited by 6,099
Metscher, B. D. (2009) · Developmental Dynamics · doi:10.1002/dvdy.21857 · Cited by 607
PlexinD1 and Semaphorin Signaling Are Required in Endothelial Cells for Cardiovascular Development
Gitler, A. D., Lu, M. M., & Epstein, J. A. (2004) · Developmental Cell · doi:10.1016/j.devcel.2004.06.002 · Cited by 371
Self-citationPalmer, A. W., Guldberg, R. E., & Levenston, M. E. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606406103 · Cited by 291
Morphologic Phenotyping with MR Microscopy: The Visible Mouse
Johnson, G. A., Cofer, G. P., Gewalt, S. L., & Hedlund, L. W. (2002) · Radiology · doi:10.1148/radiol.2223010531 · Cited by 249
Echocardiographic Assessment of Left Ventricular Mass and Systolic Function in Mice
Gardin, J. M., Siri, F. M., Kitsis, R. N., Edwards, J. G., & Leinwand, L. A. (1995) · Circulation Research · doi:10.1161/01.res.76.5.907 · Cited by 220
Fundamental image quality limits for microcomputed tomography in small animals
Ford, N. L., Thornton, M. M., & Holdsworth, D. W. (2003) · Medical Physics · doi:10.1118/1.1617353 · Cited by 210
Virtual Histology of Transgenic Mouse Embryos for High-Throughput Phenotyping
Johnson, J. T., Hansen, M. S., Wu, I., Healy, L. J., Johnson, C. R., Jones, G. M., Capecchi, M. R., & Keller, C. (2006) · PLoS Genetics · doi:10.1371/journal.pgen.0020061 · Cited by 182
Molecular imaging in small animals?roles for micro-CT
Ritman, E. L. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10415 · Cited by 153
Cited by
Gignac, P. M., Kley, N. J., Clarke, J. A., Colbert, M. W., Morhardt, A. C., Cerio, D., Cost, I. N., Cox, P. G., Daza, J. D., Early, C. M., et al. (2016) · Journal of Anatomy · doi:10.1111/joa.12449 · Cited by 541
PAUWELS, E., VAN LOO, D., CORNILLIE, P., BRABANT, L., & VAN HOOREBEKE, L. (2013) · Journal of Microscopy · doi:10.1111/jmi.12013 · Cited by 212
Hemodynamic patterning of the avian atrioventricular valve
Yalcin, H. C., Shekhar, A., McQuinn, T. C., & Butcher, J. T. (2011) · Developmental Dynamics · doi:10.1002/dvdy.22512 · Cited by 72
HANDSCHUH, S., BEISSER, C. J., RUTHENSTEINER, B., & METSCHER, B. D. (2017) · Journal of Microscopy · doi:10.1111/jmi.12543 · Cited by 48
Metadata
- Authors
- Degenhardt, K., Wright, A. C., Horng, D., Padmanabhan, A., & Epstein, J. A.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2010-05
- Volume
- 3
- Issue
- 3
- Pages
- 314-322
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2044528153
- Cited by
- 267
- References
- 22
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid 3D Phenotyping of Cardiovascular Development in Mouse Embryos by Micro-CT With Iodine Staining. https://app.cochat.ai/papers/10.1161/circimaging.109.918482
- The paper
- Degenhardt, K., Wright, A. C., Horng, D., Padmanabhan, A., & Epstein, J. A. (2010). Rapid 3D Phenotyping of Cardiovascular Development in Mouse Embryos by Micro-CT With Iodine Staining. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.109.918482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.