CoChat

Improved Left Ventricular Mass Quantification With Partial Voxel Interpolation: In Vivo and Necropsy Validation of a Novel Cardiac MRI Segmentation Algorithm

Open access
Codella, Noel C.F., Lee, Hae Yeoun, Fieno, David S., Chen, Debbie W., Hurtado-Rua, Sandra, Kochar, Minisha, Finn, John Paul, Judd, Robert, Goyal, Parag, Schenendorf, Jesse, Cham, Matthew D., Devereux, Richard B., Prince, Martin, Wang, Yi, Weinsaft, Jonathan W. · 2012 · Circulation: Cardiovascular Imaging
Cited by 56

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background—: Cardiac magnetic resonance (CMR) typically quantifies LV mass (LVM) by means of manual planimetry (MP), but this approach is time-consuming and does not account for partial voxel components— myocardium admixed with blood in a single voxel. Automated segmentation (AS) can account for partial voxels, but this has not been used for LVM quantification. This study used automated CMR segmentation to test the influence of partial voxels on quantification of LVM. Methods and Results—: LVM was quantified by AS and MP in 126 consecutive patients and 10 laboratory animals undergoing CMR. AS yielded both partial voxel (AS PV ) and full voxel (AS FV ) measurements. Methods were independently compared with LVM quantified on echocardiography (echo) and an ex vivo standard of LVM at necropsy. AS quantified LVM in all patients, yielding a 12-fold decrease in processing time versus MP (0:21±0:04 versus 4:18±1:02 minutes; P <0.001). AS FV mass (136±35 g) was slightly lower than MP (139±35; Δ=3±9 g, P <0.001). Both methods yielded similar proportions of patients with LV remodeling ( P =0.73) and hypertrophy ( P =1.00). Regarding partial voxel segmentation, AS PV yielded higher LVM (159±38 g) than MP (Δ=20±10 g) and AS FV (Δ=23±6 g, both P <0.001), corresponding to relative increases of 14% and 17%. In multivariable analysis, magnitude of difference between AS PV and AS FV correlated with larger voxel size (partial r =0.37, P <0.001) even after controlling for LV chamber volume ( r =0.28, P =0.002) and total LVM ( r =0.19, P =0.03). Among patients, AS PV yielded better agreement with echo (Δ=20±25 g) than did AS FV (Δ=43±24 g) or MP (Δ=40±22 g, both P <0.001). Among laboratory animals, AS PV and ex vivo results were similar (Δ=1±3 g, P =0.3), whereas AS FV (6±3 g, P <0.001) and MP (4±5 g, P =0.02) yielded small but significant differences with LVM at necropsy. Conclusions—: Automated segmentation of myocardial partial voxels yields a 14–17% increase in LVM versus full voxel segmentation, with increased differences correlated with lower spatial resolution. Partial voxel segmentation yields improved CMR agreement with echo and necropsy-verified LVM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.111.966754

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Codella, N. C. F., Lee, H. Y., Fieno, D. S., Chen, D. W., Hurtado-Rua, S., Kochar, M., Finn, J. P., Judd, R., Goyal, P., Schenendorf, J., Cham, M. D., Devereux, R. B., Prince, M., Wang, Y., & Weinsaft, J. W.
Venue
Circulation: Cardiovascular Imaging
Published
2012-01
Volume
5
Issue
1
Pages
137-146
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2155396404
Cited by
56
References
1
FWCI
3.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.