CoChat

In Vivo Mononuclear Cell Tracking Using Superparamagnetic Particles of Iron Oxide: Feasibility and Safety in Humans

Open access
Richards, Jennifer M.J., Shaw, Catherine A., Lang, Ninian N., Williams, Michelle C., Semple, Scott I.K., MacGillivray, Thomas J., Gray, Calum, Crawford, Julie H., Alam, Shirjel R., Atkinson, Anne P.M., Forrest, Elaine K., Bienek, Carol, Mills, Nicholas L., Burdess, Anne, Dhaliwal, Kev, Simpson, A. John, Wallace, William A., Hill, Adam T., Roddie, P. Huw, McKillop, Graham, Connolly, Thomas A., Feuerstein, Giora Z., Barclay, G. Robin, Turner, Marc L., Newby, David E. · 2012 · Circulation: Cardiovascular Imaging
Cited by 118

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background—: Cell therapy is an emerging and exciting novel treatment option for cardiovascular disease that relies on the delivery of functional cells to their target site. Monitoring and tracking cells to ensure tissue delivery and engraftment is a critical step in establishing clinical and therapeutic efficacy. The study aims were (1) to develop a Good Manufacturing Practice–compliant method of labeling competent peripheral blood mononuclear cells with superparamagnetic particles of iron oxide (SPIO), and (2) to evaluate its potential for magnetic resonance cell tracking in humans. Methods and Results—: Peripheral blood mononuclear cells 1–5×10 9 were labeled with SPIO. SPIO-labeled cells had similar in vitro viability, migratory capacity, and pattern of cytokine release to unlabeled cells. After intramuscular administration, up to 10 8 SPIO-labeled cells were readily identifiable in vivo for at least 7 days using magnetic resonance imaging scanning. Using a phased-dosing study, we demonstrated that systemic delivery of up to 10 9 SPIO-labeled cells in humans is safe, and cells accumulating in the reticuloendothelial system were detectable on clinical magnetic resonance imaging. In a healthy volunteer model, a focus of cutaneous inflammation was induced in the thigh by intradermal injection of tuberculin. Intravenously delivered SPIO-labeled cells tracked to the inflamed skin and were detectable on magnetic resonance imaging. Prussian blue staining of skin biopsies confirmed iron-laden cells in the inflamed skin. Conclusions—: Human peripheral blood mononuclear cells can be labeled with SPIO without affecting their viability or function. SPIO labeling for magnetic resonance cell tracking is a safe and feasible technique that has major potential for a range of cardiovascular applications including monitoring of cell therapies and tracking of inflammatory cells. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov ; Unique identifier: NCT00972946, NCT01169935.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.112.972596

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 118

Metadata

Authors
Richards, J. M. J., Shaw, C. A., Lang, N. N., Williams, M. C., Semple, S. I. K., MacGillivray, T. J., Gray, C., Crawford, J. H., Alam, S. R., Atkinson, A. P. M., Forrest, E. K., Bienek, C., Mills, N. L., Burdess, A., Dhaliwal, K., Simpson, A. J., Wallace, W. A., Hill, A. T., Roddie, P. H., McKillop, G., Connolly, T. A., Feuerstein, G. Z., Barclay, G. R., Turner, M. L., & Newby, D. E.
Venue
Circulation: Cardiovascular Imaging
Published
2012-07
Volume
5
Issue
4
Pages
509-517
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2147741687
Cited by
118
References
2
FWCI
6.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Mononuclear Cell Tracking Using Superparamagnetic Particles of Iron Oxide: Feasibility and Safety in Humans. https://app.cochat.ai/papers/10.1161/circimaging.112.972596
The paper
Richards, J. M. J., Shaw, C. A., Lang, N. N., Williams, M. C., Semple, S. I. K., MacGillivray, T. J., Gray, C., Crawford, J. H., Alam, S. R., Atkinson, A. P. M., Forrest, E. K., Bienek, C., Mills, N. L., Burdess, A., Dhaliwal, K., Simpson, A. J., Wallace, W. A., Hill, A. T., Roddie, P. H., . . . Newby, D. E. (2012). In Vivo Mononuclear Cell Tracking Using Superparamagnetic Particles of Iron Oxide: Feasibility and Safety in Humans. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.112.972596

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.