The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Aortic Dilation in Bicuspid Aortic Valve Disease: Flow Pattern Is a Major Contributor and Differs With Valve Fusion Type
Open accessAbstract
Background—: Ascending aortic dilation is important in bicuspid aortic valve (BAV) disease, with increased risk of aortic dissection. We used cardiovascular MR to understand the pathophysiology better by examining the links between 3-dimensional flow abnormalities, aortic function, and aortic dilation. Methods and Results—: A total of 142 subjects underwent cardiovascular MR (mean age, 40 years; 95 with BAV, 47 healthy volunteers). Patients with BAV had predominantly abnormal right-handed helical flow in the ascending aorta, larger ascending aortas (18.3±3.3 versus 15.2±2.2 mm/m 2 ; P <0.001), and higher rotational (helical) flow (31.7±15.8 versus 2.9±3.9 mm 2 /s; P <0.001), systolic flow angle (23.1°±12.5° versus 7.0°±4.6°; P <0.001), and systolic wall shear stress (0.85±0.28 versus 0.59±0.17 N/m 2 ; P <0.001) compared with healthy volunteers. BAV with right-handed flow and right-non coronary cusp fusion (n=31) showed more severe flow abnormalities (rotational flow, 38.5±16.5 versus 27.8±12.4 mm 2 /s; P <0.001; systolic flow angle, 29.4°±10.9° versus 19.4°±11.4°; P <0.001; in-plane wall shear stress, 0.64±0.23 versus 0.47±0.22 N/m 2 ; P <0.001) and larger aortas (19.5±3.4 versus 17.5±3.1 mm/m 2 ; P <0.05) than right–left cusp fusion (n=55). Patients with BAV with normal flow patterns had similar aortic dimensions and wall shear stress to healthy volunteers and younger patients with BAV showed abnormal flow patterns but no aortic dilation, both further supporting the importance of flow pattern in the pathogenesis of aortic dilation. Aortic function measures (distensibility, aortic strain, and pulse wave velocity) were similar across all groups. Conclusions—: Flow abnormalities may be a major contributor to aortic dilation in BAV. Fusion type affects the severity of flow abnormalities and may allow better risk prediction and selection of patients for earlier surgical intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Haycock, G. B., Schwartz, G. J., & Wisotsky, D. H. (1978) · The Journal of Pediatrics · doi:10.1016/s0022-3476(78)80601-5 · Cited by 1,675
A classification system for the bicuspid aortic valve from 304 surgical specimens
Sievers, H.-H., & Schmidtke, C. (2007) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.01.039 · Cited by 1,222
Clinical significance of the bicuspid aortic valve
Ward, C. (2000) · Heart · doi:10.1136/heart.83.1.81 · Cited by 803
Michelena, H. I., Desjardins, V. A., Avierinos, J.-F., Russo, A., Nkomo, V. T., Sundt, T. M., Pellikka, P. A., Tajik, A. J., & Enriquez-Sarano, M. (2008) · Circulation · doi:10.1161/circulationaha.107.740878 · Cited by 609
Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21778 · Cited by 474
Self-citationBicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending Aorta
Barker, A. J., Markl, M., Bürk, J., Lorenz, R., Bock, J., Bauer, S., Schulz-Menger, J., & von Knobelsdorff-Brenkenhoff, F. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.973370 · Cited by 454
Self-citationBicuspid Aortic Valve: Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns
Hope, M. D., Hope, T. A., Meadows, A. K., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2010) · Radiology · doi:10.1148/radiol.09091437 · Cited by 417
Cellular mechanics and gene expression in blood vessels
Lehoux, S., & Tedgui, A. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00441-4 · Cited by 333
4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease
Hope, M. D., Hope, T. A., Crook, S. E. S., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.05.004 · Cited by 273
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Self-citationMichelena, H. I., Prakash, S. K., Della Corte, A., Bissell, M. M., Anavekar, N., Mathieu, P., Bossé, Y., Limongelli, G., Bossone, E., Benson, D. W., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.007851 · Cited by 442
Self-citationMahadevia, R., Barker, A. J., Schnell, S., Entezari, P., Kansal, P., Fedak, P. W. M., Malaisrie, S. C., McCarthy, P., Collins, J., Carr, J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.003026 · Cited by 413
Self-citationEACTS/STS Guidelines for diagnosing and treating acute and chronic syndromes of the aortic organ
Czerny, M., Grabenwöger, M., Berger, T., Aboyans, V., Della Corte, A., Chen, E. P., Desai, N. D., Dumfarth, J., Elefteriades, J. A., Etz, C. D., et al. (2024) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezad426 · Cited by 412
EACTS/STS Guidelines for Diagnosing and Treating Acute and Chronic Syndromes of the Aortic Organ
Czerny, M., Grabenwöger, M., Berger, T., Aboyans, V., Della Corte, A., Chen, E. P., Desai, N. D., Dumfarth, J., Elefteriades, J. A., Etz, C. D., et al. (2024) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2024.01.021 · Cited by 331
Metadata
- Authors
- Bissell, M. M., Hess, A. T., Biasiolli, L., Glaze, S. J., Loudon, M., Pitcher, A., Davis, A., Prendergast, B., Markl, M., Barker, A. J., Neubauer, S., & Myerson, S. G.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2013-07
- Volume
- 6
- Issue
- 4
- Pages
- 499-507
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2149678147
- Cited by
- 380
- References
- 26
- FWCI
- 23.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aortic Dilation in Bicuspid Aortic Valve Disease: Flow Pattern Is a Major Contributor and Differs With Valve Fusion Type. https://app.cochat.ai/papers/10.1161/circimaging.113.000528
- The paper
- Bissell, M. M., Hess, A. T., Biasiolli, L., Glaze, S. J., Loudon, M., Pitcher, A., Davis, A., Prendergast, B., Markl, M., Barker, A. J., Neubauer, S., & Myerson, S. G. (2013). Aortic Dilation in Bicuspid Aortic Valve Disease: Flow Pattern Is a Major Contributor and Differs With Valve Fusion Type. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.113.000528
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.