Melody Valve Implant Within Failed Bioprosthetic Valves in the Pulmonary Position: A Multicenter Experience
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background—: Transcatheter pulmonary valve implantation using the Melody valve has emerged as an important therapy for the treatment of postoperative right ventricular outflow tract dysfunction. Melody-in-bioprosthetic valves (BPV) is currently considered an off-label indication. We review the combined experience with transcatheter pulmonary valve implantation within BPVs from 8 centers in the United States and discuss technical aspects of the Melody-in-BPV procedure. Methods and Results—: A total of 104 patients underwent Melody-in-BPV in the pulmonary position at 8 US centers from April 2007 to January 2012. Ten different types of BPVs were intervened on, with Melody valve implantation at the intended site in all patients. Following Melody valve implant, the peak right ventricle-to-pulmonary artery gradient decreased from 38.7±16.3 to 10.9±6.7 mm Hg ( P <0.001), and the right ventricular systolic pressure fell from 71.6±21.7 to 46.7±15.9 mm Hg ( P <0.001). There was no serious procedural morbidity, and no deaths related to the catheterization or implant. At a median follow-up of 12 months (1–46 months), no patients had more than mild regurgitation, and 4 had a mean right ventricular outflow tract gradient ≥30 mm Hg. During follow-up, there were 2 stent fractures, 3 cases of endocarditis (2 managed with surgical explant), and 2 deaths that were unrelated to the Melody valve. Conclusions—: Transcatheter pulmonary valve implantation using the Melody valve within BPVs can be accomplished with a high rate of success, low procedure-related morbidity and mortality, and excellent short-term results. The findings of this preliminary multicenter experience suggest that the Melody valve is an effective transcatheter treatment option for failed BPVs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonhoeffer, P., Boudjemline, Y., Saliba, Z., Merckx, J., Aggoun, Y., Bonnet, D., Acar, P., Le Bidois, J., Sidi, D., & Kachaner, J. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02844-0 · Cited by 1,095
Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair
Therrien, J., Provost, Y., Merchant, N., Williams, W., Colman, J., & Webb, G. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.11.037 · Cited by 664
McElhinney, D. B., Hellenbrand, W. E., Zahn, E. M., Jones, T. K., Cheatham, J. P., Lock, J. E., & Vincent, J. A. (2010) · Circulation · doi:10.1161/circulationaha.109.921692 · Cited by 577
Self-citationTherrien, J., Siu, S. C., McLaughlin, P. R., Liu, P. P., Williams, W. G., & Webb, G. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00930-x · Cited by 543
Transcatheter Valve-in-Valve Implantation for Failed Bioprosthetic Heart Valves
Webb, J. G., Wood, D. A., Ye, J., Gurvitch, R., Masson, J.-B., Rodés-Cabau, J., Osten, M., Horlick, E., Wendler, O., Dumont, E., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.924613 · Cited by 508
Lurz, P., Coats, L., Khambadkone, S., Nordmeyer, J., Boudjemline, Y., Schievano, S., Muthurangu, V., Lee, T. Y., Parenzan, G., Derrick, G., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.735779 · Cited by 481 · cited 1×
“5% to 23%.(4,5,20) The fact that radiographic follow-up was not standardized limits our ability to conclusively assess the overall freedom from stent fracture after Melody valve-in-BPV implant.”
BackgroundPercutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients
Khambadkone, S., Coats, L., Taylor, A., Boudjemline, Y., Derrick, G., Tsang, V., Cooper, J., Muthurangu, V., Hegde, S. R., Razavi, R. S., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.523266 · Cited by 459
Zahn, E. M., Hellenbrand, W. E., Lock, J. E., & McElhinney, D. B. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.034 · Cited by 322
Self-citationPercutaneous pulmonary valve implantation: two-centre experience with more than 100 patients
Eicken, A., Ewert, P., Hager, A., Peters, B., Fratz, S., Kuehne, T., Busch, R., Hess, J., & Berger, F. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq520 · Cited by 296 · cited 1×
“5% to 23%.(4,5,20) The fact that radiographic follow-up was not standardized limits our ability to conclusively assess the overall freedom from stent fracture after Melody valve-in-BPV implant.”
BackgroundIndications and Timing of Pulmonary Valve Replacement After Tetralogy of Fallot Repair
Geva, T. (2006) · Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual · doi:10.1053/j.pcsu.2006.02.009 · Cited by 275
McElhinney, D. B., Cheatham, J. P., Jones, T. K., Lock, J. E., Vincent, J. A., Zahn, E. M., & Hellenbrand, W. E. (2011) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.111.965616 · Cited by 246
Self-citationNordmeyer, J., Khambadkone, S., Coats, L., Schievano, S., Lurz, P., Parenzan, G., Taylor, A. M., Lock, J. E., & Bonhoeffer, P. (2007) · Circulation · doi:10.1161/circulationaha.106.674259 · Cited by 214 · cited 1×
“One of the most significant concerns with the Melody valve implanted into RVOT conduits has been stent fracture.(21) In this series, during a median follow-up of 12 months, only 2 stent fractures were diagnosed, both of which were discovered 13 months after implant.”
BackgroundExtended Application of Percutaneous Pulmonary Valve Implantation
Momenah, T. S., Oakley, R. M. E., Najashi, K. S. A., Khoshhal, S., Qethamy, H. O. A., & Bonhoeffer, P. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.061 · Cited by 142
Transcatheter Aortic Valve Implantation for Failing Surgical Aortic Bioprosthetic Valve
Piazza, N., Bleiziffer, S., Brockmann, G., Hendrick, R., Deutsch, M.-A., Opitz, A., Mazzitelli, D., Tassani‐Prell, P., Schreiber, C., & Lange, R. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.03.016 · Cited by 133 · cited 2×
“Mosaic).(14) The stated nominal width of each device refers to the diameter of the outermost dimension at the base of the device, with the inner diameter (ID) generally 2 mm smaller.”
BackgroundTranscatheter Aortic Valve Implantation for Failing Surgical Aortic Bioprosthetic Valve
Piazza, N., Bleiziffer, S., Brockmann, G., Hendrick, R., Deutsch, M.-A., Opitz, A., Mazzitelli, D., Tassani‐Prell, P., Schreiber, C., & Lange, R. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.05.007 · Cited by 128
Seiffert, M., Franzen, O. W., Conradi, L., Baldus, S. E., Schirmer, J. M., Meinertz, T., Reichenspurner, H. C., & Treede, H. (2010) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22618 · Cited by 110
Transcatheter Aortic Valve Implantation for Stenosed and Regurgitant Aortic Valve Bioprostheses
Khawaja, M. Z., Haworth, P., Ghuran, A., Lee, L. S., de Belder, A., Hutchinson, N., Trivedi, U., Laborde, J., & Hildick‐Smith, D. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.060 · Cited by 95
Cited by
Heart Disease and Stroke Statistics—2020 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Delling, F. N., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000757 · Cited by 9,175
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart disease and stroke statistics-2018 update: a report from the american heart association
Benjamin, E. J., Virani, S. S., Callaway, C. W., Chamberlain, A. M., Chang, A. R., Cheng, S., Chiuve, S. E., Cushman, M., Delling, F. N., Deo, R., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000558 · Cited by 7,146
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Metadata
- Authors
- Gillespie, M. J., Rome, J. J., Levi, D. S., Williams, R. J., Rhodes, J. F., Cheatham, J. P., Hellenbrand, W. E., Jones, T. K., Vincent, J. A., Zahn, E. M., & McElhinney, D. B.
- Venue
- Circulation: Cardiovascular Interventions
- Published
- 2012-12
- Volume
- 5
- Issue
- 6
- Pages
- 862-870
- ISSN
- 1941-7632 (ISSN-L)
- 1941-7640
- OpenAlex
- W1976881664
- Cited by
- 164
- References
- 17
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.