Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 190

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial

Open access
Søndergaard, Lars, Steinbrüchel, Daniel Andreas, Ihlemann, Nikolaj, Nissen, Henrik, Kjeldsen, Bo Juel, Petursson, Petur, Ngo, Anh Thuc, Olsen, Niels Thue, Chang, Yanping, Franzen, Olaf Walter, Engstrøm, Thomas, Clemmensen, Peter, Olsen, Peter Skov, Thyregod, Hans Gustav Hørsted · 2016 · Circulation: Cardiovascular Interventions

Abstract

Background—: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), including a lower-risk patient population than previous trials. This article reports 2-year clinical and echocardiographic outcomes from the NOTION trial. Methods and Results—: Two-hundred eighty patients from 3 centers in Denmark and Sweden were randomized to either TAVR (n=145) or SAVR (n=135) with follow-up planned for 5 years. There was no difference in all-cause mortality at 2 years between TAVR and SAVR (8.0% versus 9.8%, respectively; P =0.54) or cardiovascular mortality (6.5% versus 9.1%; P =0.40). The composite outcome of all-cause mortality, stroke, or myocardial infarction was also similar (15.8% versus 18.8%, P =0.43). Forward-flow hemodynamics were improved following both procedures, with effective orifice area significantly more improved after TAVR than SAVR (effective orifice area, 1.7 versus 1.4 cm 2 at 3 months). Mean valve gradients were similar after TAVR and SAVR. When patients were categorized according to Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) (<4% versus ≥4%), there was no statistically significant difference for TAVR and SAVR groups in the composite outcome for low-risk (14.7%, 95% confidence interval, 8.3–21.2 versus 16.8%; 95% confidence interval, 9.7–23.8; P =0.58) or intermediate-risk patients (21.1% versus 27.1%; P =0.59). Conclusions—: Two-year results from the NOTION trial demonstrate the continuing safety and effectiveness of TAVR in lower-risk patients. Longer-term data are needed to verify the durability of this procedure in this patient population. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01057173.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.115.003665

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Søndergaard, L., Steinbrüchel, D. A., Ihlemann, N., Nissen, H., Kjeldsen, B. J., Petursson, P., Ngo, A. T., Olsen, N. T., Chang, Y., Franzen, O. W., Engstrøm, T., Clemmensen, P., Olsen, P. S., & Thyregod, H. G. H.
Venue
Circulation: Cardiovascular Interventions
Published
2016-06
Volume
9
Issue
6
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W2547280979
Cited by
190
References
7
FWCI
26.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.