Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Tissue Engineering of Heart Valves: Decellularized Porcine and Human Valve Scaffolds Differ Importantly in Residual Potential to Attract Monocytic Cells

Rieder, Erwin, Seebacher, Gernot, Kasimir, Marie-Theres, Eichmair, Eva, Winter, Birgitta, Dekan, Barbara, Wolner, Ernst, Simon, Paul, Weigel, Guenter·2005·Circulation

Abstract

Background— Tissue-engineered or decellularized heart valves have already been implanted in humans or are currently approaching the clinical setting. The aim of this study was to examine the migratory response of human monocytic cells toward decellularized porcine and human heart valves, a pivotal step in the early immunologic reaction. Methods and Results— Porcine and human pulmonary valve conduits were decellularized, and migration of U-937 monocytic cells toward extracted heart valve proteins was examined in a transmigration chamber in vitro. Homogenized tissue specimens were size fractionated by SDS-PAGE. The decellularization procedure effectively reduced the migration of human monocytes toward all heart valve tissue. However, only the antigen reduction of human pulmonary valves abolished the monocytic response (wall, 0.88±0.19% versus 30.20±3.93% migrated cells [mean±SEM]; cusps, 0.10±0.06% versus 10.24±1.83%) and was significantly lower ( P <0.05) than that of the decellularized porcine equivalent (wall, 5.03±0.14% versus 24.31±2.38%; cusps, 3.18±0.38% versus 10.24±1.83%). SDS-PAGE of the pulmonary heart valve tissue revealed that considerable amounts of proteins with different molecular weights that were not detected in the human equivalent remain in the decellularized porcine heart valve. Conclusions— We describe for the first time that the remaining potential of decellularized pulmonary heart valves to attract monocytic cells depends strongly on whether porcine or human scaffolds were used. These findings will have an important impact on further investigations in the field of heart valve tissue engineering.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.473629

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 171

Metadata

Authors
Rieder, E., Seebacher, G., Kasimir, M.-T., Eichmair, E., Winter, B., Dekan, B., Wolner, E., Simon, P., & Weigel, G.
Venue
Circulation
Published
2005-05-31
Volume
111
Issue
21
Pages
2792-2797
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2052914625
Cited by
171
References
1
FWCI
10.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tissue Engineering of Heart Valves: Decellularized Porcine and Human Valve Scaffolds Differ Importantly in Residual Potential to Attract Monocytic Cells. https://app.cochat.ai/papers/10.1161/circulationaha.104.473629
The paper
Rieder, E., Seebacher, G., Kasimir, M.-T., Eichmair, E., Winter, B., Dekan, B., Wolner, E., Simon, P., & Weigel, G. (2005). Tissue Engineering of Heart Valves: Decellularized Porcine and Human Valve Scaffolds Differ Importantly in Residual Potential to Attract Monocytic Cells. Circulation. https://doi.org/10.1161/circulationaha.104.473629

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.