Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 543

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Real-Time Three-Dimensional Echocardiography: A Novel Technique to Quantify Global Left Ventricular Mechanical Dyssynchrony

Open access
Kapetanakis, S., Kearney, M.T., Siva, A., Gall, N., Cooklin, M., Monaghan, M.J.·2005·Circulation

Abstract

Background— Left ventricular (LV) mechanical dyssynchrony (LVMD) has emerged as a therapeutic target using cardiac resynchronization therapy (CRT) in selected patients with chronic heart failure. Current methods used to evaluate LVMD are technically difficult and do not assess LVMD of the whole LV simultaneously. We developed and validated real-time 3D echocardiography (RT3DE) as a novel method to assess global LVMD. Methods and Results— Eighty-nine healthy volunteers and 174 unselected patients referred for routine echocardiography underwent 2D echocardiography and RT3DE. RT3DE data sets provided time-volume analysis for global and segmental LV volumes. A systolic dyssynchrony index (SDI) was derived from the dispersion of time to minimum regional volume for all 16 LV segments. Healthy subjects and patients with normal LV systolic function had highly synchronized segmental function (SDI, 3.5±1.8% and 4.5±2.4%; P =0.7). SDI increased with worsening LV systolic function regardless of QRS duration (mild, 5.4±0.83%; moderate, 10.0±2%; severe LV dysfunction, 15.6±1%; P for trend <0.001). We found that 37% of patients with moderate to severe LV systolic dysfunction had significant dyssynchrony with normal QRS durations (SDI, 14.7±1.2%). Twenty-six patients underwent CRT. At long-term follow-up, responders demonstrated reverse remodeling after CRT with a significant reduction in SDI (16.9±1.1% to 6.9±1%; P <0.0001) and end-diastolic volume (196.6±17.3 to 132.1±13.5 mL; P <0.0001) associated with an increase in LV ejection fraction (17±2.2% to 31.6±2.9%; P <0.0001). Conclusions— RT3DE can quantify global LVMD in patients with and without QRS prolongation. RT3DE represents a novel technique to identify chronic heart failure patients who may otherwise not be considered for CRT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.474445

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 543

Metadata

Authors
Kapetanakis, S., Kearney, M. T., Siva, A., Gall, N., Cooklin, M., & Monaghan, M. J.
Venue
Circulation
Published
2005-08-16
Volume
112
Issue
7
Pages
992-1000
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2033574971
Cited by
543
References
25
FWCI
32.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-Time Three-Dimensional Echocardiography: A Novel Technique to Quantify Global Left Ventricular Mechanical Dyssynchrony. https://app.cochat.ai/papers/10.1161/circulationaha.104.474445
The paper
Kapetanakis, S., Kearney, M. T., Siva, A., Gall, N., Cooklin, M., & Monaghan, M. J. (2005). Real-Time Three-Dimensional Echocardiography: A Novel Technique to Quantify Global Left Ventricular Mechanical Dyssynchrony. Circulation. https://doi.org/10.1161/circulationaha.104.474445

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.