The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Intrathoracic Impedance Monitoring in Patients With Heart Failure: Correlation With Fluid Status and Feasibility of Early Warning Preceding Hospitalization
Open accessAbstract
Background— Patients with heart failure are frequently hospitalized for fluid overload. A reliable method for chronic monitoring of fluid status is therefore desirable. We evaluated an implantable system capable of measuring intrathoracic impedance to identify potential fluid overload before heart failure hospitalization and to determine the correlation between intrathoracic impedance and standard measures of fluid status during hospitalization. Methods and Results— Thirty-three patients with NYHA class III and IV heart failure were implanted with a special pacemaker in the left pectoral region and a defibrillation lead in the right ventricle. Intrathoracic impedance was regularly measured and recorded between the lead and the pacemaker case. During hospitalizations, pulmonary capillary wedge pressure and fluid status were monitored. Ten patients were hospitalized for fluid overload 25 times over 20.7±8.4 months. Intrathoracic impedance decreased before each admission by an average of 12.3±5.3% ( P <0.001) over an average of 18.3±10.1 days. Impedance reduction began 15.3±10.6 days ( P <0.001) before the onset of worsening symptoms. There was an inverse correlation between intrathoracic impedance and pulmonary capillary wedge pressure ( r =−0.61, P <0.001) and between intrathoracic impedance and net fluid loss ( r =−0.70, P <0.001) during hospitalization. Automated detection of impedance decreases was 76.9% sensitive in detecting hospitalization for fluid overload, with 1.5 false-positive (threshold crossing without hospitalization) detections per patient-year of follow-up. Conclusions— Intrathoracic impedance is inversely correlated with pulmonary capillary wedge pressure and fluid balance and decreased before the onset of patient symptoms and before hospital admission for fluid overload. Regular monitoring of impedance may provide early warning of impending decompensation and diagnostic information for titration of medication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
Young, J. B., Abraham, W. T., & Smith, A. L. (2003) · ACC Current Journal Review · doi:10.1016/j.accreview.2003.08.087 · Cited by 1,682
Committee Members, Hunt, S. A., Baker, D. W., Chin, M. H., Cinquegrani, M. P., Feldmanmd, A. M., Francis, G. S., Ganiats, T. G., Goldstein, S., Gregoratos, G., et al. (2001) · Circulation · doi:10.1161/hc4901.102568 · Cited by 1,442
The Current Cost of Heart Failure to the National Health Service in the UK
Stewart, S., Jenkins, A., Buchan, S., McGuire, A., Capewell, S., & McMurray, J. J. J. V. (2002) · European Journal of Heart Failure · doi:10.1016/s1388-9842(01)00198-2 · Cited by 582
Electrical properties of the epidermal stratum corneum
Yamamoto, T., & Yamamoto, Y. (1976) · Medical & Biological Engineering · doi:10.1007/bf02478741 · Cited by 436
The Minnesota impedance cardiograph- theory and applications.
Kubicek, W. G., Kottke, J., Ramos, M. U., PATTERSON, R. P., Witsoe, D. A., LaBree, J. W., Remole, W., Layman, T. E., Schoening, H., & Garamela, J. T. (1974) · PubMed · Cited by 396
Goldberg, L. R., Piette, J. D., Walsh, M. N., Frank, T. A., Jaski, B. E., Smith, A. L., Rodriguez, R., Mancini, D. M., Hopton, L. A., Orav, E. J., et al. (2003) · American Heart Journal · doi:10.1016/s0002-8703(03)00393-4 · Cited by 366
Adamson, P. B., Smith, A. L., Abraham, W. T., Kleckner, K. J., Stadler, R. W., Shih, A., & Rhodes, M. M. (2004) · Circulation · doi:10.1161/01.cir.0000139841.42454.78 · Cited by 309
Self-citationHunt, S. A., Baker, D. W., Chin, M. H., Cinquegrani, M. P., Feldman, A. M., Francis, G. S., Ganiats, T. G., Goldstein, S., Gregoratos, G., Jessup, M. L., et al. (2002) · The Journal of Heart and Lung Transplantation · doi:10.1016/s1053-2498(01)00776-8 · Cited by 285
A Systematic Review of Telemonitoring for the Management of Heart Failure
Louis, A. A., Turner, T., Gretton, M., Baksh, A., & Cleland, J. G. F. (2003) · European Journal of Heart Failure · doi:10.1016/s1388-9842(03)00160-0 · Cited by 255
Characterization of the precipitants of hospitalization for heart failure decompensation
Bennett, S., Huster, G., Baker, S., Milgrom, L., Kirchgassner, A., Birt, J., & Pressler, M. (1998) · American Journal of Critical Care · doi:10.4037/ajcc1998.7.3.168 · Cited by 240
Older adults' symptoms and their duration before hospitalization for heart failure
Friedman, M. M. (1997) · Heart & Lung · doi:10.1016/s0147-9563(97)90053-4 · Cited by 198
Luepker, R. V., Michael, J. R., & Warbasse, J. R. (1973) · American Heart Journal · doi:10.1016/0002-8703(73)90529-2 · Cited by 125
Monitoring the Chest with Impedance
Water, J. M. V. D., Mount, B. E., Barela, J. R., Schuster, R., & Leacock, F. S. (1973) · CHEST Journal · doi:10.1378/chest.64.5.597 · Cited by 103
Wang, L., LAHTINEN, S. P., Lentz, L. R., Rakow, N., Kaszas, C. J., Ruetz, L. L., Stylos, L., & Olson, W. H. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.40009.x · Cited by 83
Self-citationCharacteristics of skin admittance for dry electrodes and the measurement of skin moisturisation
Yamamoto, Y., & Yamamoto, T. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441608 · Cited by 77
The electrical impedance of the human thorax as a guide in evaluation of intrathoracic fluid volume
Sahalos, J. N., Nicolaidis, A., & Gotsis, N. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/4/008 · Cited by 28
Noninvasive Measurement of Intrathoracic Fluids
Baker, L. E., & Denniston, J. C. (1974) · CHEST Journal · doi:10.1378/chest.65.4_supplement.35s · Cited by 27
Cited by
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Gheorghiade, M., Follath, F., Ponikowski, P., Barsuk, J. H., Blair, J. E. A., Cleland, J. G., Dickstein, K., Drazner, M. H., Fonarow, G. C., Jaarsma, T., et al. (2010) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfq045 · Cited by 739
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
Zile, M. R., Bennett, T. D., St. John Sutton, M., Cho, Y. K., Adamson, P. B., Aaron, M. F., Aranda, J. M., Abraham, W. T., Smart, F. W., Stevenson, L. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.783910 · Cited by 571
van Veldhuisen, D. J., Braunschweig, F., Conraads, V., Ford, I., Cowie, M. R., Jondeau, G., Kautzner, J., Muñoz Aguilera, R., Lunati, M., Yu, C. M., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.043042 · Cited by 444
Self-citation
Metadata
- Authors
- Yu, C.-M., Wang, L., Chau, E., Chan, R. H.-W., Kong, S.-L., Tang, M.-O., Christensen, J., Stadler, R. W., & Lau, C.-P.
- Venue
- Circulation
- Published
- 2005-08-09
- Volume
- 112
- Issue
- 6
- Pages
- 841-848
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2166379766
- Cited by
- 711
- References
- 21
- FWCI
- 25.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.