Interruptions of Chest Compressions During Emergency Medical Systems Resuscitation
Abstract
Background— Survival after nontraumatic out-of-hospital (OOH) cardiac arrest in Tucson, Arizona, has been flat at 6% (121/2177) for the decade 1992 to 2001. We hypothesized that interruptions of chest compressions occur commonly and for substantial periods during treatment of OOH cardiac arrest and could be contributing to the lack of improvement in resuscitation outcome. Methods and Results— Sixty-one adult OOH cardiac arrest patients treated by automated external defibrillator (AED)–equipped Tucson Fire Department first responders from November 2001 through November 2002 were retrospectively reviewed. Reviews were performed according to the code arrest record and verified with the AED printout. Validation of the methodology for determining the performance of chest compressions was done post hoc. The median time from “9-1-1” call receipt to arrival at the patient’s side was 6 minutes, 27 seconds (interquartile range [IQR, 25% to 75%], 5 minutes, 24 seconds, to 7 minutes, 34 seconds). An additional 54 seconds (IQR, 38 to 74 seconds) was noted between arrival and the first defibrillation attempt. Initial defibrillation shocks never restored a perfusing rhythm (0/21). Chest compressions were performed only 43% of the time during the resuscitation effort. Although attempting to follow the 2000 guidelines for cardiopulmonary resuscitation, chest compressions were delayed or interrupted repeatedly throughout the resuscitation effort. Survival to hospital discharge was 7%, not different from that of our historical control (4/61 versus 121/2177; P =0.74). Conclusions— Frequent interruption of chest compressions results in no circulatory support during more than half of resuscitation efforts. Such interruptions could be a major contributing factor to the continued poor outcome seen with OOH cardiac arrest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cummins, R. O., Chamberlain, D. A., Abramson, N. S., Allen, M., Baskett, P. J., Becker, L., Bossaert, L., Delooz, H. H., Dick, W. F., & Eisenberg, M. S. (1991) · Circulation · doi:10.1161/01.cir.84.2.960 · Cited by 1,670
Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest
Wik, L. (2005) · JAMA · doi:10.1001/jama.293.3.299 · Cited by 1,538
Outcomes of Rapid Defibrillation by Security Officers after Cardiac Arrest in Casinos
Valenzuela, T. D., Roe, D. J., Nichol, G., Clark, L. L., Spaite, D. W., & Hardman, R. G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010263431701 · Cited by 1,485
Self-citationQuality of Cardiopulmonary Resuscitation During In-Hospital Cardiac Arrest
Abella, B. S. (2005) · JAMA · doi:10.1001/jama.293.3.305 · Cited by 1,185
Public-Access Defibrillation and Survival after Out-of-Hospital Cardiac Arrest
(2004) · New England Journal of Medicine · doi:10.1056/nejmoa040566 · Cited by 1,130
Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest
Abella, B. S., Alvarado, J. P., & Myklebust, H. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.03.040 · Cited by 941
Chamberlain, D., Cummins, R. O., Abramson, N., Allen, M., Baskett, P., Becker, L., Bossaert, L., Delooz, H., Dick, W., Eisenberg, M., et al. (1991) · Resuscitation · doi:10.1016/0300-9572(91)90061-3 · Cited by 914
Estimating Effectiveness of Cardiac Arrest Interventions: A Logistic Regression Survival Model
Valenzuela, T. D., Roe, D. J., Cretin, S., Spaite, D. W., & Larsen, M. P. (1997) · Circulation · doi:10.1161/01.cir.96.10.3308 · Cited by 839
Self-citationAdvanced Cardiac Life Support in Out-of-Hospital Cardiac Arrest
Stiell, I. G., Wells, G. A., Field, B., Spaite, D. W., Nesbitt, L. P., De Maio, V. J., Nichol, G., Cousineau, D., Blackburn, J., Munkley, D., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040325 · Cited by 835
Public Use of Automated External Defibrillators
Caffrey, S. L., Willoughby, P. J., Pepe, P. E., & Becker, L. B. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa020932 · Cited by 800
Cobb, L. A. (1999) · JAMA · doi:10.1001/jama.281.13.1182 · Cited by 730
Guidelines, C. A. R. F. T. N. R. (2000) · Pediatrics · doi:10.1542/peds.106.3.e29 · Cited by 720
Berg, R. A., Sanders, A. B., Kern, K. B., Hilwig, R. W., Heidenreich, J. W., Porter, M. E., & Ewy, G. A. (2001) · Circulation · doi:10.1161/hc4501.098926 · Cited by 715
Self-citationChanging Incidence of Out-of-Hospital Ventricular Fibrillation, 1980-2000
Cobb, L. A. (2002) · JAMA · doi:10.1001/jama.288.23.3008 · Cited by 678
Wik, L., Hansen, T. B., Fylling, F., Steen, T., Vaagenes, P., Auestad, B. H., & Steen, P. A. (2003) · JAMA · doi:10.1001/jama.289.11.1389 · Cited by 646
Resuscitation After Cardiac Arrest: A 3-Phase Time-Sensitive Model
Weisfeldt, M. L., & Becker, L. B. (2002) · JAMA · doi:10.1001/jama.288.23.3035 · Cited by 637
Use of Automated External Defibrillators by a U.S. Airline
Page, R. L., Joglar, J. A., Kowal, R. C., Zagrodzky, J. D., Nelson, L. L., Ramaswamy, K., Barbera, S. J., Hamdan, M. H., & McKenas, D. K. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010263431702 · Cited by 632
Kern, K. B., Hilwig, R. W., Berg, R. A., Sanders, A. B., & Ewy, G. A. (2002) · Circulation · doi:10.1161/hc0502.102963 · Cited by 516
Self-citationAdverse Outcomes of Interrupted Precordial Compression During Automated Defibrillation
Yu, T., Weil, M. H., Tang, W., Sun, S., Klouche, K., Povoas, H., & Bisera, J. (2002) · Circulation · doi:10.1161/01.cir.0000021429.22005.2e · Cited by 448
Standards and Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiac Care (ECC)
(1980) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1980.03310050017015 · Cited by 325
Berg, R. A., Hilwig, R. W., Kern, K. B., & Ewy, G. A. (2000) · Circulation · doi:10.1161/01.cir.101.14.1743 · Cited by 212
Self-citationvan Alem, A. P., Chapman, F. W., Lank, P., Hart, A. A. M., & Koster, R. W. (2003) · Resuscitation · doi:10.1016/s0300-9572(03)00106-0 · Cited by 195
Berg, R. A., Hilwig, R. W., Kern, K. B., Babar, I., & Ewy, G. A. (1999) · Critical Care Medicine · doi:10.1097/00003246-199909000-00030 · Cited by 166
Self-citationBerg, R. A., Chapman, F. W., Berg, M., Hilwig, R. W., Banville, I. L., Walker, R. G., Nova, R. C., Sherrill, D. L., & Kern, K. B. (2004) · Resuscitation · doi:10.1016/j.resuscitation.2003.12.021 · Cited by 92
Self-citation
Cited by
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
Self-citationMeaney, P. A., Bobrow, B. J., Mancini, M. E., Christenson, J., de Caen, A. R., Bhanji, F., Abella, B. S., Kleinman, M. E., Edelson, D. P., Berg, R. A., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829d8654 · Cited by 1,072
Self-citationEuropean Resuscitation Council Guidelines for Resuscitation 2005
Soar, J., Deakin, C. D., Nolan, J. P., Abbas, G., Alfonzo, A., Handley, A. J., Lockey, D., Perkins, G. D., & Thies, K. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.10.004 · Cited by 832
Christenson, J., Andrusiek, D., Everson-Stewart, S., Kudenchuk, P., Hostler, D., Powell, J., Callaway, C. W., Bishop, D., Vaillancourt, C., Davis, D., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.852202 · Cited by 759
Self-citationBerg, R. A., Hemphill, R., Abella, B. S., Aufderheide, T. P., Cave, D. M., Hazinski, M. F., Lerner, E. B., Rea, T. D., Sayre, M. R., & Swor, R. A. (2010) · Circulation · doi:10.1161/circulationaha.110.970939 · Cited by 713
Self-citation
Metadata
- Authors
- Valenzuela, T. D., Kern, K. B., Clark, L. L., Berg, R. A., Berg, M. D., Berg, D. D., Hilwig, R. W., Otto, C. W., Newburn, D., & Ewy, G. A.
- Venue
- Circulation
- Published
- 2005-08-30
- Volume
- 112
- Issue
- 9
- Pages
- 1259-1265
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2162770324
- Cited by
- 316
- References
- 24
- FWCI
- 25.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.