The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Adverse Outcomes of Interrupted Precordial Compression During Automated Defibrillation
Abstract
Background — Current versions of automated external defibrillators (AEDs) require frequent stopping of chest compression for rhythm analyses and capacity charging. The present study was undertaken to evaluate the effects of these interruptions during the operation of AEDs. Methods and Results — Ventricular fibrillation was electrically induced in 20 male domestic swine weighing between 37.5 and 43 kg that were untreated for 7 minutes before CPR was started. Defibrillation was attempted with up to 3 sequential 150-J biphasic shocks, but each was preceded by 3-, 10-, 15-, or 20-second interruptions of chest compression. The interruptions corresponded to those that were mandated by commercially marketed AEDs for rhythm analyses and capacitor charge. The sequence of up to 3 electrical shocks and delays were repeated at 1-minute intervals until the animals were successfully resuscitated or for a total of 15 minutes. Spontaneous circulation was restored in each of 5 animals in which precordial compression was delayed for 3 seconds before the delivery of the first and subsequent shocks but in none of the animals in which the delay was >15 seconds before the delivery of the first and subsequent shocks. Longer intervals of CPR interventions were required, and there was correspondingly greater failure of resuscitation in close relationship to increasing delays. The durations of interruptions were inversely related to the durations of subthreshold levels of coronary perfusion pressure. Postresuscitation arterial pressure and left ventricular ejection fraction were more severely impaired with increasing delays. Conclusions — Interruptions of precordial compression for rhythm analyses that exceed 15 seconds before each shock compromise the outcome of CPR and increase the severity of postresuscitation myocardial dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kouwenhoven, W. B. (1960) · JAMA · doi:10.1001/jama.1960.03020280004002 · Cited by 2,106
Paradis, N. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03440080084029 · Cited by 1,061
Berg, R. A., Sanders, A. B., Kern, K. B., Hilwig, R. W., Heidenreich, J. W., Porter, M. E., & Ewy, G. A. (2001) · Circulation · doi:10.1161/hc4501.098926 · Cited by 715
Cardiopulmonary Resuscitation by Chest Compression Alone or with Mouth-to-Mouth Ventilation
Hallstrom, A., Cobb, L., Johnson, E., & Copass, M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005253422101 · Cited by 563
Kern, K. B., Hilwig, R. W., Berg, R. A., Sanders, A. B., & Ewy, G. A. (2002) · Circulation · doi:10.1161/hc0502.102963 · Cited by 516
Diuretic Therapy for Hypertension and the Risk of Primary Cardiac Arrest
Siscovick, D. S., Raghunathan, T. E., Psaty, B. M., Koepsell, T. D., Wicklund, K. G., Lin, X., Cobb, L., Rautaharju, P. M., Copass, M. K., & Wagner, E. H. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406303302603 · Cited by 434
Stiell, I. G., Wells, G. A., Field III, B. J., Spaite, D. W., De Maio, V. J., Ward, R., Munkley, D. P., Lyver, M. B., Luinstra, L. G., Campeau, T., et al. (1999) · JAMA · doi:10.1001/jama.281.13.1175 · Cited by 379
Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation.
Gudipati, C. V., Weil, M. H., Bisera, J., Deshmukh, H. G., & Rackow, E. C. (1988) · Circulation · doi:10.1161/01.cir.77.1.234 · Cited by 329
Self-citationNiemann, J. T., Cairns, C. B., Sharma, J., & Lewis, R. J. (1992) · Circulation · doi:10.1161/01.cir.85.1.281 · Cited by 209
Coronary perfusion pressure during cardiopulmonary resuscitation
Sanders, A. B., Ogle, M. E., & Ewy, G. A. (1985) · The American Journal of Emergency Medicine · doi:10.1016/0735-6757(85)90003-8 · Cited by 95
Cited by
Koster, R. W., Baubin, M. A., Bossaert, L. L., Caballero, A., Cassan, P., Castrén, M., Granja, C., Handley, A. J., Monsieurs, K. G., Perkins, G. D., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.009 · Cited by 1,556
Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest
Wik, L. (2005) · JAMA · doi:10.1001/jama.293.3.299 · Cited by 1,538
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
Quality of Cardiopulmonary Resuscitation During In-Hospital Cardiac Arrest
Abella, B. S. (2005) · JAMA · doi:10.1001/jama.293.3.305 · Cited by 1,185
Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest
Abella, B. S., Alvarado, J. P., & Myklebust, H. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.03.040 · Cited by 941
Metadata
- Authors
- Yu, T., Weil, M. H., Tang, W., Sun, S., Klouche, K., Povoas, H., & Bisera, J.
- Venue
- Circulation
- Published
- 2002-07-16
- Volume
- 106
- Issue
- 3
- Pages
- 368-372
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2009086644
- Cited by
- 448
- References
- 10
- FWCI
- 25.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adverse Outcomes of Interrupted Precordial Compression During Automated Defibrillation. https://app.cochat.ai/papers/10.1161/01.cir.0000021429.22005.2e
- The paper
- Yu, T., Weil, M. H., Tang, W., Sun, S., Klouche, K., Povoas, H., & Bisera, J. (2002). Adverse Outcomes of Interrupted Precordial Compression During Automated Defibrillation. Circulation. https://doi.org/10.1161/01.cir.0000021429.22005.2e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.