The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Open accessAbstract
Background— Percutaneous aortic valve implantation by an antegrade transvenous approach has been described but is problematic. Retrograde prosthetic aortic valve implantation via the femoral artery has potential advantages. Percutaneous prosthetic aortic valve implantation via the femoral arterial approach is described and the initial experience reported. Methods and Results— The valve prosthesis is constructed from a stainless steel stent with an attached trileaflet equine pericardial valve and a fabric cuff. After routine aortic balloon valvuloplasty, a 22F or 24F sheath is advanced from the femoral artery to the aorta. A steerable, deflectable catheter facilitates manipulation of the prosthesis around the aortic arch and through the stenotic valve. Rapid ventricular pacing is used to reduce cardiac output while the delivery balloon is inflated to deploy the prosthesis within the annulus. Percutaneous aortic prosthetic valve implantation was attempted in 18 patients (aged 81±6 years) in whom surgical risk was deemed excessive because of comorbidities. Iliac arterial injury, seen in the first 2 patients, did not recur after improvement in screening and access site management. Implantation was successful in 14 patients. After successful implantation, the aortic valve area increased from 0.6±0.2 to 1.6±0.4 cm 2 . There were no intraprocedural deaths. At follow-up of 75±55 days, 16 patients (89%) remained alive. Conclusions— This initial experience suggests that percutaneous transarterial aortic valve implantation is feasible in selected high-risk patients with satisfactory short-term outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
European system for cardiac operative risk evaluation (EuroSCORE)
Nashef, S. A. M., Roques, F., Michel, P., Gauducheau, E., Lemeshow, S., & Salamon, R. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00134-7 · Cited by 3,362
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Evaluation of aortic insufficiency by Doppler color flow mapping
Perry, G. J., Helmcke, F., Nanda, N. C., Byard, C., & Soto, B. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80254-1 · Cited by 882
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
ANDERSEN, H. R., KNUDSEN, L. L., & HASENKAM, J. M. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060238 · Cited by 491
Otto, C. M., Mickel, M. C., Kennedy, J. W., Alderman, E. L., Bashore, T. M., Block, P. C., Brinker, J. A., Diver, D., Ferguson, J., & Holmes, D. R. (1994) · Circulation · doi:10.1161/01.cir.89.2.642 · Cited by 476
Cardiac Catheterization, Angiography, and Intervention
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-115-8-664_3 · Cited by 423
Balloon aortic valvuloplasty in adults: Failure of procedure to improve long-term survival
Lieberman, E. B., Bashore, T. M., Hermiller, J. B., Wilson, J. S., Pieper, K. S., Keeler, G. P., Pierce, C. H., Kisslo, K. B., Harrison, J. K., & Davidson, C. J. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00363-0 · Cited by 299
Grossman & Baim's Cardiac Catheterization, Angiography, and Intervention
Baim, D. S., & Grossman, W. (2013) · Cited by 262
Bonow, R. O., Carabello, B., de Leon, A. C., Edmunds, L. H., Fedderly, B. J., Freed, M. D., Gaasch, W. H., McKay, C. R., Nishimura, R. A., O’Gara, P. T., et al. (2000) · Indian Journal of Thoracic and Cardiovascular Surgery · doi:10.1007/s12055-000-0010-9 · Cited by 246
Cardiac surgery in octogenarians. Peri-operative outcome and long-term results
Kolh, P. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2443 · Cited by 217
Quality of Life After Aortic Valve Replacement at the Age of >80 Years
Sundt, T. M., Bailey, M. S., Moon, M. R., Mendeloff, E. N., Huddleston, C. B., Pasque, M. K., Barner, H. B., & Gay, W. A. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-70 · Cited by 208
Quantification of aortic regurgitation utilizing continuous wave Doppler ultrasound
Teague, S. M., Heinsimer, J. A., Anderson, J. L., Sublett, K., Olson, E. G., Voyles, W. F., & Thadani, U. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80188-7 · Cited by 162
Percutaneous aortic valve replacement: An experimental study. I. Studies on implantation
Lutter, G., Kuklinski, D., Berg, G. A., von Samson, P., Martin, J., Handke, M., Uhrmeister, P., & Beyersdorf, F. (2002) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2002.121157 · Cited by 152
Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis
Cribier, A. G., Eltchaninoff, H., & Bash, A. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(03)00094-1 · Cited by 151
O’Neill, W. W., & The Mansfield Scientific Aortic Valvuloplasty Registry Investigators (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90727-q · Cited by 110
Aortic valve replacement in geriatric patients: determinants of in-hospital mortality
Bloomstein, L. Z., Gielchinsky, I., Bernstein, A. D., Parsonnet, V., Saunders, C. R., Karanam, R., & Graves, B. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)02326-2 · Cited by 94
Predictors of Event-Free Survival after Balloon Aortic Valvuloplasty
Kuntz, R. E., Tosteson, A. N. A., Berman, A. D., Goldman, L., Gordon, P. C., Leonard, B. M., McKay, R. G., Diver, D. J., & Safian, R. D. (1991) · New England Journal of Medicine · doi:10.1056/nejm199107043250104 · Cited by 85
Sakata, Y., Syed, Z., Salinger, M. H., & Feldman, T. E. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20300 · Cited by 83
Retrograde percutaneous aortic valve implantation for critical aortic stenosis
Hanzel, G. S., Harrity, P. J., SCHREIBER, T. L., & O’Neill, W. W. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20299 · Cited by 82
Vassiliades, T. A., Block, P. C., Cohn, L. H., Adams, D. H., BORER, J. S., Feldman, T. E., Holmes, D. R., Laskey, W. K., Lytle, B. W., Mack, M. J., et al. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20281 · Cited by 23
Quality of Life After Aortic Valve Replacement at the Age of >80 Years
Sundt, T. M., Bailey, M. S., Moon, M. R., Mendeloff, E. N., Huddleston, C. B., Pasque, M. K., Barner, H. B., & Gay, W. A. (2000) · Circulation · doi:10.1161/circ.102.suppl_3.iii-70 · Cited by 23
Aortenklappenersatz bei 80- und über 80-jährigen
Mortasawi, A., Gehle, S., Schröder, T., Ennker, I. C., Rosendahl, U., Dalladaku, F., Bauer, S., Albert, A., & Ennker, J. (2000) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s003910070017 · Cited by 14
Cited by
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationRecommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationWebb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Self-citation
Metadata
- Authors
- Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S.
- Venue
- Circulation
- Published
- 2006-02-14
- Volume
- 113
- Issue
- 6
- Pages
- 842-850
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2148154533
- Cited by
- 900
- References
- 23
- FWCI
- 55.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.