Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Cardiac Tissue Engineering in an In Vivo Vascularized Chamber

Morritt, Andrew N., Bortolotto, Susan K., Dilley, Rodney J., Han, XiaoLian, Kompa, Andrew R., McCombe, David, Wright, Christine E., Itescu, Silviu, Angus, James A., Morrison, Wayne A.·2007·Circulation

Abstract

Background— Cardiac tissue engineering offers the prospect of a novel treatment for acquired or congenital heart defects. We have created vascularized pieces of beating cardiac muscle in the rat that are as thick as the adult rat right ventricle wall. Method and Results— Neonatal rat cardiomyocytes in Matrigel were implanted with an arteriovenous blood vessel loop into a 0.5-mL patented tissue-engineering chamber, located subcutaneously in the groin. Chambers were harvested 1, 4, and 10 weeks after insertion. At 4 and 10 weeks, all constructs that grew in the chambers contracted spontaneously. Immunostaining for α-sarcomeric actin, troponin, and desmin showed that differentiated cardiomyocytes present in tissue at all time points formed a network of interconnected cells within a collagenous extracellular matrix. Constructs at 4 and 10 weeks were extensively vascularized. The maximum thickness of cardiac tissue generated was 1983 μm. Cardiomyocytes increased in size from 1 to 10 weeks and were positive for the proliferation markers Ki67 and PCNA. Connexin-43 stain indicated that gap junctions were present between cardiomyocytes at 4 and 10 weeks. Echocardiograms performed between 4 and 10 weeks showed that the tissue construct contracted spontaneously in vivo. In vitro organ bath experiments showed a typical cardiac muscle length-tension relationship, the ability to be paced from electrical field pulses up to 3 Hz, positive chronotropy to norepinephrine, and positive inotropy in response to calcium. Conclusion— In summary, the use of a vascularized tissue-engineering chamber allowed generation of a spontaneously beating 3-dimensional mass of cardiac tissue from neonatal rat cardiomyocytes. Further development of this vascularized model will increase the potential of cardiac tissue engineering to provide suitable replacement tissues for acquired and congenital defects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.657379

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 221

Metadata

Authors
Morritt, A. N., Bortolotto, S. K., Dilley, R. J., Han, X., Kompa, A. R., McCombe, D., Wright, C. E., Itescu, S., Angus, J. A., & Morrison, W. A.
Venue
Circulation
Published
2007-01-23
Volume
115
Issue
3
Pages
353-360
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2129956520
Cited by
221
References
2
FWCI
17.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Tissue Engineering in an In Vivo Vascularized Chamber. https://app.cochat.ai/papers/10.1161/circulationaha.106.657379
The paper
Morritt, A. N., Bortolotto, S. K., Dilley, R. J., Han, X., Kompa, A. R., McCombe, D., Wright, C. E., Itescu, S., Angus, J. A., & Morrison, W. A. (2007). Cardiac Tissue Engineering in an In Vivo Vascularized Chamber. Circulation. https://doi.org/10.1161/circulationaha.106.657379

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.