CoChat

Myocardial Energetics and Efficiency: Current Status of the Noninvasive Approach

Open access
Knaapen, Paul, Germans, Tjeerd, Knuuti, Juhani, Paulus, Walter J., Dijkmans, Pieter A., Allaart, Cornelis P., Lammertsma, Adriaan A., Visser, Frans C. · 2007 · Circulation
Cited by 199

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

T he heart is an aerobic organ that relies almost exclusively on the aerobic oxidation of substrates for generation of energy.Consequently, there is close coupling between myocardial oxygen consumption (MV ˙O2 ) and the main determinants of systolic function: heart rate, contractile state, and wall stress. 1 As in any mechanical pump, only part of the energy invested is converted to external power.In the case of the heart, the ratio of useful energy produced (ie, stroke work [SW]) to oxygen consumed is defined as mechanical efficiency, as originally proposed by Bing et al. 2 Under normal conditions this ratio is Ϸ25%, and the residual energy mainly dissipates as heat.3 In pathophysiological disease states, such as heart failure, mechanical efficiency is reduced, and it has been hypothesized that the increased energy expenditure relative to work contributes to progression of the disease.4,5 Moreover, therapeutic interventions that enhance mechanical efficiency have proven to be beneficial with respect to outcome.6 It is therefore desirable to quantify efficiency of the heart to study disease processes and monitor interventions.Both cardiac oxidative metabolism and mechanical work, and thus efficiency, can be quantified through invasive measurements.Although these measurements are accurate and currently considered the gold standard, in clinical practice they are limited because of the need for dual-sided heart catheterization and selective catheterization of the coronary sinus.Recent advances in imaging techniques, however, offer the possibility to noninvasively estimate MV ˙O2 and mechanical work by positron emission tomography and echocardiography or by magnetic resonance imaging, respectively.This review discusses the principles of mechanical efficiency, together with its invasive and noninvasive assessment, as well as their strengths and pitfalls.Finally, results from clinical pathophysiological studies are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.660639

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

Metadata

Authors
Knaapen, P., Germans, T., Knuuti, J., Paulus, W. J., Dijkmans, P. A., Allaart, C. P., Lammertsma, A. A., & Visser, F. C.
Venue
Circulation
Published
2007-02-20
Volume
115
Issue
7
Pages
918-927
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2112637952
Cited by
199
References
41
FWCI
4.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.