Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 388

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Molecular Imaging of Inflammation in Atherosclerosis With Targeted Ultrasound Detection of Vascular Cell Adhesion Molecule-1

Kaufmann, Beat A., Sanders, John M., Davis, Christopher, Xie, Aris, Aldred, Patrick, Sarembock, Ian J., Lindner, Jonathan R. · 2007 · Circulation

Abstract

Background— The ability to image vascular inflammatory responses may allow early diagnosis and treatment of atherosclerosis. We hypothesized that molecular imaging of vascular cell adhesion molecule-1 (VCAM-1) expression with contrast-enhanced ultrasound (CEU) could be used for this purpose. Methods and Results— Attachment of VCAM-1–targeted and control microbubbles to cultured endothelial cells was assessed in a flow chamber at variable shear stress (0.5 to 12.0 dynes/cm 2 ). Microbubble attachment to aortic plaque was determined by en face microscopy of the thoracic aorta 10 minutes after intravenous injection in wild-type or apolipoprotein E–deficient mice on either chow or hypercholesterolemic diet. CEU molecular imaging of the thoracic aorta 10 minutes after intravenous microbubble injection was performed for the same animal groups. VCAM-1–targeted but not control microbubbles attached to cultured endothelial cells, although firm attachment at the highest shear rates (8 to 12 dynes/cm 2 ) occurred only in pulsatile flow conditions. Aortic attachment of microbubbles and targeted CEU signal was very low in control wild-type mice on chow diet. Aortic attachment of microbubbles and CEU signal for VCAM-1–targeted microbubbles differed between treatment groups according to extent of VCAM-1–positive plaque formation (median CEU videointensity, 1.8 [95% CI, 1.2 to 1.7], 3.7 [95% CI, 2.9 to 7.3], 6.8 [95% CI, 3.9 to 7.6], and 11.2 [95% CI, 8.5 to 16.0] for wild-type mice on chow and hypercholesterolemic diet and for apolipoprotein E–deficient mice on chow and hypercholesterolemic diet, respectively; P <0.001). Conclusions— CEU molecular imaging of VCAM-1 is capable of rapidly quantifying vascular inflammatory changes that occur in different stages of atherosclerosis. This method may be potentially useful for early risk stratification according to inflammatory phenotype.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.684738

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 388

Metadata

Authors
Kaufmann, B. A., Sanders, J. M., Davis, C., Xie, A., Aldred, P., Sarembock, I. J., & Lindner, J. R.
Venue
Circulation
Published
2007-07-17
Volume
116
Issue
3
Pages
276-284
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2100303262
Cited by
388
References
26
FWCI
24.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Molecular Imaging of Inflammation in Atherosclerosis With Targeted Ultrasound Detection of Vascular Cell Adhesion Molecule-1. https://app.cochat.ai/papers/10.1161/circulationaha.106.684738
The paper
Kaufmann, B. A., Sanders, J. M., Davis, C., Xie, A., Aldred, P., Sarembock, I. J., & Lindner, J. R. (2007). Molecular Imaging of Inflammation in Atherosclerosis With Targeted Ultrasound Detection of Vascular Cell Adhesion Molecule-1. Circulation. https://doi.org/10.1161/circulationaha.106.684738

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.