The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Outcomes of Left Ventricular Assist Device Implantation as Destination Therapy in the Post-REMATCH Era: Implications for Patient Selection
Open accessAbstract
Background— The landmark Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) trial first demonstrated that implantation of left ventricular assist devices (LVADs) as destination therapy (DT) can provide survival superior to any known medical treatment in patients with end-stage heart failure who are ineligible for transplantation. In the present study, we describe outcomes of DT in the post-REMATCH era in the United States. Methods and Results— The present study included 280 patients who underwent HeartMate XVE LVAD implantation between November 2001 and December 2005. A preoperative risk score for in-hospital mortality after LVAD implantation was established in 222 patients with complete data. All patients were followed up until death or December 2006. The 1-year survival after LVAD implantation was 56%. The in-hospital mortality after LVAD surgery was 27%. The main causes of death included sepsis, right heart failure, and multiorgan failure. The most important determinants of in-hospital mortality were poor nutrition, hematological abnormalities, markers of end-organ or right ventricular dysfunction, and lack of inotropic support. Stratification of DT candidates into low (n=65), medium (n=111), high (n=28), and very high (n=18) risk on the basis of the risk score calculated from these predictors corresponded with 1-year survival rates of 81%, 62%, 28%, and 11%, respectively. Conclusions— Appropriate selection of candidates and timing of LVAD implantation are critical for improved outcomes of DT. Patients with advanced heart failure who are referred for DT before major complications of heart failure develop have the best chance of achieving an excellent 1-year survival with LVAD therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
Self-citationThe Seattle Heart Failure Model: Prediction of Survival in Heart Failure
Levy, W. C., Mozaffarian, D., Linker, D. T., Sutradhar, S. C., Anker, S. D., Cropp, A. B., Anand, I., Maggioni, A., Burton, P., Sullivan, M. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.584102 · Cited by 2,021
Signal detection theory and ROC analysis
Egan, J. P. (1975) · Academic Press eBooks · Cited by 1,659
Best Subsets Logistic Regression
Hosmer, D. W., Jovanovic, B., & Lemeshow, S. (1989) · Biometrics · doi:10.2307/2531779 · Cited by 1,176
Deng, M. C., Edwards, L. B., Hertz, M. I., Rowe, A. W., Keck, B. M., Kormos, R., Naftel, D. C., Kirklin, J. K., & Taylor, D. O. (2005) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2005.07.002 · Cited by 348
Hunt, S. A., Baker, D. W., Chin, M. H., Cinquegrani, M. P., Feldman, A. M., Francis, G. S., Ganiats, T. G., Goldstein, S., Gregoratos, G., Jessup, M. L., et al. (2002) · The Journal of Heart and Lung Transplantation · doi:10.1016/s1053-2498(01)00776-8 · Cited by 285
Self-citationTaylor, D. O., Edwards, L. B., Boucek, M. M., Trulock, E. P., Keck, B. M., & Hertz, M. I. (2004) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2004.05.004 · Cited by 225
Stevenson, L. W., Miller, L. W., Desvigne-Nickens, P., Ascheim, D. D., Parides, M. K., Renlund, D. G., Oren, R. M., Krueger, S. K., Costanzo, M. R., Wann, L. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000139862.48167.23 · Cited by 206
Self-citationLeft ventricular assist device therapy improves utilization of donor hearts
Aaronson, K. D., Eppinger, M. J., Dyke, D. B. S., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01751-5 · Cited by 134
Predictive Performance of Ten Equations for Estimating Creatinine Clearance in Cardiac Patients
Spinler, S. A., Nawarskas, J. J., Boyce, E. G., Connors, J. E., Charland, S. L., Goldfarb, S., & The Iohexol Cooperative Study Group (1998) · Annals of Pharmacotherapy · doi:10.1345/aph.18122 · Cited by 93
Cited by
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Self-citation2005 WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192065 · Cited by 3,720
Self-citationAdvanced heart failure treated with continuous-flow left ventricular assist device
Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0909938 · Cited by 3,063
Self-citation2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Self-citationUse of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Self-citation
Metadata
- Authors
- Lietz, K., Long, J. W., Kfoury, A. G., Slaughter, M. S., Silver, M. A., Milano, C. A., Rogers, J. G., Naka, Y., Mancini, D., & Miller, L. W.
- Venue
- Circulation
- Published
- 2007-07-31
- Volume
- 116
- Issue
- 5
- Pages
- 497-505
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1997701104
- Cited by
- 755
- References
- 16
- FWCI
- 44.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.