Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 328

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy: Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation

Open access
Dewey, Marc, Zimmermann, Elke, Deissenrieder, Florian, Laule, Michael, Dübel, Hans-Peter, Schlattmann, Peter, Knebel, Fabian, Rutsch, Wolfgang, Hamm, Bernd·2009·Circulation

Abstract

Background— Noninvasive coronary angiography with the use of multislice computed tomography (CT) scanners is feasible with high sensitivity and negative predictive value; however, the radiation exposure associated with this technique is rather high. We evaluated coronary angiography using whole-heart 320-row CT, which avoids exposure-intensive overscanning and overranging. Methods and Results— A total of 30 consecutive patients with suspected coronary artery disease referred for clinically indicated conventional coronary angiography (CCA) were included in this prospective intention-to-diagnose study. CT was performed with the use of up to 320 simultaneous detector rows before same-day CCA, which, together with quantitative analysis, served as the reference standard. The per-patient sensitivity and specificity for CT compared with CCA were 100% (95% confidence interval [CI], 72 to 100) and 94% (95% CI, 73 to 100), respectively. Per-vessel versus per-segment sensitivity and specificity were 89% (95% CI, 62 to 98) and 96% (95% CI, 90 to 99) versus 78% (95% CI, 56 to 91) and 98% (95% CI, 96 to 99), respectively. Interobserver agreement between the 2 readers was significantly better for CCA (97% of 121 coronary arteries) than for CT (90%; P =0.04). Percent diameter stenosis determined with the use of CT showed good correlation with CCA ( P <0.001, R =0.81) without significant underestimation or overestimation (−3.1±24.4%; P =0.08). Intraindividual comparison of CT with CCA revealed a significantly smaller effective radiation dose (median, 4.2 versus 8.5 mSv; P <0.05) and amount of contrast agent required (median, 80 versus 111 mL; P <0.001) for 320-row CT. The majority of patients (87%) indicated that they would prefer CT over CCA for future diagnostic imaging ( P <0.001). Conclusions— CT with the use of emerging technology has the potential to significantly reduce the radiation dose and amount of contrast agent required compared with CCA while maintaining high diagnostic accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.109.859280

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Metadata

Authors
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B.
Venue
Circulation
Published
2009-09-08
Volume
120
Issue
10
Pages
867-875
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1979043393
Cited by
328
References
40
FWCI
36.64
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy: Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation. https://app.cochat.ai/papers/10.1161/circulationaha.109.859280
The paper
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B. (2009). Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy: Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation. Circulation. https://doi.org/10.1161/circulationaha.109.859280

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.