The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves
Open accessAbstract
Background— Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. Methods and Results— In 564 patients (mean age, 74±5 years) receiving an aortic valve bioprosthesis, clinical follow-up (median, 6.1 years; maximum, 16.4 years) was analyzed including echocardiography. SVD was diagnosed in 40 patients (7%) as substantially increased stenosis (n=24) or regurgitation (n=16) of the operated valve over time. When patients with P-PtM (effective orifice area index <0.85 cm 2 /m 2 ; n=285) developed SVD, it was preferentially of the stenosis type, whereas when patients without P-PtM (n=279) developed SVD, the majority was of the incompetence type ( P <0.05). Multivariable analysis including patient- and valve-related variables revealed that P-PtM and label size ≤21 were independent predictors of SVD ( P =0.04 and P =0.02, respectively). A nonparametric Turnbull estimate analysis showed that SVD is virtually nonexistent for up to 9 years in patients without P-PtM. Thereafter, SVD starts to occur and is mainly of the incompetence-type SVD (79% of cases). In patients with P-PtM, SVD starts to occur after 2 to 3 years after implantation and is mainly of the stenosis-type SVD (81% of cases). Conclusions— These data suggest that stenosis-type SVD is an early, P-PtM–related, and thus preventable phenomenon. Incompetence-type SVD is a time-dependent, nonspecific wear damage to bioprosthetic valves, which is not related to P-PtM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The problem of valve prosthesis-patient mismatch.
Rahimtoola, S. H. (1978) · Circulation · doi:10.1161/01.cir.58.1.20 · Cited by 853
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Pibarot, P., & Dumesnil, J. G. (2009) · Circulation · doi:10.1161/circulationaha.108.778886 · Cited by 786
Pibarot, P., & Dumesnil, J. G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00859-7 · Cited by 674
Guidelines for reporting mortality and morbidity after cardiac valve interventions
Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., Takkenberg, J. J. M., David, T. E., Butchart, E. G., Adams, D. H., et al. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.12.002 · Cited by 665
Impact of Valve Prosthesis-Patient Mismatch on Short-Term Mortality After Aortic Valve Replacement
Blais, C., Dumesnil, J. G., Baillot, R., Simard, S., Doyle, D., & Pibarot, P. (2003) · Circulation · doi:10.1161/01.cir.0000085167.67105.32 · Cited by 564
Choice of prosthetic heart valve for adult patients
Rahimtoola, S. H. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02965-0 · Cited by 302
Impact of Prosthesis-Patient Mismatch on Long-Term Survival After Aortic Valve Replacement
Mohty, D., Dumesnil, J. G., Echahidi, N., Mathieu, P., Dagenais, F., Voisine, P., & Pibarot, P. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.09.022 · Cited by 255
Mohty-Echahidi, D., Malouf, J. F., Girard, S. E., Schaff, H. V., Grill, D. E., Enriquez-Sarano, M. E., & Miller, F. A. (2006) · Circulation · doi:10.1161/circulationaha.105.546754 · Cited by 214
Survival after valve replacement for aortic stenosis: Implications for decision making
Mihaljevic, T., Nowicki, E. R., Rajeswaran, J., Blackstone, E. H., Lagazzi, L., Thomas, J., Lytle, B. W., & Cosgrove, D. M. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.12.042 · Cited by 208
Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆
WALTHER, T., RASTAN, A., FALK, V, LEHMANN, S., GARBADE, J., FUNKAT, A., MOHR, F., & GUMMERT, J. (2006) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.04.007 · Cited by 186
Cited by
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Beyersdorf, F., Vahanian, A., Milojevic, M., Praz, F., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2021) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezab389 · Cited by 622
Lancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567
Head, S. J., Mokhles, M. M., Osnabrugge, R. L. J., Pibarot, P., Mack, M. J., Takkenberg, J. J. M., Bogers, A. J. J. C., & Kappetein, A. P. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs003 · Cited by 522
Long-Term Durability of Bioprosthetic Aortic Valves: Implications From 12,569 Implants
Johnston, D. R., Soltesz, E. G., Vakil, N., Rajeswaran, J., Roselli, E. E., Sabik, J. F., Smedira, N. G., Svensson, L. G., Lytle, B. W., & Blackstone, E. H. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2014.10.070 · Cited by 488
Dvir, D., Bourguignon, T., Otto, C. M., Hahn, R. T., Rosenhek, R., Webb, J. G., Treede, H., Sarano, M. E., Feldman, T., Wijeysundera, H. C., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030729 · Cited by 479
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · EuroIntervention · doi:10.4244/eij-e-21-00009 · Cited by 372
Aortic Bioprosthetic Valve Durability
Rodriguez-Gabella, T., Voisine, P., Puri, R., Pibarot, P., & Rodés-Cabau, J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.715 · Cited by 351
Degeneration of Bioprosthetic Heart Valves: Update 2020
Kostyunin, A. E., Yuzhalin, A. E., Rezvova, M. A., Ovcharenko, E. A., Glushkova, T. V., & Kutikhin, A. G. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.120.018506 · Cited by 347
Prosthesis–Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement
Herrmann, H. C., Daneshvar, S. A., Fonarow, G. C., Stebbins, A., Vemulapalli, S., Desai, N. D., Malenka, D. J., Thourani, V. H., Rymer, J., & Kosinski, A. S. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.001 · Cited by 336
The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement
Fallon, J. M., DeSimone, J. P., Brennan, J. M., O’Brien, S., Thibault, D. P., DiScipio, A. W., Pibarot, P., Jacobs, J. P., & Malenka, D. J. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.01.090 · Cited by 257
Metadata
- Authors
- Flameng, W., Herregods, M.-C., Vercalsteren, M., Herijgers, P., Bogaerts, K., & Meuris, B.
- Venue
- Circulation
- Published
- 2010-05-18
- Volume
- 121
- Issue
- 19
- Pages
- 2123-2129
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2072848168
- Cited by
- 309
- References
- 26
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.