The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Transcatheter Valve-in-Valve Implantation for Failed Bioprosthetic Heart Valves
Abstract
Background— The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a “valve-in-valve” procedure, may offer a less invasive alternative. Methods and Results— Valve-in-valve implantations were performed in 24 high-risk patients. Failed valves were aortic (n=10), mitral (n=7), pulmonary (n=6), or tricuspid (n=1) bioprostheses. Implantation was successful with immediate restoration of satisfactory valve function in all but 1 patient. No patient had more than mild regurgitation after implantation. No patients died during the procedure. Thirty-day mortality was 4.2%. Mortality was related primarily to learning-curve issues early in this high-risk experience. At baseline, 88% of patients were in New York Heart Association functional class III or IV; at the last follow-up, 88% of patients were in class I or II. At a median follow-up of 135 days (interquartile range, 46 to 254 days) and a maximum follow-up of 1045 days, 91.7% of patients remained alive with satisfactory valve function. Conclusions— Transcatheter valve-in-valve implantation is a reproducible option for the management of bioprosthetic valve failure. Aortic, pulmonary, mitral, and tricuspid tissue valves were amenable to this approach. This finding may have important implications with regard to valve replacement in high-risk patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O'Gara, P. T., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.007 · Cited by 2,257
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Transcatheter Aortic Valve Implantation: Impact on Clinical and Valve-Related Outcomes
Webb, J. G., Altwegg, L., Boone, R. H., Cheung, A., Ye, J., Lichtenstein, S., Lee, M., Masson, J. B., Thompson, C., Moss, R., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.837807 · Cited by 589
Self-citationPercutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients
Khambadkone, S., Coats, L., Taylor, A., Boudjemline, Y., Derrick, G., Tsang, V., Cooper, J., Muthurangu, V., Hegde, S. R., Razavi, R. S., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.523266 · Cited by 459
Clavel, M.-A., Webb, J. G., Pibarot, P., Altwegg, L., Dumont, E., Thompson, C., De Larochellière, R., Doyle, D., Masson, J.-B., Bergeron, S., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.01.060 · Cited by 389
Self-citationPiazza, N., Onuma, Y., Jesserun, E., Kint, P. P., Maugenest, A.-M., Anderson, R. H., de Jaegere, P. P. T., & Serruys, P. W. (2008) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2008.04.007 · Cited by 346
Percutaneous insertion of the pulmonary valve
Bonhoeffer, P., Boudjemline, Y., Qureshi, S. A., Le Bidois, J., Iserin, L., Acar, P., Merckx, J., Kachaner, J., & Sidi, D. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01822-3 · Cited by 307
Guidelines for reporting mortality and morbidity after cardiac valve interventions
Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., Takkenberg, J. J. M., David, T. E., Butchart, E. G., Adams, D. H., et al. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2007.12.055 · Cited by 289
Repeat heart valve surgery: Risk factors for operative mortality
Jones, J. M., O'Kane, H., Gladstone, D. J., Sarsam, M. A. I., Campalani, G., MacGowan, S. W., Cleland, J., & Cran, G. W. (2001) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.116470 · Cited by 254
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Fleisher, L. A., Jneid, H., Mack, M. J., McLeod, C. J., O’Gara, P. T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.011 · Cited by 3,339
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Fleisher, L. A., Jneid, H., Mack, M. J., McLeod, C. J., O’Gara, P. T., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000503 · Cited by 2,497
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000932 · Cited by 2,449
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs455 · Cited by 2,009
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.035 · Cited by 1,075
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
“Stenosis (n = 181) Regurgitation (n = 139) Combined (n = 139) P Value SelfExpandable (n = 213) BalloonExpandable (n = 246) P Value Time since last SAVR, median (IQR), ya 9 (6-12) 8 (5-11) 10(7-14) 10 (7-14) .”
Self-citation2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Dvir, D., Webb, J., Brecker, S., Bleiziffer, S., Hildick-Smith, D., Colombo, A., Descoutures, F., Hengstenberg, C., Moat, N. E., Bekeredjian, R., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.104505 · Cited by 583
Self-citationAortic Bioprosthetic Valve Durability
Rodriguez-Gabella, T., Voisine, P., Puri, R., Pibarot, P., & Rodés-Cabau, J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.715 · Cited by 351
Transcatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
“Several reports have shown the feasibility of TAVI for the treatment of surgical bioprosthesis dysfunction, including of stented and stentless valves, which opens up a new avenue for the treatment of this challenging group of patients”
BackgroundSelf-citation2020 ACC/AHA guideline for the management of patients with valvular heart disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2021.04.002 · Cited by 279
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B., Lamm, D., O'Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 252
Metadata
- Authors
- Webb, J. G., Wood, D. A., Ye, J., Gurvitch, R., Masson, J.-B., Rodés-Cabau, J., Osten, M., Horlick, E., Wendler, O., Dumont, E., Carere, R. G., Wijesinghe, N., Nietlispach, F., Johnson, M., Thompson, C. R., Moss, R., Leipsic, J., Munt, B., Lichtenstein, S. V., & Cheung, A.
- Venue
- Circulation
- Published
- 2010-04-27
- Volume
- 121
- Issue
- 16
- Pages
- 1848-1857
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2000871092
- Cited by
- 508
- References
- 19
- FWCI
- 48.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.