The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Permanent Pacemaker Insertion After CoreValve Transcatheter Aortic Valve Implantation: Incidence and Contributing Factors (the UK CoreValve Collaborative)
Abstract
Background—: Permanent pacemaker (PPM) requirement is a recognized complication of transcatheter aortic valve implantation. We assessed the UK incidence of permanent pacing within 30 days of CoreValve implantation and formulated an anatomic and electrophysiological model. Methods and Results—: Data from 270 patients at 10 centers in the United Kingdom were examined. Twenty-five patients (8%) had preexisting PPMs; 2 patients had incomplete data. The remaining 243 were 81.3±6.7 years of age; 50.6% were male. QRS duration increased from 105±23 to 135±29 milliseconds ( P <0.01). Left bundle-branch block incidence was 13% at baseline and 61% after the procedure ( P <0.001). Eighty-one patients (33.3%) required a PPM within 30 days. Rates of pacing according to preexisting ECG abnormalities were as follows: right bundle-branch block, 65.2%; left bundle-branch block, 43.75%; normal QRS, 27.6%. Among patients who required PPM implantation, the median time to insertion was 4.0 days (interquartile range, 2.0 to 7.75 days). Multivariable analysis revealed that periprocedural atrioventricular block (odds ratio, 6.29; 95% confidence interval, 3.55 to 11.15), balloon predilatation (odds ratio, 2.68; 95% confidence interval, 2.00 to 3.47), use of the larger (29 mm) CoreValve prosthesis (odds ratio, 2.50; 95% confidence interval, 1.22 to 5.11), interventricular septum diameter (odds ratio, 1.18; 95% confidence interval, 1.10 to 3.06), and prolonged QRS duration (odds ratio, 3.45; 95% confidence interval, 1.61 to 7.40) were independently associated with the need for PPM. Conclusion—: One third of patients undergoing a CoreValve transcatheter aortic valve implantation procedure require a PPM within 30 days. Periprocedural atrioventricular block, balloon predilatation, use of the larger CoreValve prosthesis, increased interventricular septum diameter and prolonged QRS duration were associated with the need for PPM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Authors/Task Force Members, Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl428 · Cited by 3,593
Iung, B. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00201-x · Cited by 3,530
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Clinical Factors Associated With Calcific Aortic Valve Disease
Stewart, B. F., Siscovick, D., Lind, B. K., Gardin, J. M., Gottdiener, J. S., Smith, V. E., Kitzman, D. W., & Otto, C. M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00563-3 · Cited by 2,029
ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.021 · Cited by 1,702
Association of Aortic-Valve Sclerosis with Cardiovascular Mortality and Morbidity in the Elderly
Otto, C. M., Lind, B. K., Kitzman, D. W., Gersh, B. J., & Siscovick, D. S. (1999) · New England Journal of Medicine · doi:10.1056/nejm199907153410302 · Cited by 1,283
Lindroos, M., Kupari, M., Heikkilä, J., & Tilvis, R. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90249-z · Cited by 1,160
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Grube, E., Schuler, G., Buellesfeld, L., Gerckens, U., Linke, A., Wenaweser, P., Sauren, B., Mohr, F.-W., Walther, T., Zickmann, B., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.047 · Cited by 959
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Grube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.639450 · Cited by 655
Self-citationNoninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518
Adjustments for Center in Multicenter Studies: An Overview
Localio, A. R., Berlin, J. A., Ten Have, T. R., & Kimmel, S. E. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00012 · Cited by 442
Piazza, N., Onuma, Y., Jesserun, E., Kint, P. P., Maugenest, A.-M., Anderson, R. H., de Jaegere, P. P. T., & Serruys, P. W. (2008) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2008.04.007 · Cited by 346
Guidelines on the management of valvular heart disease: reply
Vahanian, P. A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm095 · Cited by 301
Grube, E., Laborde, J. C., Zickmann, B., Gerckens, U., Felderhoff, T., Sauren, B., Bootsveld, A., Buellesfeld, L., & Iversen, S. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20544 · Cited by 251
Self-citationIs It Reasonable to Treat All Calcified Stenotic Aortic Valves With a Valved Stent?
Zegdi, R., Ciobotaru, V., Noghin, M., Sleilaty, G., Lafont, A., Latrémouille, C., Deloche, A., & Fabiani, J.-N. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.023 · Cited by 245
Dawkins, S., Hobson, A. R., Kalra, P. R., Tang, A. T. M., Monro, J. L., & Dawkins, K. D. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.08.024 · Cited by 209
Jilaihawi, H., Chin, D., Vasa-Nicotera, M., Jeilan, M., Spyt, T., Ng, G. A., Bence, J., Logtens, E., & Kovac, J. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.02.016 · Cited by 200
Limongelli, G., Ducceschi, V., D’Andrea, A., et al. (2003) · Heart · doi:10.1136/heart.89.8.901 · Cited by 154
Poh, K. K., Levine, R. A., Solı́s, J., Shen, L., Flaherty, M., Kang, Y.-J., Guerrero, J. L., & Hung, J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn022 · Cited by 136
Prognostic significance of newly acquired bundle branch block after aortic valve replacement
El-Khally, Z., Thibault, B., Staniloae, C. S., Théroux, P., Dubuc, M., Roy, D., Guerra, P. G., Macle, L., & Talajic, M. R. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.06.055 · Cited by 122
Permanent cardiac pacing after a cardiac operation: Predicting the use of permanent pacemakers
Gordon, R. S., Ivanov, J., Cohen, G. N., & Ralph-Edwards, A. L. (1998) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(98)00889-3 · Cited by 121
Risk Factors for Requirement of Permanent Pacemaker Implantation After Aortic Valve Replacement
Erdoğan, H. B., Kayalar, N., Ardal, H., Ömeroğlu, S. N., Kırali, K., Güler, M., Akıncı, E., & Yakut, C. (2006) · Journal of Cardiac Surgery · doi:10.1111/j.1540-8191.2006.00216.x · Cited by 120
Quality of life assessment after percutaneous aortic valve implantation
Ussia, G. P., Mulè, M., Barbanti, M., Cammalleri, V., Scarabelli, M., Immè, S., Capodanno, D., Ciriminna, S., & Tamburino, C. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp171 · Cited by 92
Kapadia, S. R., Goel, S. S., Svensson, L. G., Roselli, E. E., Savage, R. M., Wallace, L., Sola, S., Schoenhagen, P., Shishehbor, M. H., Christofferson, R. D., et al. (2009) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.12.030 · Cited by 89
High-Risk Patients Referred for Transcatheter Aortic Valve Implantation: Management and Outcomes
Dewey, T. M., Brown, D. L., Das, T. S., Ryan, W. H., Fowler, J., Hoffman, S., Prince, S. L., Herbert, M. A., Culica, D. V., & Mack, M. J. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.07.043 · Cited by 68
McKay, R. G., Safian, R. D., Berman, A. D., et al. (1987) · Circulation · doi:10.1161/01.cir.76.6.1298 · Cited by 28
Percutaneous Aortic Valve Replacement With the CoreValve Prosthesis
Zegdi, R., Sleilaty, G., Lafont, A. M., & Fabiani, J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.089 · Cited by 17
Segers, P., Fostier, G., Neckebroeck, J., & Verdonck, P. (1999) · Catheterization and Cardiovascular Interventions · doi:10.1002/(sici)1522-726x(199903)46:3<380::aid-ccd27>3.0.co;2-j · Cited by 17
Cited by
Popma, J. J., Adams, D. H., Reardon, M. J., Yakubov, S. J., Kleiman, N. S., Heimansohn, D., Hermiller, J., Hughes, G. C., Harrison, J. K., Coselli, J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.556 · Cited by 1,040
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Self-citation2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Siontis, G. C. M., Jüni, P., Pilgrim, T., Stortecky, S., Büllesfeld, L., Meier, B., Wenaweser, P., & Windecker, S. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.033 · Cited by 647
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Metadata
- Authors
- Khawaja, M. Z., Rajani, R., Cook, A., Khavandi, A., Moynagh, A., Chowdhary, S., Spence, M. S., Brown, S., Khan, S. Q., Walker, N., Trivedi, U., Hutchinson, N., De Belder, A. J., Moat, N., Blackman, D. J., Levy, R. D., Manoharan, G., Roberts, D., Khogali, S. S., Crean, P., Brecker, S. J., Baumbach, A., Mullen, M., Laborde, J.-C., & Hildick-Smith, D.
- Venue
- Circulation
- Published
- 2011-03-08
- Volume
- 123
- Issue
- 9
- Pages
- 951-960
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2022851384
- Cited by
- 313
- References
- 31
- FWCI
- 32.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.